100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

ACI Grade I Field Testing Certification Practice Test (Complete And Verified Study material)

Puntuación
-
Vendido
-
Páginas
21
Grado
A+
Subido en
06-11-2025
Escrito en
2025/2026

ACI Grade I Field Testing Certification Practice Test (Complete And Verified Study material)

Institución
ACI Grade I Field Testing Certification
Grado
ACI Grade I Field Testing Certification










Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
ACI Grade I Field Testing Certification
Grado
ACI Grade I Field Testing Certification

Información del documento

Subido en
6 de noviembre de 2025
Número de páginas
21
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

ACI Grade I Field Testing
Certification Practice Test
(Complete And Verified Study
material)




The temperature measuring device must be accurate to within
0.1° ( true or false) - ✔✔ANSWER✔✔-False 1°F or 0.5°C

The temperature measuring device shall have a capacity of
measuring temperature of freshly mixed concrete throughout a
range of ____ to ___F - ✔✔ANSWER✔✔-30° to 120°F
For concrete with aggregates less than 3 inches, the
thermometer must remain in the fresh concrete sample a.
Minimum of 5 minutes or until temperature reading stabilizes.
(True or false) - ✔✔ANSWER✔✔-False( 2 minutes but not
more than 5)


A composite sample is not needed if only the temperature test
is being run( T or F) - ✔✔ANSWER✔✔-True

The temperature of fresh concrete in a placement must be
measured by inserting a thermometer into the top six inches of

,concrete.( T or F) - ✔✔ANSWER✔✔-False (does not specify
aggregate size)

ASTM C1064 states the container used to measure
temperature of concrete must be large enough to provide at
least 5 inches of concrete. ( T or F) - ✔✔ANSWER✔✔-False (
3 inches or must be 3x the nominal max size)


The maximum allowable time between obtaining the first and
last portions of the composite sample may not exceed 5
minutes (t or F) - ✔✔ANSWER✔✔-False 15 minutes

Start molding specimens for strength tests within 30 minutes
after fabricating the composite sample(T or F) -
✔✔ANSWER✔✔-False (15 minutes )

The composite concrete sample must be protected from the
sun, wind, contamination and rapid evaporation (T or F) -
✔✔ANSWER✔✔-True

If the concrete contains aggregate larger than those that are
appropriate for a size of mold or equipment used, the sample
should be wet sieved before making the test (T or F) -
✔✔ANSWER✔✔-True
For concrete with aggregates less than 3 inches, the
thermometer must remain in the fresh concrete sample a.
Minimum of 5 minutes or until temperature reading stabilizes.
(True or false) - ✔✔ANSWER✔✔-False( 2 minutes but not
more than 5)

The temperature measuring device must be accurate to within
0.1° ( true or false) - ✔✔ANSWER✔✔-False 1°F or 0.5°C

, The temperature measuring device shall have a capacity of
measuring temperature of freshly mixed concrete throughout a
range of ____ to ___F - ✔✔ANSWER✔✔-30° to 120°F

A composite sample is not needed if only the temperature test
is being run( T or F) - ✔✔ANSWER✔✔-True

The temperature of fresh concrete in a placement must be
measured by inserting a thermometer into the top six inches of
concrete.( T or F) - ✔✔ANSWER✔✔-False (does not specify
aggregate size)

ASTM C1064 states the container used to measure
temperature of concrete must be large enough to provide at
least 5 inches of concrete. ( T or F) - ✔✔ANSWER✔✔-False (
3 inches or must be 3x the nominal max size)

The temperature of the concrete is recorded to the nearest
__°F - ✔✔ANSWER✔✔-1°F

Calibrate the temperature measuring device at least ___, or
whenever there is a question of accuracy - ✔✔ANSWER✔✔-
Annually

After the thermometer is placed in the concrete: -
✔✔ANSWER✔✔-Gently press concrete around the
thermometer.

According to ASTM C1064, what is one reason to take the
temperature of concrete? - ✔✔ANSWER✔✔-Verify
conformance

It is allowable to remove the temperature measuring devices
from the freshly mixed concrete to read the temperature if you
cannot see the reading (T or F) - ✔✔ANSWER✔✔-False

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
WORLDNURSE Chamberlain College Of Nursing
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
161
Miembro desde
2 año
Número de seguidores
41
Documentos
3405
Última venta
6 días hace
STUDY TOP EXAMS

.Welcome to my academic support store, your trusted destination for top-tier homework help and tutoring services! Specializing in key subjects like Psychology, Nursing, Human Resource Management, and Mathematics, I’m dedicated to helping students excel with high-quality, meticulously crafted resources. My mission is to deliver scholarly, reliable content that guarantees excellent grades, earning me a reputation as one of Stuvia’s BEST GOLD RATED TUTORS. Whether you need assistance with quizzes, exams, or detailed study materials, I prioritize your success with a commitment to academic excellence and results you can count on.

Lee mas Leer menos
5.0

2358 reseñas

5
2325
4
13
3
8
2
4
1
8

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes