100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

EPA 608 Certification Exam Questions and answers

Rating
-
Sold
-
Pages
7
Grade
A
Uploaded on
07-05-2024
Written in
2023/2024

EPA 608 Certification Exam Questions and answers Ozone depletion is caused by _ in HCFC refrigerants - ANSWERS Chlorine CFCs and HCFCs _ making them capable of reaching the stratospheric ozone - ANSWERS do not dissolve in water or easily break down in the atmosphere How many ozone molecules are destroyed by one chlorine atom - ANSWERS 100,000 ozone molecules The stratospheric ozone layer protects us from _ - ANSWERS ultraviolet radiation from the sun Which health effect increases from loss of the stratospheric ozone layer - ANSWERS Cases of cataracts and skin cancer Which of the following proves that HCFCs are in the stratosphere - ANSWERS HCFCs found in air samples from the stratosphere What makes HFC refrigerants damaging to the environment - ANSWERS They have very high global warming potentials _ makes HFO refrigerants less flammable than HC refrigerants - ANSWERS Fluorine Which refrigerant contains chlorine - ANSWERS R12 HFO refrigerants are miscible in _ lubricants. - ANSWERS POE lubricants An example of an HCFC refrigerant is - ANSWERS R-123 What is being done in the U.S. to stop damage to the stratospheric ozone layer - ANSWERS Eliminating the use of CFCs and HCFCs refrigerants EPA regulations require appliances to have _ - ANSWERS a service aperture or process stub The release of any CFC, HCFC, or HFC refrigerant during _ is illegal. - ANSWERS theft of equipment _ is the only EPA SNAP approved "drop-in" replacement for R-22. - ANSWERS There are no direct drop in refrigerant substitutes Ester-based oils like POE can be mixed with _ - ANSWERS no other oils What provides the cooling in a vapor compression refrigeration system - ANSWERS the vaporization of the liquid refrigerant An oil sample might be taken when _ - ANSWERS moisture and/or acid problems are suspected oil sludge formation or oil waxing is suspected residual acidic oil from a burn-out is suspected of contaminating the replacement oil _ returns refrigerant to new product specifications and requires chemical analysis to verify the purity to AHRI-700 standards - ANSWERS Reclaiming the EPA considers _ the most effective for locating the general area of a small leak - ANSWERS electronic or ultrasonic tester Low ambient temperatures _ recovery time. - ANSWERS increase A system is considered dehydrated when - ANSWERS a micron-gauge shows you have reached and held a vacuum of 500 microns or less with the vacuum pump isolated from the system If corrosion is discovered in the body of a relief valve, the valve must be _ - ANSWERS replaced The fill level of a recovery cylinder can be determined by _ - ANSWERS Mechnical float, electronic shut off devices, or the weight of a cylinder Before recharging any flammable hydrocarbon or HFO refrigerant, always _ - ANSWERS Electronically ground the recovery machine and recovery tank and verify the system is grounded and install a fresh filter drier successfully complete a standing pressure leak check at the maximum system pressure and then evacuate to at least 500 microns A small appliance is defined as a system that is - ANSWERS manufactured, fully charged, and hermetically sealed in a factory with a charge of 5 pounds or less _ is an approved refrigerant for new household refrigerators, freezers, and combination refrigeration/freezers - ANSWERS R-600a the hydrocarbon refrigerant approved for retrofit into existing household refrigerators is - ANSWERS none, hydrocarbons are not approved for any retrofit applications Recovery devices for use with small appliances must be capable of - ANSWERS recovering 90% of the refrigerant when the compressor is operating Recovery equipment is certified by - ANSWERS An EPA approved laboratory When recovering refrigerant from small appliances you must recover - ANSWERS at least 80% of the refrigerant with an inoperative compressor and 90% of the refrigerant with an operative compressor The sale of reclaimed CFC, HCFC, HFC, and HFO refrigerants is _ - ANSWERS restricted to technicians who are EPA certified in refrigerant recovery a process stub is a_ - ANSWERS straight piece of tubing that is entered using a piercing access valve Small appliances requires a_ or Universal certification - ANSWERS Type 1 If a recovery cylinder is suspected to be contaminated, measure the _ - ANSWERS pressure of the refrigerant in the cylinder You must know the _ before beginning a refrigerant recovery. - ANSWERS type of refrigerant that is in the system when installing an access fitting _ - ANSWERS the fitting should be verified as leak free before beginning any recovery to avoid drawing air into the recovery tank A passive system-dependent recovery device for small appliances: - ANSWERS uses a non pressurized container when recovering refrigerant using a passive recovery system and the system has an inoperative compressor it is - ANSWERS helpful to heat and strike the compressor with a rubber mallet to release any refrigerant trapped in and under the compressor oil what requires accessing both the high and low side of the system for refrigerant recovery when using a passive recovery process - ANSWERS when the compressor does not run What is the pressure of a storage cylinder of R-134a that is stored in a room where the temperature is 100 F - ANSWERS 124 psig Recovery of refrigerant cannot begin if the initial pressure of the system is _ - ANSWERS 0 psig What maintenance practice should be performed on a regular basis - ANSWERS Change the vacuum pump oil, and check the recovery equipment and manifold hose set for leaks Which refrigerants can be mixed in a system - ANSWERS Refrigerants cannot be mixed

Show more Read less
Institution
EPA 608 Certification
Module
EPA 608 Certification









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
EPA 608 Certification
Module
EPA 608 Certification

Document information

Uploaded on
May 7, 2024
Number of pages
7
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

£8.76
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached

Get to know the seller
Seller avatar
snownitch

Get to know the seller

Seller avatar
snownitch teach me 2
Follow You need to be logged in order to follow users or courses
Sold
0
Member since
1 year
Number of followers
0
Documents
32
Last sold
-

0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Frequently asked questions