2026|2027 ACTUAL COMPLETE REAL EXAM QUESTIONS AND
CORRECT DETAILED ANSWERS (VERIFIED ANSWERS) ALREADY
GRADED A+ | GUARANTEED SUCCESS!! | HIGHLY
RECOMMENDED BY EXPERTS | NEW AND
REVISED | JUST RELEASED!!
While completing the preoperative assessment, a nurse notices
the pt R knee has been marked by the surgeon but the pt is
scheduled for the L Knee arthroplasty. What is the best action
for the nurse? - ANSWER-verify with the surgeon
A pt age 7 is scheduled for a tonsillectomy and adenoidectomy
at the ambulatory surgery center. During the preoperative
telephone interview, the mother asks the preoperative nurse if
her daughter will be able to take her favorite stuffed animal into
the OR. Which of the following is the best response based on
the child's developmental level - ANSWER-we will make sure
the toy stays with your daughter until the anesthetic takes
effect
a potential complication of epidural anesthesia caused by a/an
____ is complete paralysis requiring intubation and systemic
,support until the block is resolved - ANSWER-subarachnoid
injection
R/ Subarachnoid injection caused by the initial needle or an
epidural catheter that moves and punctures the subarachnoid
space may result in total paralysis. Injection of medications
should be done with a test dose1st followed by injections of up
to 5 mL at a time to ensure proper placement
the most accurate method for verifying the effectiveness of a
steam sterilizer is a - ANSWER-biologic indicator
which of the following should be considered regarding the
integrity of packing materials? - ANSWER-storage areas should
have air temperature below 75degrees Fahrenheit
R/ temp below 75F & humidity between 30-70% are
environmental conditions needed to help prevent the potential
for contamination. Storage should be secured away from
unrestricted conditions. Closed cupboards are preferable for
storage. Items should be cooled prior to storage
an EPA registered disinfectant labeled to kill tuberculosis is
effective against - ANSWER-mycobacteria
,when transporting instruments after a procedure, the ____
require that the instruments are put in a closed container or
closed cart - ANSWER-OSHA regulations
a reusable flexible neuroendoscope has been used for a pt who
is suspected of having Creutzfedt-Jakob Disease (CJD). The
safest way to process this neuroendoscope post-procedure is
to - ANSWER-dispose of the scope
R/ Shorter steam sterilization cycles and low temp sterilization
technique are not effective in inactivationg prions. When used
on high risk tissue, reusable instruments that are not easy to
clean and cannot tolerate extended steam sterilization cycles
should be discarded after use
to adequately decontaminate a flexible endoscope after use,
the 1st step that should be followed is to - ANSWER-preclean
the exterior with cleaning product
R/ precleaning at point of use should occur as soon as possible
after the endoscope is removed from the pt. the exterior of the
endoscope should be washed with an approved cleaning
solution before transport to the decontamination area for leak
testing and manual cleaning. Precleaning prevents drying of
organic material and formation of biofilm
, the FDA began the voluntary ____ program to encourage
physicians, nurses, pharmacists & other health care
professionals to report adverse events and defects or problems
with regulated drugs and devices - ANSWER-Medwatch
R/medwatch was developed to create a national standardized
reporting format for devices that have the potential for creating
harm
the perioperative nurse sterilizes a yankaur suction tip that has
been contaminated during the case. The temperature on the
print out tape for the gravity displacement steam sterilizer read
272 F ( 135C). the nurse's next action is to - ANSWER-return the
instrument to the sterile field in an aseptic fashion
R/ parameters for temperature for immediate use sterilization in
a gravity displacement steam sterilizer for metal items with
lumens are 270 to 272 F (132-135 C)
the purpose for placing a chemical indicator tape on the
outside of a package is to signify that the package - ANSWER-
an external chemical indicator should be checked to determine
that the package has been exposed to a sterilant.
R/The integrity of the package and expiration date, if applicable,
also determined the sterility of the contents