100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

Army Electrical Explosives Safety (Ammo-28) Exam with 100% Correct Answers 2023

Rating
-
Sold
1
Pages
6
Grade
A+
Uploaded on
06-02-2023
Written in
2022/2023

Army Electrical Explosives Safety (Ammo-28) Exam with 100% Correct Answers 2023 Which two publications provide detailed information on lightning protection systems? - Correct answer-DA PAM 385-64 NFPA 780 Which statements about lightning protection are true?Select all that apply. - Correct answer-Lightning can detonate munitions and explosives. Lightning seeks the path of least resistance to ground. Lightning cannot be stopped or prevented. Which statement is true about a mast LPS? - Correct answer-Each mast must have two paths to ground. A 30-foot tall building is protected by a catenary system. How far from the building should the masts be placed? - Correct answer-at least 6 feet Which LPS uses air terminals and conductors mounted directly to the structure? - Correct answer-Integral Why does the wooden mast have an air terminal on top and two down conductors running its entire length? - Correct answer-The wooden mast is not electrically conductive Which of the following is NOT a requirement for air terminals? - Correct answer-Air Terminals must be at least 6 feet tall. During the inspection, John's team logged a discrepancy for this air terminal. Why? - Correct answer-The air terminal is not attached to a conductor. How many down conductors are required for a building with a perimeter length of 325 feet? - Correct answer-4 While conducting an LPS inspection, you see mast down conductors routed as shown in the image below. Do you write it up as a discrepancy? Why or why not? - Correct answer-Yes, because mast down conductors should be 180 degrees apart. A steel beam, connected to the main LPS at its upper and lower extremities, is used as a down conductor. At what intervals should it be connected to the grounding system? - Correct answer-60 feet or less Which statement about grounding systems is true? - Correct answer-The resistance should be 25 ohms or less. Which of the following statements regarding bonding are true? Select all that apply. - Correct answer-Bonding reduces the threat of sideflash by providing a low impedance path to ground. Bonding is a way of connecting LPS conductors to grounded metal objects. When should a grounded metal object be considered for bonding? - Correct answerWhen it's within 6 feet of a conductor Which bonding method is the most permanent and secure? - Correct answerExothermic weld Which factors are used to calculate bonding distance?Select all that apply. - Correct answer-Height of proposed bond Flashover medium Number of down conductors While conducting the inspection, John's team noticed a new metal light pole installed 3 feet from the down conductor at the corner of this building. They logged a discrepancy. Why? - Correct answer-Because grounded metal objects within 6 feet of LPS conductors should be bonded to it Which types of information does an LPS record provide? Select all that apply. - Correct answer-Test locations Test item descriptions or listing Type of test Responsibilities for conducting and administering the test plan Which section of DA PAM 385-64 provides LPS visual inspection guidance? - Correct answer-Appendix D How often is a visual inspection required on an LPS? - Correct answer-Every 12 months While conducting the LPS inspection, the team saw these surveillance cameras. Does this building comply with LPS standards? - Correct answer-No, because the surveillance cameras are outside the zone of protection. How long must LPS test results be kept on file? - Correct answer-6 inspection cycles How often is a conductive floor electrical test required in an ESD-sensitive operating facility? - Correct answer-Every 6 months For best accuracy, how many individual resistance tests are recommended for a conductive floor? Refer to DA PAM 385-64, Section C-3 as required. - Correct answer-Ten test: Five electrode-to-electrode tests and five electrode-to-ground tests This conductive floor was tested at five locations. The average resistance of the electrode-to-electrode test was 55,871 ohms. Does this test pass? Refer to DA PAM 385-64, Section C-3. - Correct answer-Yes, because an average resistance of 55,871 ohms is within standards How often is a 3-point fall-of-potential earth resistance test required on an LPS? - Correct answer-Every 24 months When conducting a 3-point fall-of-potential earth resistance test on an integral LPS, how far from the ground rod should you place the C2 and P2 test probes? Refer to DA PAM 385-64, Table B-1 as required. Select one response for the C2 probe distance and one response for the P2 probe distance. - Correct answer-C2 probe at 131 feet P2 probe at 82 feet What is the maximum allowable resistance reading for a 3-point fall-of-potential earth resistance test? - Correct answer-25 ohms or less How often is a bonding resistance test required on an LPS? - Correct answer-Every 24 months What is the maximum allowable reading for a bonding resistance test on an LPS conductor? - Correct answer-1 ohm or less When conducting a bonding resistance test on an integral LPS with 10 air terminals and two down conductors, how many individual resistance tests are required, at a minimum? - Correct answer-20 While conducting a bonding resistance test on the integral LPS below, you placed test leads on ground rod S and air terminal N. Which three bonds listed below are NOT being tested? - Correct answer-B H P What information should be in a destructive weather plan? Select all that apply. - Correct answer-Which operations to shut down Who is responsible for shutting down each operation Steps for shutting down each operation Instructions for evacuating personnel Instructions for restarting each operation Spheric - Correct answer-Detects lightning strike Alerts when lightning is nearby Pre-strike - Correct answer-Measure the strength of atmospheric electric fields Alerts when lightning strikes are imminent What is the primary danger in a hazardous classified location? - Correct answerExplosive atmosphere Which division describes a hazardous classified location with greatest probability of ignition or explosion? - Correct answer-Division 1 Which two agencies tests and certify explosion-proof electrical equipment? - Correct answer-Army Ordnance Safety and Security Activity (AOSSA) Factory Mutual (FM) Underwriter's Laboratory (UL) Which device does NOT emit electromagnetic radiation? - Correct answer-Calculator Which three are hazards posed by electromagnetic radiation? - Correct answerGeneration of extreme heat in the human body ignition of fuel and other combustibles Activation or disabling of electrically initiated devices (EIDs)

Show more Read less
Institution
Army Electrical Explosives Safety
Module
Army Electrical Explosives Safety









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
Army Electrical Explosives Safety
Module
Army Electrical Explosives Safety

Document information

Uploaded on
February 6, 2023
Number of pages
6
Written in
2022/2023
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

£8.57
Get access to the full document:

100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached


Also available in package deal

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
professoraxel Havard School
Follow You need to be logged in order to follow users or courses
Sold
2335
Member since
3 year
Number of followers
1567
Documents
19210
Last sold
1 day ago
THE EASIEST WAY TO STUDY NURSING EXAMS,STUDY GUIDES,TESTBANKS AND QUALITY EXAMS

Better grades start here! Find Study Notes, Exam answer packs, Assignment guided solutions and more. Study faster & better. Always leave a review after purchasing any document so as to make sure our customers are 100% satisfied.....All the Best!!!!!!

3.8

441 reviews

5
203
4
79
3
85
2
24
1
50

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Frequently asked questions