Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Document preview thumbnail
Preview 4 out of 45 pages
Exam (elaborations)

NICET LEVEL 2 NEWEST 2025 ACTUAL EXAM COMPLETE 100 QUESTIONS AND CORRECT DETAILED ANSWERS (VERIFIED ANSWERS) ALREADY GRADED A+ (BRAND NEW VERSION!).pdf

Document preview thumbnail
Preview 4 out of 45 pages

NICET LEVEL 2 NEWEST 2025 ACTUAL EXAM COMPLETE 100 QUESTIONS AND CORRECT DETAILED ANSWERS (VERIFIED ANSWERS) ALREADY GRADED A+ (BRAND NEW VERSION!).pdf

Content preview

1
NICET



NICET LEVEL 2 FIRE ALARMS (2024/ 2025 U PDA
M M M M M M M




TE) QS & AS| 100% CORRECT| G RADE A (VERIFIED
M M M M M M M M




ANSWERS) M




Whenmascendingmormdescendingm ammetalmladder,mthemclimberm mustm __________
____
A.mcountmthemsteps
B.mlookmdown
C.mfacemthemladder
D.mnonmofmthemabovem-mANSm✓C

Multiconductormnon-power-
limitedmfiremalarmmcircuitmcables,mTypesmNPLFP<mNPLFR,mandmNPLF,mshallmn
otmbeminstalledm______________m inmductsm-mANSm✓Exposed

Amfirem/burglarmalarmmsystemmwasminstalledmasmamcombinationmhouseholdmfi
remalarmmsystem.mWhichmofmthemfollowingmstatementsmism true:m
A.mThemfiremalarmmsignalmshallmtakemprecedencemovermthem burglarmalarmmsig
nal.m
B.mThemfiremalarmmsignalmandmthemburglarmalarmmsignalsmshallmbem distinctive
.m
C.mAmcommon-
soundingmappliancemcanmbemusedmifmthemsoundsmaremdistinctivemformbothmsig
nals.m
D.mAllmofmthemabovem-mANSm✓D

AccordingmtomthemIBC,mallmvalvesmcontrollingm themwater-
flowmswitchmformanmautomaticmsprinklermsystemmshallm______________m-
mANS m✓bemelectrically msupervised




FusesmformNPFLAm_______________mandmlargermshallmbemprovidedmwithmthemcond
uctormampacitymwithoutmapplyingmampacitymcorrectionmormadjustmentmfacto
rsm-mANSm✓14mAWG

Themwaterflow mswitchesmshallmhavem_______________mtime-
delayminmamsprinkleredmelevatormhoistmwaym-mANSm✓No


NICET LEVEL 2
m m

, 2
NICET

Amcarbonmmonoxidem(CO)mdetectormsignalmtakesmprecedencemover:m
A.mTroublemsignals
B.mSupervisorymsignals
C.mBothmTroublemandmSupervisorymsignals
D.mAlarmmSignalsm-mANSm✓C

Inmtermsmofmsprinkler,mwaterflow malarm-
initiatingmdevices,mactivationmofmthem initiatingmdevicemshallmoccurmwithinm___
__________mseconds.m-mANSm✓90mseconds

Whichmtypemofmdetectormismmostmsuitablemformprotectingm largemopenmareasmli
kemamgym?m-mANSm✓ProjectedmBeam

Ifmyoumaremtominstallmamnewmmessengermsupportedmwireminmanmarea,myoumma
ymdomallmofmthemfollowingmexcept?
A.mUsemamfactory-assembledmaerialmcable.
B.mUsemammessengermwiremwithmfieldminstalledmlashingmmaterialmformconduct
ormsupport.
C.mUsemammessengermwiremwithmwingsmandmsaddlesmformconductormsupport.
D.mAttachmtomampre-
existingmmessengermwiremifmitmismcarryingm themsamemtypemsystemmcabling.m-
mANS m✓D




AccordingmtomNFPAm72,mamhouseholdmfiremalarmmsystemmismrequiredmwhichm
ofmthemfollowing?
A.mSmokemdetectionmcircuitsmshallm notmbemrequiredmtomlockmin.
B.mResetmswitchesmmustmlatch.
C.mNAC'smaremnotmrequiredmtombemmonitored.
D.mAllmofmthemabove.m-mANSm✓A

Visualmappliancesmaremrequiredm inmanmareamifmthem averagemambientmsoundml
evelmismgreatermthanmamlevelmofmwhat?m-mANSm✓105mdBa

Equipmentmmustmbemengineeredmandmtestedmtomoperatemproperlymat_______of m
itsmnameplatemvoltage.m-mANSm✓85%

Whatmismthemmaximumm numbermofmbendm(inmdegrees)m permittedm inmRMCmbe
tweenmoutletmboxes?m-mANSm✓360mdegrees




NICET LEVEL 2
m m

, 3
NICET
Residentialmfiremalarmmsystemsmmustmhavemambackupmbatterymcapablemofmop
eratingmthemsystemmform________m hoursminmamnormalmconditionmandm__________m
min.minmalarmmcondition.m-mANSm✓24/4

A(n)_______msignalmwillmbemreceivedmwhenmthemsystemmormanymportionmofmthem
systemmatmthemprotectedmpremisesmismplacedminmambypassmormtestm mode.m-
mANS m✓Trouble




Unlessmspecificallymdefinedmbymthemcode,movermcurrentmprotectionmshallm notm
exceed____ampsmformam12mAWGmcoppermconductor.m-mANSm✓20

Ifmyoumaremrequiredmtominstallmamvisualm notificationmapplianceminmanm areamth
atmhasmamceilingmheightmofm6'6″,mwhatm ismthem maximummdistancemthemdevicem
canmbemmountedmfrommthemceiling?m-mANSm✓6"

Themsecondarympowermsupplymshallmautomaticallymprovidempowermtom thempr
otectedmpremisesmfiremalarmmsystemmwithin_______,mwhenevermthemprimarym p
owermsupplymfailsmtomprovidemthemminimumm voltagemrequiredmformpropermo
peration.m-mANSm✓10mseconds

Cablemthatmismdesignatedmasm directmburiedmcablem ismnotmrequiredmtom bemmor
emthan_______below mground.m(0vmtom600v)m-mANSm✓24"

Whatmismthemminimummallowablem AWGmformamclassm3mconductor?m-
mANS m✓18mAWG




WhatmtypemofmfiremalarmmsystemmrequiresmthemFAmcontractormtomattachmamlab
elmdocumentingmthemtypemofmservicemtomthemFACP?

ProprietarymSystem
LocalmSystem
RemotemStation
CentralmStationm-mANSm✓Central mStation

Somemsmokemdetectorsmhavemamprovisionmformamfieldmadjustmentmofmsensitiv
itymandmtheymaremrequiredm tomhavem anmadjustmentmrangemofmnotmlessm than___
____mpermfootmofmobscuration.m-mANSm✓0.6%

WhatmismthemmaximummsizemgroundingmconductormallowedmformamCATVminst
allation?m-mANSm✓6mAWG



NICET LEVEL 2
m m

, 4
NICET
Duringmthemtestingmofmmanualmfiremalarmmboxes,myoumobservemthem manualmfi
remalarmmboxesmhavemprotectivemcoversmthatm emitmamlocalmalarmmsignal.mAcc
ordingmtomthemIBC,mprotectivemcoversmwithmlocalmalarmmsignallingmrequiresm_
____?

AHJmapproval
Opaquemcovers
ULm864mlisting
Protectionmfrommunauthorizedm usem-mANSm✓AHJmapproval

Whichmofmthemfollowingmtermsmbestmdescribesmthemfollowingmphrase;manmele
ctricalmcircuitmthatmismusedmtomenergizemsignallingmequipment.?m

remotemcontrolmcircuit
signallingmcircuit
leadmcircuit
primarymcircuitm-mANSm✓signallingmcircuit

Whatmismthemminimummmountingmheightmformanmaudiblem notificationmapplia
nce?m-mANSm✓90"

Whichmofmthemfollowingmismnotmanminitiatingm device?

Electromechanicalmreleasingmdevice
McCullohmtransmitter
Watermlevelmswitch
Smokemdetectorm-mANSm✓McCullohmtransmitter

AmGroupmBmAmbulatorymcaremfacilitymshallmbemprovidedmwithmanmelectronica
llymsupervisedm_____minstalledmwithinm them ambulatorymcaremfacilitymandminmp
ublicmusemareasmoutsidemtenantmspaces?

Automaticmsmokemdetectionmsystem
Automaticmsprinklermsystem
Manualmfiremalarmmsystem
Notificationmappliancesm-mANSm✓Automatic mSmokemDetection mSystem

WhichmofmthemfollowingmdescriptionsmwouldmNOTmbem consideredm amqualified
msystemmdesigner? m




A.mAmpersonmwhomismcertifiedmbymamstatemauthority.



NICET LEVEL 2
m m

Connected book
 image
Publisher: 2016 ISBN: 9781523321087 Edition: Unknown

Document information

Uploaded on
March 25, 2025
Number of pages
45
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
CA$29.99
Purchased by 2 students

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
REVISIONGENIUS
4.8
(983)
Sold
25
Followers
0
Items
501
Last sold
3 weeks ago


Reviews from verified buyers




Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions