100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

4.1 Designing Vapor Distribution Systems Questions with 100% Actual correct answers | verified | latest update | Graded A+ | Already Passed | Complete Solution

Rating
-
Sold
-
Pages
26
Grade
A+
Uploaded on
19-06-2024
Written in
2023/2024

4.1 Designing Vapor Distribution Systems Questions with 100% Actual correct answers | verified | latest update | Graded A+ | Already Passed | Complete Solution











Whoops! We can’t load your doc right now. Try again or contact support.

Document information

Uploaded on
June 19, 2024
Number of pages
26
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

4.1 Designing Vapor Distribution
Systems

"Holiday" is a breakdown in the protective coating on a piece of equipment, can
result in localized corrosion, which then occurs at an accelerated rate. - correct
answer-




501 gallons or more: if the combined total water capacity of all cylinders is 501
gallons or more, then the cylinders must be placed 25Ft or further from a building. -
correct answer-




A leak test is performed after a leak is identified in a system, and it is performed ___
the pressure test and leak check. - correct answer-After




A lock up test measures the pressure in the lines downstream of the first stage
regulator to ensure that the regulator will shut off the flow of propane when the
appliances are not calling for gas. True or False. - correct answer-False




A single aboveground ASME tank up to 1,200 gallons water capacity can be placed
a minimum of 10 ft from buildings or property lines as long as there is no other
container installation of 125 gallons water capacity or more within 25ft. - correct
answer-




a single aboveground ASME tank up to 1,200 gallons water capacity: can be placed
a minimum of 10 ft from buildings or property lines that can be built upon, as long as
there is no other container installation of 125 gallons water capacity or more within
25 ft. - correct answer-

,Above ground ASME tanks must be positioned so that the relief valve discharge is
located at least 5 ft horizontally from any opening in the building below the level of
discharge. - correct answer-




Above ground ASME tanks must be positioned so that the relief valve discharge is
located at least 5 ft horizontally from any opening in the building below the level of
discharge. - correct answer-




Above ground tanks with less than ____ gallons water capacity may be placed next
to a building in must be at least ____ feet horizontally from any building opening that
is below the level discharge. - correct answer-125/5




Aboveground tanks with less than 125 gallons water capacity: may be placed next to
a building and must be at least 5 ft horizontally from any building opening that is
below the level of discharge. - correct answer-




Aboveground tanks with less than 125 gallons wc may be placed next to a building
and must be at least 5 feet horizontally from any building opening that is below the
level of discharge. - correct answer-




According to DOT requirements, which of the following containers cannot be
transported on public roadways to the customer site? - correct answer-A 1000 gallon
ASME tank containing 100 gallons of liquid propane.




According to NFPA 54 a pressure test applies pressure of not less than __ times the
proposed maximum working pressure of the interior piping, but in no case less than
__ psig. - correct answer-1 and 1/2

, 3




According to NFPA 58 requirements for above ground lines, you can use PE pipe,
tubing, and fittings in above ground line installations. True or false? - correct
answer-False




According to NFPA 58, if any underground tank isn't protected from damage due to
vehicle traffic, then how many inches below grade mass in underground tank beware
vehicle traffic is expected to cross the location of the tank? - correct answer-18
inches




According to the NFPA 58 requirements, which of the following is a requirement for
piping installation? - correct answer-Vapor distribution system piping can never be
used as a grounding electrode.




After the interior distribution system is installed, inspected for NFPA 54 code
requirements, and is ready to be placed into operation, the meter or regulator will
have to be connected to the interior system. This assessment will be conducted after
the connections are made between the exterior and interior portions of the system,
subsequent to the installation of the container, piping, and regulators. True or false? -
correct answer-False




All containers filled on site at the point of use must be positioned so that the filling
connection, the relief valve discharge and the fixed maximum liquid level gauge vent
discharge are situated at least 10 ft from: - correct answer-any source of ignition
such as window air conditioners or pool heaters.




An opening into direct-vent appliances

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
DoctorHkane Havard School
View profile
Follow You need to be logged in order to follow users or courses
Sold
735
Member since
4 year
Number of followers
168
Documents
22476
Last sold
20 hours ago

Explore my Stuvia collection for essential study aids: test banks, exams, summaries, and cases. With five years of expertise as an academic writer, I have honed my skills in crafting top-notch essays, exams, and research dissertations. My proficiency lies in producing well-structured and thoroughly researched content that meets academic standards. I am adept at handling various subjects and ensuring a seamless flow of ideas. Whether it's delivering compelling arguments in essays, creating challenging yet fair exam questions, or delving into in-depth research for dissertations, my experience equips me to excel in diverse academic writing tasks. I pride myself on meeting deadlines and maintaining the highest quality in every piece I produce. REACH ON iamnjokikelvin1@gmail

Read more Read less
4.6

387 reviews

5
309
4
29
3
21
2
10
1
18

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Frequently asked questions