100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.6 TrustPilot
logo-home
Exam (elaborations)

EPA 608 Type I from practice test-solved

Rating
-
Sold
-
Pages
2
Grade
A+
Uploaded on
30-06-2023
Written in
2022/2023

Technicians who perform sealed system service on small appliances must have; - Answer- Type I or universal certification A small appliance is defined by EPA as; - Answer- Appliances manufactured, charged, and hermetically sealed in a factory with 5 lbs or less of refrigerant Type I Certification is required for; - Answer- Persons handling refrigerant during maintenance, service, or repair of small appliances. If regulations change after the technician becomes certified; - Answer- The technician is responsible for complying with any future changes in the regulations. Recovery equipment manufactured after November 15, 1993 must be; - Answer- Certified by an EPA approved testing laboratory. Which of the following is true of small appliances refrigerant leaks; - Answer- EPA does not require repair, but leaks should be repaired whenever possible. Recovery equipment manufactured after November 15, 1993 must be capable of recovering; - Answer- 90% of the refrigerant or achieving 5 inches of vacuum. Recovering multiple types of refrigerants in the same cylinder; - Answer- Will make the reclaimed refrigerants non reclaimable and a charge for disposal may be levied. Self-contained or active recovery equipment; - Answer- Has its own means of recovery. System-dependant or passive recovery equipment; - Answer- Captures refrigerant into a non-pressurized container with assistance of the appliance compressor. What is defined as a non-condensible? - Answer- Air When using a system-dependent recovery system on an appliance that has an operating compressor, the technician should; - Answer- Run the compressor and recover from the high side of the system. When using a system-dependent recovery system on an appliance that has a non-operating compressor, the technician should; - Answer- Place access fittings on both the low and high side of the system. System-dependant devices may only be used on appliances containing; - Answer- 15 lbs of refrigerant or less. Small appliances are equipped with a straight piece of tubing (process stub) used to; - Answer- Install a piercing type access valve fitting. If a strong odor is detected while performing the recovery process, - Answer- A compressor burnout has likely occurred. After the refrigerant has been recovered, which of the following can be used to flush the system? - Answer- Nitrogen. When filling a charging cylinder with a regulated refrigerant; - Answer- The refrigerant vapor that is vented off the top of the cylinder must be recovered. If after installing a fitting for the purpose of recovering the appliances refrigerant, you find that the system pressure is 0 psig; - Answer- Recovery is not required. Applying heat with a heat gun to the compressor; - Answer- Can help vaporize any trapped liquid refrigerant during recovery. Refrigerators in the 1950's and earlier may have used what refrigerants (recovery is not required)? - Answer- Methyl Formate, Methyl Chloride, or Sulfur Dioxide. Small appliances in recreational vehicles may use refrigerants such as Ammonia, Hydrogen, or water, and therefore; - Answer- The refrigerant should not be recovered. Recovery equipment manufactured before November 15, 1993 must be capable of recovering. - Answer- 80% of the refrigerant or achieving 4 inches of vacuum. When pressurizing a system with nitrogen you should; - Answer- Charge through a pressure regulator and place a relief valve in the downstream line from the pressure

Show more Read less
Institution
EPA 608
Module
EPA 608








Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
EPA 608
Module
EPA 608

Document information

Uploaded on
June 30, 2023
Number of pages
2
Written in
2022/2023
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

£6.91
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached


Also available in package deal

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
millyphilip West Virginia University
Follow You need to be logged in order to follow users or courses
Sold
2827
Member since
3 year
Number of followers
1958
Documents
41711
Last sold
4 days ago
white orchid store

EXCELLENCY IN ACCADEMIC MATERIALS ie exams, study guides, testbanks ,case, case study etc

3.7

536 reviews

5
234
4
85
3
103
2
31
1
83

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Frequently asked questions