100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

ACI Concrete Field Testing Technician - Grade I

Rating
-
Sold
-
Pages
7
Grade
A+
Uploaded on
06-08-2024
Written in
2024/2025

ACI Concrete Field Testing Technician - Grade I Temperature Measurement of Freshly Mixed Concrete - What is the minimum depth the sensing end of the temperature measuring device should be submerged in freshly mixed concrete? The end of the temperature sensing part must be submerged at least 77 mm (3 in.) into the concrete. - What is the accuracy and range requirement for the temperature measuring device? The device must accurately measure the temperature of freshly mixed concrete to within ±0.5°C (±1°F) over a range of 0-50°C. - How often should the temperature measuring device be verified? Verification of the temperature measuring device should occur annually or whenever there are questions regarding its accuracy. - Is it true that the temperature of concrete can be measured while it is in a wheelbarrow? True. The temperature can indeed be assessed in a wheelbarrow. - Can the temperature be measured in a wall form? True. It is permissible to measure the temperature of concrete within a wall form. - Is a composite sample necessary if the sole purpose is to measure temperature? False. A composite sample is not required just for temperature determination. - What preparation is needed for the sample container before sampling? The sample container must be dampened with water before the concrete is collected. - What should be done to the concrete around the temperature measuring device after it has been submerged? The concrete at the surface around the device should be gently pressed to ensure proper contact. - For how long must the temperature measuring device stay in the concrete for accurate measurement? The device should remain in the freshly mixed concrete for at least 2 minutes, but no more than 5 minutes. - What must be done after the concrete temperature is measured? The temperature must be reported following the measurement. - To what degree of precision should the concrete temperature be recorded? The temperature is reported to the nearest 1 degree Fahrenheit. - What is one reason given in ASTM C1064 for measuring concrete’s temperature? One key reason is to verify compliance with specific requirements. - Does ASTM C1064 specify a maximum allowable temperature for freshly mixed concrete? False. There is no maximum temperature limit specified in ASTM C1064. - Is it correct that a sample of concrete used for temperature evaluation must be rodded 25 times? False. There is no requirement for the sample to be rodded 25 times for temperature measurement. Sampling Procedures for Freshly Mixed Concrete - What is the purpose of sampling according to ASTM C172? The methods included aim to obtain representative samples for testing compliance with quality requirements of the relevant specifications. - From what types of mixers does this method cover sampling procedures? It applies to stationary mixers, paving mixers, revolving drum mixers, and open top mixers. - What is the maximum time allowed between taking the first and last portions of a composite sample? The elapsed time between these two portions must not exceed 15 minutes. - Should portions of a composite sample be mixed thoroughly before testing? True. Thorough mixing is required before any tests are conducted on the sample. - How quickly should tests for slump, temperature, and air content begin after taking the final portion of the composite sample? Tests should start within 5 minutes after obtaining the final portion. - When should specimen molding for strength tests commence after preparing the composite sample? Molding of the specimens must begin within 15 minutes after the composite sample is fabricated. - What precautions should be taken regarding the concrete sample? The sample must be protected from contamination and rapid evaporation. - What is the maximum volume for a concrete sample used in making strength test specimens? The minimum size required for strength test specimens is 1 cubic foot. - How many times should a batch from a stationary mixer be sampled during discharge? A batch must be sampled at two or more regularly spaced intervals during the discharge of its middle portion. When sampling from a PAVING mixer, obtain samples from at least __ different portions of the pile and combine them into one composite sample for test purposes 5 When sampling from a REVOLVING DRUM TRUCK mixer, sample the concrete by collecting __ or more portions taken at regularly spaced intervals during discharge of the middle portion of the batch. 2 Concrete samples from a truck mixer will be obtained before any water or admixtures are added to the

Show more Read less









Whoops! We can’t load your doc right now. Try again or contact support.

Document information

Uploaded on
August 6, 2024
Number of pages
7
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

ACI Concrete Field Testing Technician - Grade I


Temperature Measurement of Freshly Mixed Concrete



- What is the minimum depth the sensing end of the temperature measuring device should be
submerged in freshly mixed concrete?

The end of the temperature sensing part must be submerged at least 77 mm (3 in.) into the concrete.



- What is the accuracy and range requirement for the temperature measuring device?

The device must accurately measure the temperature of freshly mixed concrete to within ±0.5°C (±1°F)
over a range of 0-50°C.



- How often should the temperature measuring device be verified?

Verification of the temperature measuring device should occur annually or whenever there are
questions regarding its accuracy.



- Is it true that the temperature of concrete can be measured while it is in a wheelbarrow?

True. The temperature can indeed be assessed in a wheelbarrow.



- Can the temperature be measured in a wall form?

True. It is permissible to measure the temperature of concrete within a wall form.



- Is a composite sample necessary if the sole purpose is to measure temperature?

False. A composite sample is not required just for temperature determination.



- What preparation is needed for the sample container before sampling?

The sample container must be dampened with water before the concrete is collected.



- What should be done to the concrete around the temperature measuring device after it has been
submerged?

, The concrete at the surface around the device should be gently pressed to ensure proper contact.



- For how long must the temperature measuring device stay in the concrete for accurate measurement?

The device should remain in the freshly mixed concrete for at least 2 minutes, but no more than 5
minutes.



- What must be done after the concrete temperature is measured?

The temperature must be reported following the measurement.



- To what degree of precision should the concrete temperature be recorded?

The temperature is reported to the nearest 1 degree Fahrenheit.



- What is one reason given in ASTM C1064 for measuring concrete’s temperature?

One key reason is to verify compliance with specific requirements.



- Does ASTM C1064 specify a maximum allowable temperature for freshly mixed concrete?

False. There is no maximum temperature limit specified in ASTM C1064.



- Is it correct that a sample of concrete used for temperature evaluation must be rodded 25 times?

False. There is no requirement for the sample to be rodded 25 times for temperature measurement.



Sampling Procedures for Freshly Mixed Concrete



- What is the purpose of sampling according to ASTM C172?

The methods included aim to obtain representative samples for testing compliance with quality
requirements of the relevant specifications.



- From what types of mixers does this method cover sampling procedures?

It applies to stationary mixers, paving mixers, revolving drum mixers, and open top mixers.

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
bestscores1 Kent State University
View profile
Follow You need to be logged in order to follow users or courses
Sold
12
Member since
1 year
Number of followers
0
Documents
1369
Last sold
1 month ago
ReadEase

Welcome to ReadEase, your ultimate resource for exam preparation. At ReadEase, we specialize in providing comprehensive study materials and resources to help you excel in your exams. Whether you're preparing for standardized tests, professional certifications, or academic assessments, our finely curated collection covers a wide range of subjects and levels. From practice tests and study guides to expert tips and strategies, we're here to support your journey to success. ReadEase is committed to availing high-quality educational content, helping you thrive and achieve your academic and professional goals. Have any questions? We're just a message away.

Read more Read less
4.3

4 reviews

5
2
4
1
3
1
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Frequently asked questions