100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

ACI Certification (Written test) ASTM C173 Volumetric

Rating
-
Sold
-
Pages
3
Grade
A+
Uploaded on
06-08-2024
Written in
2024/2025

ACI Certification (Written test) ASTM C173 Volumetric the volumetric method of determining air content of concrete can be used on concrete containing what type of aggregate? all types of aggregates what are the requirements for the tamping rod used in this test method round, straight, 5/8, hemispherical what are the requirements for the strike of bar used in this test method flat steel, 1/8 x 3/4 x 12 in, made of high density polyethylene what is the approximate volume of the measuring cup used to add water to the air meter, in relation to the volume of the air meter bowl? 1.0 +- 0.04% what type of alcohol and concentration must be used in this test method 70% isopropyl a mallet weighing lbs must be used to tap the sides of the bowl after rodding each layer 1.25 +- 0.5 the sample of concrete used in this test method must be obtained in accordance with what astm practice C172 the maximum size aggregate allowed in this test method is 1 - 1/2" if the concrete sample contains aggregate larger than that allowed for this test, the sample must be wet sieved over 1" when filling the measuring bowl of the air meter, the concrete must be placed in 2 layers what is the specified number of stroke required when rodding each layer of concrete? 25 it is necessary to tap the sides of the measuring bowl after each layer has been rodded. True the initial quantity of water and alcohol added to air meter can be poured directly into the neck of the top section of the air meter. false Upon final filling of the air meter with water, what part of the liquid level should be adjusted to teh zero mark on the meter? Bottom of the meniscus how long should the air meter be inverted and agitated 45 sec, but no more than 5 sec @ a time how many times does the rolling operation occur? must 2x but can be 3x Why is the isopropyl alcohol added to the meter? to dispel any foam the direct reading of the final liquid level, in the neck of the air meter, is estimated to the nearest .25% is the air content is greater than the 9% range of the meter add water with calibrated cup in order for an initial meter reading to be valid, the meter must not be leaking, the liquid level must be stabilized within 6 min, and the foam on the surface of the liquid must not be greater than 2 full percent divisions. true if less than 1.25 L [2.5 pt] of alcohol are used, the air content is always indicated by the final meter reading. false If more than 1.25 L [2.5 pt] of alcohol are used, the final meter reading is always adjusted using _________. a correction factor When large amounts of alcohol are used, the direct reading will tend to indicate a _____ air content. higher at the end of the procedure, the air meter is disassemble and examine content If portions of undisturbed concrete are found in the air meter at the end of the test, _____. the test is invalid

Show more Read less








Whoops! We can’t load your doc right now. Try again or contact support.

Document information

Uploaded on
August 6, 2024
Number of pages
3
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

ACI Certification (Written test) ASTM C173 Volumetric
the volumetric method of determining air content of concrete can be used on concrete containing what
type of aggregate?

all types of aggregates

what are the requirements for the tamping rod used in this test method

round, straight, 5/8, hemispherical

what are the requirements for the strike of bar used in this test method

flat steel, 1/8 x 3/4 x 12 in, made of high density polyethylene

what is the approximate volume of the measuring cup used to add water to the air meter, in relation to
the volume of the air meter bowl?

1.0 +- 0.04%

what type of alcohol and concentration must be used in this test method

70% isopropyl

a mallet weighing lbs must be used to tap the sides of the bowl after rodding each layer

1.25 +- 0.5

the sample of concrete used in this test method must be obtained in accordance with what astm
practice

C172

the maximum size aggregate allowed in this test method is

1 - 1/2"

if the concrete sample contains aggregate larger than that allowed for this test, the sample must be

wet sieved over 1"

when filling the measuring bowl of the air meter, the concrete must be placed in

2 layers

what is the specified number of stroke required when rodding each layer of concrete?

25

it is necessary to tap the sides of the measuring bowl after each layer has been rodded.

True

the initial quantity of water and alcohol added to air meter can be poured directly into the neck of the
top section of the air meter.

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
bestscores1 Kent State University
View profile
Follow You need to be logged in order to follow users or courses
Sold
12
Member since
1 year
Number of followers
0
Documents
1369
Last sold
1 month ago
ReadEase

Welcome to ReadEase, your ultimate resource for exam preparation. At ReadEase, we specialize in providing comprehensive study materials and resources to help you excel in your exams. Whether you're preparing for standardized tests, professional certifications, or academic assessments, our finely curated collection covers a wide range of subjects and levels. From practice tests and study guides to expert tips and strategies, we're here to support your journey to success. ReadEase is committed to availing high-quality educational content, helping you thrive and achieve your academic and professional goals. Have any questions? We're just a message away.

Read more Read less
4.3

4 reviews

5
2
4
1
3
1
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Frequently asked questions