100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached 4.2 TrustPilot
logo-home
Exam (elaborations)

Elevator Mechanic Exam (well explained)

Rating
-
Sold
-
Pages
28
Grade
A+
Uploaded on
29-12-2022
Written in
2022/2023

Elevator Mechanic Exam (well explained) ASME - answer American Society of Mechanical Engineers DOSH - answer Division of Occupational Safety and Health LADBS - answer Los Angeles Department of Building and Safety Alteration made to conveyance shall comply with ASME A17.1-204 Section - answer 8.7 The seismic section of ASME A17.1-2004 and alterations made to conveyances must also comply with this section - answer 8.4 What must be submitted to the applicable Division Elevator office prior to beginning construction or alterations on a conveyance Title 8 Sec 3000 - answer Letter of Intent When shall Category One Tests on conveyances be completed Title 8 Sec 3141.6 - answer Once every 12 months What shall be provided on all conveyances regardless of the existence of an emergency stop switch ASME A17.1-2004 2.27.1.2 - answer Audible signaling device When are Hoistway door unlocking devices on all conveyances required Title 8 Sec 3141.7 ASME A17.1-2004 2.12.6 - answer Prohibited What section should Group IV platform lifts and stairway chairlifts shall comply with - answer ASME A18.1-2003 When setbacks or projections exceed this number of inches, occur in the enclosure wall, the top of the setback or projection shall be beveled at an angle not less than 75 degrees with the horizontal ASME A17.1-2004 2.1.6 - answer 4 inches At what height shall the hoistway enclosure of a Group IV elevator be Unperforated ASME A17.1-2004 2.1.1.2.2 - answer 79 inches For elevators installed after June 5, 1947, there shall be installed in the pit of each elevator where the pit extends below the sill of the pit access door a fixed vertical ladder. How many inches below the sill? ASME A17.1-2004 2.2.4.2 - answer 35 inches On a Group IV elevator, what is the minimum pit lighting illumination that should be provided at the pit floor ASME A17.1-2004 2.2.5.1 - answer 10 fc (foot candles) For Group IV elevators that are not fully enclosed, how high of protection should be provided on the hoistway sides that are located 59 inches or less from elevator equipment in areas accessible to other than elevator personnel ASME A17.1-2004 2.2.1.3 - answer 94.5 inches Permanent means shall be provided to prevent the accumulation of what?, in the elevator pit ASME A17.1-2004 2.2.2.3 - answer Water In place of a sump pump, what else shall be provided on elevators equipped with Firefighters' Emergency Operation ASME A17.1-2004 2.2.2.5 - answer Drain On a Group IV elevator, how far shall a pit ladder extend no less than how many inches above the sill of the access door ASME A17.1-2004 2.2.4.2 - answer 48 inches Where pit mounted counterweight buffers are used, a counterweight guard is not required when the bottom of the counterweight resting on its compressed buffer is how many inches or more above the pit floor ASME A17.1-2004 2.3.2.2 5.10.1.3.2 - answer 84 inches When an elevator rests on its fully compressed buffers or bumpers, there shall be a vertical clearance of not less than how many inches between the pit floor and the lowest structural or mechanical part, equipment, or device installed beneath the car platform ASME A17.1-2004

Show more Read less










Whoops! We can’t load your doc right now. Try again or contact support.

Document information

Uploaded on
December 29, 2022
Number of pages
28
Written in
2022/2023
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

Content preview

Elevator Mechanic Exam (well explained)



ASME - answer American Society of Mechanical Engineers

DOSH - answer Division of Occupational Safety and Health

LADBS - answer Los Angeles Department of Building and Safety

Alteration made to conveyance shall comply with ASME A17.1-204 Section - answer 8.7

The seismic section of ASME A17.1-2004 and alterations made to conveyances must also comply
with this section - answer 8.4

What must be submitted to the applicable Division Elevator office prior to beginning construction
or alterations on a conveyance

Title 8 Sec 3000 - answer Letter of Intent

When shall Category One Tests on conveyances be completed

Title 8 Sec 3141.6 - answer Once every 12 months

What shall be provided on all conveyances regardless of the existence of an emergency stop
switch

ASME A17.1-2004

2.27.1.2 - answer Audible signaling device

When are Hoistway door unlocking devices on all conveyances required

Title 8 Sec 3141.7

ASME A17.1-2004

2.12.6 - answer Prohibited

What section should Group IV platform lifts and stairway chairlifts shall comply with - answer
ASME A18.1-2003

When setbacks or projections exceed this number of inches, occur in the enclosure wall, the top
of the setback or projection shall be beveled at an angle not less than 75 degrees with the
horizontal

ASME A17.1-2004

2.1.6 - answer 4 inches

At what height shall the hoistway enclosure of a Group IV elevator be Unperforated

ASME A17.1-2004

2.1.1.2.2 - answer 79 inches

,For elevators installed after June 5, 1947, there shall be installed in the pit of each elevator where
the pit extends below the sill of the pit access door a fixed vertical ladder. How many inches below
the sill?

ASME A17.1-2004

2.2.4.2 - answer 35 inches

On a Group IV elevator, what is the minimum pit lighting illumination that should be provided at
the pit floor

ASME A17.1-2004

2.2.5.1 - answer 10 fc (foot candles)

For Group IV elevators that are not fully enclosed, how high of protection should be provided on
the hoistway sides that are located 59 inches or less from elevator equipment in areas accessible
to other than elevator personnel

ASME A17.1-2004

2.2.1.3 - answer 94.5 inches

Permanent means shall be provided to prevent the accumulation of what?, in the elevator pit

ASME A17.1-2004

2.2.2.3 - answer Water

In place of a sump pump, what else shall be provided on elevators equipped with Firefighters'
Emergency Operation

ASME A17.1-2004

2.2.2.5 - answer Drain

On a Group IV elevator, how far shall a pit ladder extend no less than how many inches above the
sill of the access door

ASME A17.1-2004

2.2.4.2 - answer 48 inches

Where pit mounted counterweight buffers are used, a counterweight guard is not required when
the bottom of the counterweight resting on its compressed buffer is how many inches or more
above the pit floor

ASME A17.1-2004

2.3.2.2

5.10.1.3.2 - answer 84 inches

When an elevator rests on its fully compressed buffers or bumpers, there shall be a vertical
clearance of not less than how many inches between the pit floor and the lowest structural or

, mechanical part, equipment, or device installed beneath the car platform

ASME A17.1-2004

2.4.1 - answer 24 inches

The minimum bottom runby of an un-counterweighted Group IV elevators shall not be less than
how many inches where the rated speed exceeds 30 fpm

ASME A17.1-2004

2.4.3 - answer 6 inches

In no case shall the maximum bottom runby exceed how many inches for cars

ASME A17.1-2004

2.4.4 - answer 24 inches

In no case shall the maximum bottom runby exceed how many inches for counterweights - answer
35 inches

The illumination measured at the landing sills of a Group IV elevator shall not be less than how
many foot candles

ASME A17.1-2004

2.11.10.2 - answer 10 fc

What minimum size traveling cable conductor is used for elevator wiring other than those
supplying light and control equipment circuits.

14 gauge for lighting and control equipment - answer 20 gauge

Phase I fire recall and a minimum of one floor operation of phase II fire service shall be tested how
often to ensure the system is in proper working order - answer Monthly

Which of the following elevators require 5 yr load test to be performed: Group II, Group III, Group
IV

Title 8 Sec 3071 - answer All of the above

The tripping speed of an overspeed valve on a hydraulic elevator shall not be greater than what
percentage of the elevator operating speed in the down direction. Minimum is 110%

ASME A17.1-2004

2.19.4.7.5 - answer 140 % Max

What is the maximum speed allowed for a spring buffer

ASME A17.1-2004

2.22.1.1.1 - answer 200 fpm

When the quantity of hydraulic fluid loss can not be accounted for, which tests shall then be

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Favorgrades Chamberlain College Of Nursing
View profile
Follow You need to be logged in order to follow users or courses
Sold
758
Member since
3 year
Number of followers
374
Documents
29913
Last sold
1 day ago
Favorgrades Emporium

3.7

184 reviews

5
77
4
41
3
31
2
11
1
24

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their exams and reviewed by others who've used these revision notes.

Didn't get what you expected? Choose another document

No problem! You can straightaway pick a different document that better suits what you're after.

Pay as you like, start learning straight away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and smashed it. It really can be that simple.”

Alisha Student

Frequently asked questions