100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

NCLE Test Questions & Answers Solved 100%

Rating
-
Sold
-
Pages
26
Grade
A+
Uploaded on
30-10-2023
Written in
2023/2024

Assessment of the quality of the peripheral curves (blends of a rigid contact lens) is achieved by the use of the- a. profile analyzer b. shadow graph c. keratometer d. burton light - Answer a. profile analyzer Contact lens power should be specified in- a. back vertex power b. sphero-cylinder power c. power in situ d. posterier apical radius - Answer a. back vertex power The slit-lamp illumination that gives an overall view of the cornea but limits detail is- a. sclerotic scatter b. diffuse c. specular reflection d. oscilatory - Answer b. diffuse When a keratometric miers reflected off a soft contact lens are only clear when the wearer blinks, the lens fit is too- a. small b. large c. steep d. flat - Answer c. steep Transient keratometric mier distortion is usually due to- a. pre-ocular tear film abnormalities b. prolonged rigid lens wear c. prolonged soft lens wear d. irregular corneal astigmatism - Answer a. pre-ocular tear film abnormalities Epithelial edema which manifests itself clinically as central corneal haze, is verified by the slit lamp using sclerotic scatter illumination. What specific technique does the examiner use to see this condition? a. the naked eye and an angle between the slit lamp beam and the eye of 90˚ b. the blue cobalt filter of the slit lamp and an angle of about 45˚ c. the green filter of the slit lamp with high magnification d. high magnification and an angle between the beam and scope of 180˚ - Answer a. the naked eye and an angle between the slit lamp beam and the eye of 90˚ With a rigid contact lens in place a flourescein pattern shows a narrow bend horizontally wih a concentration of flourescein inferiorly and superiorly under the lens. Which one of the following type of astigmatism is represented by this pattern? a. lenticular astigmatism b. residual astigmatism c. against the rule astigmatism d. with the rule astigmatism - Answer d. with the rule astigmatism Refractive Rx -3.00 -1.00 x 170 K's 42.00 @ 170/43.00 @ 80 Given the above Rx and K's he following diagnostic toric soft lens was used: B.C. 8.8 Power -3.00 -1.00 x 180 During dianostic evalutation, the above lens rotated 10 clockwise. The lens ordered should have an axis of: a. 10 b. 180 c. 170 d. 160 - Answer b. 180 Given the same circumstances from the above question, once the correctly ordered lens has been dispensed, the rotational marks should settle at _______. a. 6 o clock b. 10 clockwise rotation c. 10 counter clockwise rotation d. none of the above - Answer b. 10 clockwise rotation An instrument that allows simultaneous verification of lens diameter, optic zone width, and peripheral curve width is: a. measuring magnifier b. ophthalmometer c. profile analyzer d. radiuscope - Answer a. measuring magnifier (the book says d. radiuscope) The instrument used for magnification of the edge of a rigid CL is a _______. a. radiuscope b. shadowgraph c. profile analysis d. keratometer - Answer b. shadowgraph Mary is wearing in her right eye RGP lens with a base curve of 43.50 and a power of +2.75. The doctor refracts -0.75 sphere over this lens. If you wish to order her a new lens with a curve of 43.00, what will the new power be? a. +1.50 b. +2.00 c. +2.50 d. +3.00 - Answer c. +250 Which of the following could be considered in the fitting of a keratoconus patient 1. aspheric 2. McGuire 3. Soper 4. tangent streak a. 1 & 2 b. 2 & 3 c. 3 & 4 d. 1, 2 and 3 - Answer d. 1, 2 and 3 Two designs helpful in orienting high riding myopic lenses are: 1. flattening the B.C. relationship 2. myo-flang 3. hyper-flang 4. prism ballast a. 1 & 2 b. 1 & 3 c. 2 & 3 d. 3 & 4 - Answer d. 3 & 4 Age/related signs of presbyopia include: 1. tear film abnormalities 2. reduce lid elasticity 3. lens opacities 4. pupil constriction a. 1 only b. 1 & 3 c. 2 & 4 d. all of the above - Answer d. all of the above A good example of a bifocal contact lens which may rotate without vision imparement is: a. aspheric b. executive c. fused crescent d. tangent streak - Answer d. tangent streak Keratoconus and penetrating keratoplasty fittings are best accomplished by which of the following methods? a. nomogram b. Ks and Rx c. diagnostic fitting d. molded impression - Answer c. diagnostic fitting Given the following information: K's 45.00/44.00 @ 90 Rx -3.00 + 1.00 x 180 Which of the following set of lens specifications would most simulate an intrapalpebral RGP fitting? B.C Rx Dia. a. 44.50 -2.50 8.5 b. 43.50 -1.50 8.5 c. 43.50 -1.50 9.5 d. 44.50 -2.50 9.5 - Answer B.C Rx Dia. a. 44.50 -2.50 8.5 (NUMBER 22) Given the following information: K's 45.00 @ 180/42.00 @ 90 Rx -2.00 -4.25 x 90 Which of the following RGP lens designs would best correct this wearers vision? a. 45.00 -2.00 b. 42.00 -2.00 -4.25 x 90 prism ballasted c. 42.00 -2.00 d. 42.00/45.00 -2.00 - Answer d. 42.00/45.00 -2.00 A _________ lens is a translating bifocal: a. concentric b. aspheric c. deffractive d. segmented - Answer d. segmented Given the following information: K's 42.50@180/42.50@90 Rx -3.00-1.00@90 Which of the following set of RGP lens specifications will best correct this wearers vision? a. 42.50/43.50 -3.00-1.00x90 b. 42.50 -3.00-1.00x90 prism ballasted c. 42.50 -3.00 d. 43.00 -3.50 - Answer b. 42.50 -3.00-1.00x90 prism ballasted Given the following information: K's 42.00@180/45.00@90 Rx -3.00-2.25x180 Which of the following set of RGP lens specifications will best correct this wearers vision? a. 42.00/45.00 -3.00-2.25 b. 42.00 -3.00-2.75 x 177 prism ballasted c. 42.00 -3.00 d. 45.00 -3.00 - Answer a. 42.00/45.00 -3.00-2.25

Show more Read less
Institution
NCLE
Module
NCLE










Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
NCLE
Module
NCLE

Document information

Uploaded on
October 30, 2023
Number of pages
26
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

£9.19
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached


Also available in package deal

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Exampool NURSING
Follow You need to be logged in order to follow users or courses
Sold
219
Member since
2 year
Number of followers
147
Documents
3591
Last sold
1 month ago
Power-horse Library

HELLO Dear ones On this Account you will find all Study related Materials ,EXAMS, STUDY GUIDES, CASES,NOTEBOOKS and many more. well come as we study for Excellency.

3.9

32 reviews

5
16
4
2
3
10
2
2
1
2

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Frequently asked questions