Asbestos Test 1 Exam Questions With 100% Correct Answers ASB exposure is effected by exposure, accessibility, ________, and _________ - answerwater exposure and vibration What is the expression measurement for fibers per cubic centimeter? - answerf/cc Modifications of withdrawls to bids are effective - answerwhen filed before the opening of bids and in writing Friable asbestos material releases fibers when - answersanded, crushed, drilled or cut A type of filter in a cassette is - answera polycarbonate and cellulose ester filter NESHAPs stands for - answerNational Emission Standards for Hazardous Air Pollutants The decontamination unit should contain which type of sheeting - answer6 mil opaque black or white plastic If a contractor does not have the certification required under B&P code 7058.5, he is subject to the revocation of contractors license and - answera mandatory civil penalty of not less than ($1000) and not more than ($3000) What would be a time and cost effective method to abate a project? - answerRemove ACM in coordinance with renovation projects For which of the following is encapsulation a proper procedure? - answerAcoustical plaster in good condition Any person who may be exposed to an 8 hr. time weighted concentration of airborne asbestos fibers shall not exceed how many fibers and to which length per cubic centimeters of air? - answerShall not exceed 2 fibers, longer than 5 micrometers What is the maximum short term concentraction to which employees can be exposed? - answerIt shall not exceed 10 fibers longer than 5 micrometers When removing asbestos, it is always make sure that - answerthe asbestos has been wetted What three microscopic methods are currently being used to analyze asbestos? - answerPhase Contrast Microscopy (PCM), Scanning Electronic Microscopy (SEM), Transmission Electron Microscopy (TEM) What method is most avaliable, familiar and frequently used of the microscopic procedures? - answerPCM (Phase Contrast Microscopy) Which method gives the more complete information on airborne asbestos? - answerTEM (Transmission Electron Microscopy) Regardless of the microscopic method for measuring asbestos, what is the first important step in the process? - answerIdentifying a homogeneous worksite If a contractor who is required to be certified under B&P code 7058.5 and does not have a cert, they shall pay a mandatory fine of - answernot less than 1000 and not more than 3000 if conducting an air sample using TEM, you collect 6 samples from inside your worksite, you draw 2000 liters of air through each filter at 5 liters per minute and include one laboratory blank and one field blank, you have proceeded _____ according to the EPA. - answerincorrectly, the volume being drawn through each filter per minute is too low. (Draw at least 3000 liters of air through each filter at a rate of 2 to 12 liters per minute. This will take 3000 liters/12 liters per minute = 4 hours and 10 minutes) Emergency telephone numbers should be posted in the - answerclean change room and equipment (dirty) room Two thorough cleanings are necessary in cleaning up. The contractor must wait - answer24 hours between cleanings PCM cannot detect fibers below what level? - answer5 micrometers At what level above the ground should samples selected outside the building be taken? - answerClose to ground level (about 2 meters high) How long is airlock, according to the EPA? - answerThree feet Part of the function of the encapsulant is _____ and therefore should not be applied to thick material - answerpeneteration The most likely cause if ACM has delaminated or seperated into layers exposing asbestos fibers is - answerwater damage The program manager should keep open communication and notify - answerthe building occupants when inspeciting a building If the owner requests you add another section of the building to the abatement, can you accept this orally? - answerNo, instructions or agreements are not binding

Show more Read less
Institution
Asbestos
Module
Asbestos









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Asbestos
Module
Asbestos

Document information

Uploaded on
March 20, 2024
Number of pages
8
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

Asbestos Test 1 Exam Questions With 100%
Correct Answers

ASB exposure is effected by exposure, accessibility, ________, and _________ -
answer✔✔water exposure and vibration

What is the expression measurement for fibers per cubic centimeter? - answer✔✔f/cc

Modifications of withdrawls to bids are effective - answer✔✔when filed before the opening of
bids and in writing

Friable asbestos material releases fibers when - answer✔✔sanded, crushed, drilled or cut

A type of filter in a cassette is - answer✔✔a polycarbonate and cellulose ester filter

NESHAPs stands for - answer✔✔National Emission Standards for Hazardous Air Pollutants

The decontamination unit should contain which type of sheeting - answer✔✔6 mil opaque black
or white plastic
If a contractor does not have the certification required under B&P code 7058.5, he is subject to
the revocation of contractors license and - answer✔✔a mandatory civil penalty of not less than
($1000) and not more than ($3000)

What would be a time and cost effective method to abate a project? - answer✔✔Remove ACM
in coordinance with renovation projects

For which of the following is encapsulation a proper procedure? - answer✔✔Acoustical plaster
in good condition
Any person who may be exposed to an 8 hr. time weighted concentration of airborne asbestos
fibers shall not exceed how many fibers and to which length per cubic centimeters of air? -
answer✔✔Shall not exceed 2 fibers, longer than 5 micrometers
What is the maximum short term concentraction to which employees can be exposed? -
answer✔✔It shall not exceed 10 fibers longer than 5 micrometers

When removing asbestos, it is always make sure that - answer✔✔the asbestos has been wetted
What three microscopic methods are currently being used to analyze asbestos? -
answer✔✔Phase Contrast Microscopy (PCM), Scanning Electronic Microscopy (SEM),
Transmission Electron Microscopy (TEM)

, What method is most avaliable, familiar and frequently used of the microscopic procedures? -
answer✔✔PCM (Phase Contrast Microscopy)

Which method gives the more complete information on airborne asbestos? - answer✔✔TEM
(Transmission Electron Microscopy)
Regardless of the microscopic method for measuring asbestos, what is the first important step in
the process? - answer✔✔Identifying a homogeneous worksite
If a contractor who is required to be certified under B&P code 7058.5 and does not have a cert,
they shall pay a mandatory fine of - answer✔✔not less than 1000 and not more than 3000
if conducting an air sample using TEM, you collect 6 samples from inside your worksite, you
draw 2000 liters of air through each filter at 5 liters per minute and include one laboratory blank
and one field blank, you have proceeded _____ according to the EPA. - answer✔✔incorrectly,
the volume being drawn through each filter per minute is too low.


(Draw at least 3000 liters of air through each filter at a rate of 2 to 12 liters per minute. This will
take 3000 liters/12 liters per minute = 4 hours and 10 minutes)

Emergency telephone numbers should be posted in the - answer✔✔clean change room and
equipment (dirty) room

Two thorough cleanings are necessary in cleaning up. The contractor must wait - answer✔✔24
hours between cleanings

PCM cannot detect fibers below what level? - answer✔✔5 micrometers
At what level above the ground should samples selected outside the building be taken? -
answer✔✔Close to ground level (about 2 meters high)

How long is airlock, according to the EPA? - answer✔✔Three feet
Part of the function of the encapsulant is _____ and therefore should not be applied to thick
material - answer✔✔peneteration
The most likely cause if ACM has delaminated or seperated into layers exposing asbestos fibers
is - answer✔✔water damage

The program manager should keep open communication and notify - answer✔✔the building
occupants when inspeciting a building
If the owner requests you add another section of the building to the abatement, can you accept
this orally? - answer✔✔No, instructions or agreements are not binding
£8.85
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached


Also available in package deal

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
TheStar Florida State University
Follow You need to be logged in order to follow users or courses
Sold
590
Member since
1 year
Number of followers
178
Documents
23589
Last sold
2 days ago
Stuvia Prodigy

Tested, Verified and Updated Study Materials with 100% Guaranteed Success.

3.8

118 reviews

5
56
4
21
3
20
2
4
1
17

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Frequently asked questions