Basic Dysrhythmia Review | 100% Correct | Verified | Latest 2024 Version
Basic Dysrhythmia Review | 100% Correct | Verified | Latest 2024 Version normal sinus rhythm (NSR) Criteria: (PR, QRS, QT, Rhythm: reg or irreg) 1 P-wave for Every QRS, REGULAR rhythm PR: 0.12-0.20 QRS: 0.06-0.10 BBB = > 0.12 QT: 0.36-0.44 BPM: 60-100 Sinus Bradycardia Criteria: (PR, QRS, QT, Rhythm: reg/irreg) PR: 0.12-0.20 QRS: 0.06-0.10 QT: 0.36-0.44 BPM: < 60 (Reg. rate) Tx: Atropine 0.5mg, Pace, Dopamine 2-10 mcg/kg/min, Epie 2-10 mcg/min Brainpower Read More Sinus Tachycardia Criteria: (PR, QRS, QT, Rhythm: reg/irreg) PR: 0.12-0.20 QRS: 0.06-0.10 QT: 0.36-0.44 BPM: 100-150 (Reg. rate, P wave may merge with T-wave) Cause: fear, anxiety, hypoxia, sepsis, hypovolemia, infection Sinus Arrhythmia Criteria: (PR, QRS, QT, Rhythm: reg/irreg) PR: 0.12-0.20 QRS: 0.06-0.10 QT: 0.36-0.44 BPM: HR increase w/ inspiration, HR decrease w/expiration P-P interval lengthen and shorten with respirations Irreg Rhythm NO TX Sinus Pause Criteria: (PR, QRS, QT, Rhythm) PR: 0.12-0.20 QRS: 0.06-0.10 QT: 0.36-0.44 Irregular rhythm Short Pause: no TX; Long/Freq. Pause & symptomatic = TX like Sinus Brady Premature Atrial Contraction (PAC) Heart Rate: Depends on underlying rhythm Regularity: Interrupts the regularity of underlying rhythm P-Wave: can be flattened, notched, or unusual. May be hidden within the T wave PRI: measures between .12-.20 seconds and can be prolonged; can be different from other complexes QRS: <.12 seconds TX: none, check Lytes, precursor for A-Fib/Flutter Atrial Fibrillation (A-Fib) (PR, QRS, QT, RHYTHM, TX) PR: Can't Measure NO P WAVE QRS: 0.06-0.10 QT: May/May Not be Measurable Rhythm: IRREGULARLY IRREGULAR Rate: Atrial >400 BPM Tx: Diltiazem (Cardizem), Amiodarone, Beta Blocker (Lopressor), Digoxin, Anti-Coag (Heparin), Cardiovert Atrial Flutter (PR, QRS, QT, RHYTHM, TX) PR: Can't Measure NO P WAVE QRS: 0.06-0.10 QT: Can't Measure Rhythm: Ventricular Rate = Reg. Atrial = Irreg Atrial Rate 250-400 Ventricular: count QRS "Saw Tooth/Flutter Waves" Tx: Same as A-Fib paroxysmal atrial tachycardia (PAT) (PR, QRS, QT, RHYTHM, TX) an episode that begins and ends abruptly during which there are very rapid and regular heartbeats that originate in the atrium PR: 0.12-0.20 QRS: 0.06-0.10 QT: 0.36-0.44 Atrial Rate: 150-250 Reg
Written for
- Institution
- Registered Nurse Basic Dysrhythmia
- Module
- Registered Nurse Basic Dysrhythmia
Document information
- Uploaded on
- May 14, 2024
- Number of pages
- 10
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
basic dysrhythmia review 100 correct verifie
Also available in package deal