Ohm's Law Relationship of voltage, current, and resistance. Current in Series Circuit Total current equals voltage divided by resistance. Sound Pressure Level Maximum allowable dBA for audible alarms. Radiant Energy Detectors Devices detecting ionization, photoelectric, heat, or flame. Detector Spacing Rule Detector must be within 1 to 5 times spacing. Power Sources for Fire Alarms Minimum of two independent and reliable power sources. Telephone Appliance Height Wall-mounted phones must be ≤ 66 inches high.

Mostrar más Leer menos
Institución
FLSD
Grado
FLSD









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
FLSD
Grado
FLSD

Información del documento

Subido en
23 de octubre de 2025
Número de páginas
13
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

Fire Life Safety Exam Preparation
questions and answers
Ohm's Law ✔✔Relationship of voltage, current, and resistance.

Current in Series Circuit ✔✔Total current equals voltage divided by resistance.

Sound Pressure Level ✔✔Maximum allowable dBA for audible alarms.

Radiant Energy Detectors ✔✔Devices detecting ionization, photoelectric, heat, or flame.

Detector Spacing Rule ✔✔Detector must be within 1 to 5 times spacing.

Power Sources for Fire Alarms ✔✔Minimum of two independent and reliable power
sources.

Telephone Appliance Height ✔✔Wall-mounted phones must be ≤ 66 inches high.

Current in Parallel Circuit ✔✔Total current equals sum of branch currents.

Signaling Line Circuit ✔✔Carries multiple input and output signals.

Notification Appliance Purpose ✔✔Alerts occupants during a fire emergency.

Circuit Disconnect Identification ✔✔Must be marked at the power supply.

Alarm Activation Time ✔✔Must activate within 5 seconds of triggering.

Manual Fire Box Travel Distance ✔✔Must be within 200 feet of each other.

Current Flow Observation ✔✔Indicates voltage polarity in a circuit.

Circuit Integrity Rating ✔✔Minimum fire resistance rating of 2 hours.

Grounding Pipe Depth ✔✔Water pipe must be buried 10 feet deep.

Battery Recharge Time ✔✔Recharge within 24 hours after discharge.

Battery Date Requirement ✔✔Must display month/year on booster panel.

, Ground Fault Delay Time ✔✔Delay set at 90 seconds at main panel.

Ceiling Smoothness Criteria ✔✔Beams must not project more than 4 inches.

Alarm Signal Duration ✔✔Must last at least 5 minutes.

Circuit Integrity Monitoring ✔✔Monitored by voltage loss or small current.

Conductor Size Requirement ✔✔Stranded conductors for sizes 6 AWG or larger.

Smoke Detector Temperature Limit ✔✔Cannot be installed below 32 degrees
Fahrenheit.

Minimum Grounding Conductor Size ✔✔Telecommunications circuits require #10
grounding conductor.

Central Station Power Supply ✔✔Must provide 24 hours standby and 5 minutes alarm.

Smoke detectors testing frequency ✔✔Tested weekly, monthly, quarterly, or annually.

Fire alarm notification appliances ✔✔Includes bells, horns, strobes, LCD displays.

Minimum smoke alarms in dwelling ✔✔A 2-story home requires at least 3 alarms.

Water temperature supervisory device ✔✔Signals below 32 degrees F for freezing
conditions.

Class A circuits ✔✔Outgoing and return conductors in one conduit.

Wet pipe sprinkler system supervision ✔✔Monitors air pressure and valve position.

Waterflow switches testing frequency ✔✔Tested weekly, monthly, quarterly,
semiannually, or annually.

Heat-sensing fire detector classification ✔✔175 - 249 degrees F is medium
temperature.

Visible notification appliances spacing ✔✔Maximum 15 ft apart, not exceeding 100 ft.

Notification appliance circuit condition ✔✔Reverse polarity indicates alarm condition.

Off-normal suppression system indication ✔✔Alarm, trouble, or supervisory signal
alerts.
$12.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor
Seller avatar
Gnurse

Conoce al vendedor

Seller avatar
Gnurse NEWCASTLE UNIVERSITY
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
0
Miembro desde
1 año
Número de seguidores
0
Documentos
213
Última venta
-

0.0

0 reseñas

5
0
4
0
3
0
2
0
1
0

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes