Fdny A35 Exam Questions and Answers Verified 100% Correct Maintenance & Repairing Compressor- General Requirements - ANSWER - always follow guidelines outlined by manufacturer. Repair: -always turned off -electrical supply shutdown -air drained -made by qualified technician Repairs by CF - ANSWER --must know how to correct cooling system; -may replace belts -change air filter -change lubrication oil Leaks - ANSWER -CF must look & listen for leaks. More prominent in colder months when sealing materials shrink. Most leakage occurs at tubing and fittings at air reciever tank. Heat & Compressor - ANSWER --never place combustible materials nearby; -do not use near devices that produce heat; solar heat is not known to cause overheating CF Responsibility - ANSWER --visually inspect -remain in area for a few minutes after compressor started -do not operate at speeds above recommended ranged Injury from Compressor - ANSWER --Dust or debris blow off clothing can be driven under skin causing DEATH -Eardrum ruptures at 40 PSI -Air entering mouth can destroy lungs and internal organs -Eyesight (always wear googles) Hydrostatic testing - ANSWER -Fire Code no longer requires affidavit indicating reciever is hydrostactically tested and defect free. HOWEVER, test every 5 years at a minimum is reccomended. Cleaning Compressor - ANSWER -only using soap and water solution. NEVER use benzene, kerosene or other light oils for this purpose. They may cause an explosion when mixed w/ air under pressure. Both oil and water can cause an explosion if they actually enter the compressor tank. Maintenance-Cooling System - ANSWER -Tested every 6 months. Water supply control valves always open when compressor in operation Maintenance-Air Intake Filter - ANSWER -Inspected/cleaned weekly. Replaced every 6 months. Replace if damaged Maintenance-Lubrication Oil - ANSWER -Level checked weekly using dipstick Replaced every 6 months Refer to manufacturer manual for safe operating temperatures of oil and grade of oil needed. Maintenance-Automatic Low level Oil Indicator Switch - ANSWER -Tested every 3 months by manually draining oil from compressor. Do not run compressor for a long period of time when testing this way. Maintenance-Air Reciever - ANSWER -Tested every 5 years by qualified technician Water buildup in moisture separator assembly and air receiver drained daily by opening drain valve EXCEPT when temperature below 40 degrees Safety valves should be manually operated every week. Maintenance-Hose Connections - ANSWER -Make sure tight, frequently. Never twist, bend, curl to stop it. Do not patch w/ duct tape. Maintenance-Belts - ANSWER -Turn off compressor and disconnect power supply. If visibly damaged or frayed, replace. To test tension, firmly press on belt. If it moves more than 1 inch, fly wheel needs to be adjusted. If this doesn't work replace belts. Maintenance-Electrical Connections - ANSWER -Visually inspect. Notify electrician if evidence of defective parts. Special attention to motor starter (protects agst. thermal overload caused by excessive currents). Maintenance-Pressure Switch - ANSWER -1. Star compressor, allow air in receiver to build to normal operating levels while paying attention to gauge. 2. When gauge indicates pressure above normal, compressor should shut down automatically. If not, pressures witch may be adjusted. If this doesn't work switch is defective and MUST be replaced. **SOME compressors operate continuously as their pressure switch device just prevents compressor from compressing air. to test this just make sure air is no longer compressing when level is reached. Maintenance-Pressure Relief Valve - ANSWER -Run compressor w/ pressure switch fully open (when it is in this position it CANNOT shut down the compressor). Should be set at NO LESS than 15 psi OR 10% above the operating pressure of the compressor (which ever is greater) BUT NEVER higher than max allowabe working pressure of receiver.

Mostrar más Leer menos
Institución
Fdny A35
Grado
Fdny A35









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Fdny A35
Grado
Fdny A35

Información del documento

Subido en
7 de noviembre de 2025
Número de páginas
8
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

Fdny A35 Exam Questions and Answers
Verified 100% Correct

Maintenance & Repairing Compressor- General Requirements - ANSWER --
always follow guidelines outlined by manufacturer.

Repair:
-always turned off
-electrical supply shutdown
-air drained
-made by qualified technician

Repairs by CF - ANSWER --must know how to correct cooling system;
-may replace belts
-change air filter
-change lubrication oil

Leaks - ANSWER -CF must look & listen for leaks.

More prominent in colder months when sealing materials shrink.

Most leakage occurs at tubing and fittings at air reciever tank.

Heat & Compressor - ANSWER --never place combustible materials nearby;
-do not use near devices that produce heat;

solar heat is not known to cause overheating

CF Responsibility - ANSWER --visually inspect
-remain in area for a few minutes after compressor started
-do not operate at speeds above recommended ranged

Injury from Compressor - ANSWER --Dust or debris blow off clothing can be
driven under skin causing DEATH
-Eardrum ruptures at 40 PSI
-Air entering mouth can destroy lungs and internal organs
-Eyesight (always wear googles)

, Hydrostatic testing - ANSWER -Fire Code no longer requires affidavit indicating
reciever is hydrostactically tested and defect free.

HOWEVER, test every 5 years at a minimum is reccomended.

Cleaning Compressor - ANSWER -only using soap and water solution.

NEVER use benzene, kerosene or other light oils for this purpose. They may cause
an explosion when mixed w/ air under pressure.

Both oil and water can cause an explosion if they actually enter the compressor
tank.

Maintenance-Cooling System - ANSWER -Tested every 6 months.

Water supply control valves always open when compressor in operation

Maintenance-Air Intake Filter - ANSWER -Inspected/cleaned weekly.

Replaced every 6 months.

Replace if damaged

Maintenance-Lubrication Oil - ANSWER -Level checked weekly using dipstick

Replaced every 6 months

Refer to manufacturer manual for safe operating temperatures of oil and grade of
oil needed.

Maintenance-Automatic Low level Oil Indicator Switch - ANSWER -Tested every
3 months by manually draining oil from compressor. Do not run compressor for a
long period of time when testing this way.

Maintenance-Air Reciever - ANSWER -Tested every 5 years by qualified
technician

Water buildup in moisture separator assembly and air receiver drained daily by
opening drain valve EXCEPT when temperature below 40 degrees
$10.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor
Seller avatar
TopGradeGuru
1.5
(2)

Conoce al vendedor

Seller avatar
TopGradeGuru Teachme2-tutor
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
10
Miembro desde
1 año
Número de seguidores
0
Documentos
2429
Última venta
1 mes hace
GRADEHUB

We provide access to a wide range of professionally curated exams for students and educators. It offers high-quality, up-to-date assessment materials tailored to various subjects and academic levels. With instant downloads and affordable pricing, it's the go-to resource for exam preparation and academic success.

1.5

2 reseñas

5
0
4
0
3
0
2
1
1
1

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes