Flashcards With Solved Solutions 2024
This type of water heater ventilation system uses the natural upward movement of
airflow to filter exhaust gases up and out of the home. - CORRECT ANSWER-
atmospheric ventilation system
The shutoff valve for a gas water heater's supply line may not be more than _____ feet
from the water heater. - CORRECT ANSWER-6
Water heaters must be installed in a location that has a level working space that is at
least _____ inches long and _____ inches wide. - CORRECT ANSWER-30, 30
Water heaters that use a gas fuel source may not be located in a room with _____
machinery. - CORRECT ANSWER-air-handling
Chimney Cap - CORRECT ANSWER-mounted above the crown, preventing water,
birds, small animals, and debris from getting inside the chimney while allowing smoke
and gas to escape.
Chimney Crown - CORRECT ANSWER-the top level of the chimney, with a sloped
surface directing much of the water away from the chimney
Spark arrestor - CORRECT ANSWER-mesh covering that stops sparks and embers
from leaving the chimney.
Irrigation systems conserve water by the use ___ ____ or ___ ___ sensors (SMS). -
CORRECT ANSWER-rain sensors, soil moisture
What 2 components are in a zone for a sprinkler system? - CORRECT ANSWER-valve,
sprinkler head
, What is a backflow preventor? - CORRECT ANSWER-Stops water contaminated from
pesticides, fertilizers, or other chemicals from entering the home's supply of drinking
water by allowing water to flow only one way
What are 2 possible locations for the irrigation system's shut-off valve? - CORRECT
ANSWER-below backflow preventor or underground, in line with water supply
Four types of well pumps: - CORRECT ANSWER-shallow well jet, centrifugal, deep well
jet, deep well submersible
Pressure switch - CORRECT ANSWER-senses water pressure and turns the pump off
and on and is normally mounted on piping at the water pressure tank.
Two types of septic systems: - CORRECT ANSWER-conventional, alternative
In a conventional septic system, sludge and scum remain in the tank, and the liquid
called ____ leaves the tank. - CORRECT ANSWER-effluent
A ___ ___ is a network of perforated pipes in trenches or beds of gravel. - CORRECT
ANSWER-drain field
For ranges, vent hood ducts must (3): ___, ___, and ___. - CORRECT ANSWER-
terminate outside the home, have a smooth interior surface and be constructed of
(galvanized steel, stainless steel, or copper), and be airtight
What 3 things can prevent cross connections at some equipment and fixtures: -
CORRECT ANSWER-anti-siphon devices, vacuum breakers, air gaps
S-traps can be converted to a vented P-trap through the use of an: - CORRECT
ANSWER-air admittance valve
This type of meter was installed in the last 20 years. They're usually compatible with
200 amp service, although there are exceptions. - CORRECT ANSWER-Rectangular-
base meters