Certified Rhythm Analysis Technician Training Overview EXAM
QUESTIONS AND VERIFIED SOLUTIONS | ELABORATED & DETAILED
ANSWERS!!
Certified Rhythm Analysis Technician - correct answer A professional trained to analyze cardiac
rhythms.
HIPPA - correct answer The Health Insurance Portability and Accountability Act, established in
1996 to protect the privacy and security of health information transferred electronically.
OSHA - correct answer Occupational Safety and Health Administration, which creates and
enforces regulations concerning workplace safety.
Medical Ethics - correct answer Standards of behavior based on moral values that dictate right
or wrong conduct in healthcare.
Informed Consent - correct answer A process requiring the patient to be informed of a
procedure and its risks before signing a consent form.
Implied Consent - correct answer Consent that is assumed based on a patient's actions, such as
agreeing to treatment by visiting a physician.
Myocardial Infarction (MI) - correct answer Damage to the heart muscle caused by lack of
oxygen due to a blockage of one or more coronary arteries, also known as a heart attack.
Electrocardiograph - correct answer An instrument used to record the electrical activity of the
heart.
Electrocardiogram (ECG) - correct answer A tracing of the heart's electrical activity recorded by
an electrocardiograph.
Code Blue - correct answer An alert that notifies healthcare providers that a patient is
unresponsive and needs immediate assistance.
Stat - correct answer A term meaning immediately.
Defibrillator - correct answer A battery-powered device that delivers an electric shock to
restore a normal heartbeat during chaotic heart rhythms.
Automatic External Defibrillator - correct answer A lightweight, portable device used in
emergencies to recognize abnormal heart rhythms and deliver defibrillation.
Dysrhythmia - correct answer An abnormal heartbeat.
Telemedicine - correct answer A system that communicates ECG tracings from a patient outside
a medical facility to a physician via telephone or digital systems.
,Telemetry (Hospital) - correct answer An in-hospital cardiac monitoring system that allows
patients to move while being monitored.
Patient Safety - correct answer The practice of ensuring the well-being of patients during
medical procedures and treatments.
Medical Professional Liability - correct answer The legal responsibility of healthcare
professionals for their performance and actions.
Breach of Confidentiality - correct answer The unauthorized disclosure of patient information,
which is both unethical and illegal.
Regulatory and Compliance Standards - correct answer Guidelines and regulations that
healthcare professionals must follow to ensure legal and ethical practices.
Medical Terminology - correct answer The specialized language used in the healthcare field to
describe medical conditions, procedures, and equipment.
Patient Consent - correct answer The agreement by a patient to undergo a medical procedure
after being informed of the risks and benefits.
Healthcare Professionals - correct answer Individuals who provide medical services, including
doctors, nurses, and technicians.
Confidentiality - correct answer The ethical principle of keeping patient information private and
secure.
Respect and Dignity - correct answer The treatment of all patients with consideration and
honor, fundamental to ethical healthcare practice.
Third-party Presence - correct answer The requirement for an additional person to be present
during certain medical procedures for patient safety.
Electrocardiograph (ECG) Technician - correct answer An individual who has the technical
knowledge and skills to record an ECG and prepare it for the physician.
ECG Monitor Technician (Telemetry) - correct answer An individual who has the technical
knowledge and skills to view and evaluate the electrical tracings of the patient's heart on a
monitor, and when necessary, alert the appropriate healthcare professional to treat
abnormalities.
Cardiovascular Technologist - correct answer An individual who has advanced skills and can
assist physicians with invasive cardiovascular diagnostic tests, such as angioplasty or heart
surgery.
Synchronous - correct answer Identical, coming from the same focus in the heart.
Asynchronous - correct answer Different, varies, coming from different foci in the heart.
, Variable Rate - correct answer Inconsistent or irregular heart rate; different number of waves
between each QRS.
Fixed Rate - correct answer Consistent or regular heart rate; the same number of waves
between each QRS.
Escape Rhythm - correct answer A term used when the sinus node slows down or fails to
initiate depolarization and a lower pacemaker site produces electrical impulses, assuming
responsibility for pacing the heart.
Einthoven Triangle - correct answer A triangle formed by 3 of the limb electrodes (the left arm,
right arm, and left leg) used as a reference for the first 6 leads of the 12 lead ECG.
Electrodes - correct answer Small sensors placed on the skin to detect the electrical activity of
the heart.
Leads - correct answer Covered wires that conduct the electrical impulse from the electrodes to
the ECG machine; also refers to the view on the ECG tracing as well as the physical location
where the electrode is placed on the patient.
Standard Limb Leads - correct answer Leads that are attached to the arms and legs; bipolar
leads because they measure the flow of electrical current in both directions at the same time.
Lead I - correct answer Records the tracing from the right arm (-) to the left arm (+).
Lead II - correct answer Records the tracing from the right arm (-) to the left leg (+).
Lead III - correct answer Records the tracing from the left arm (-) to the left leg (+).
Augmented Leads - correct answer Normally small ECG tracings that are increased in size by the
ECG machine in order to be interpreted; unipolar leads because they measure towards one
electrode on the body.
aVR - correct answer Records electrical activity from the heart to the right arm; usually shows a
negative deflection.
aVL - correct answer Records electrical activity from the heart to the left arm.
aVF - correct answer Records electrical activity from the heart to the left leg.
Chest Leads - correct answer Also known as precordial leads; placed on the anterior chest wall.
V1 - correct answer Placed on the fourth intercostal space, right sternal border.
V2 - correct answer Placed on the fourth intercostal space, left sternal border.
V3 - correct answer Placed halfway between V2 and V4.
V4 - correct answer Placed on the fifth intercostal space at the midclavicular line.
QUESTIONS AND VERIFIED SOLUTIONS | ELABORATED & DETAILED
ANSWERS!!
Certified Rhythm Analysis Technician - correct answer A professional trained to analyze cardiac
rhythms.
HIPPA - correct answer The Health Insurance Portability and Accountability Act, established in
1996 to protect the privacy and security of health information transferred electronically.
OSHA - correct answer Occupational Safety and Health Administration, which creates and
enforces regulations concerning workplace safety.
Medical Ethics - correct answer Standards of behavior based on moral values that dictate right
or wrong conduct in healthcare.
Informed Consent - correct answer A process requiring the patient to be informed of a
procedure and its risks before signing a consent form.
Implied Consent - correct answer Consent that is assumed based on a patient's actions, such as
agreeing to treatment by visiting a physician.
Myocardial Infarction (MI) - correct answer Damage to the heart muscle caused by lack of
oxygen due to a blockage of one or more coronary arteries, also known as a heart attack.
Electrocardiograph - correct answer An instrument used to record the electrical activity of the
heart.
Electrocardiogram (ECG) - correct answer A tracing of the heart's electrical activity recorded by
an electrocardiograph.
Code Blue - correct answer An alert that notifies healthcare providers that a patient is
unresponsive and needs immediate assistance.
Stat - correct answer A term meaning immediately.
Defibrillator - correct answer A battery-powered device that delivers an electric shock to
restore a normal heartbeat during chaotic heart rhythms.
Automatic External Defibrillator - correct answer A lightweight, portable device used in
emergencies to recognize abnormal heart rhythms and deliver defibrillation.
Dysrhythmia - correct answer An abnormal heartbeat.
Telemedicine - correct answer A system that communicates ECG tracings from a patient outside
a medical facility to a physician via telephone or digital systems.
,Telemetry (Hospital) - correct answer An in-hospital cardiac monitoring system that allows
patients to move while being monitored.
Patient Safety - correct answer The practice of ensuring the well-being of patients during
medical procedures and treatments.
Medical Professional Liability - correct answer The legal responsibility of healthcare
professionals for their performance and actions.
Breach of Confidentiality - correct answer The unauthorized disclosure of patient information,
which is both unethical and illegal.
Regulatory and Compliance Standards - correct answer Guidelines and regulations that
healthcare professionals must follow to ensure legal and ethical practices.
Medical Terminology - correct answer The specialized language used in the healthcare field to
describe medical conditions, procedures, and equipment.
Patient Consent - correct answer The agreement by a patient to undergo a medical procedure
after being informed of the risks and benefits.
Healthcare Professionals - correct answer Individuals who provide medical services, including
doctors, nurses, and technicians.
Confidentiality - correct answer The ethical principle of keeping patient information private and
secure.
Respect and Dignity - correct answer The treatment of all patients with consideration and
honor, fundamental to ethical healthcare practice.
Third-party Presence - correct answer The requirement for an additional person to be present
during certain medical procedures for patient safety.
Electrocardiograph (ECG) Technician - correct answer An individual who has the technical
knowledge and skills to record an ECG and prepare it for the physician.
ECG Monitor Technician (Telemetry) - correct answer An individual who has the technical
knowledge and skills to view and evaluate the electrical tracings of the patient's heart on a
monitor, and when necessary, alert the appropriate healthcare professional to treat
abnormalities.
Cardiovascular Technologist - correct answer An individual who has advanced skills and can
assist physicians with invasive cardiovascular diagnostic tests, such as angioplasty or heart
surgery.
Synchronous - correct answer Identical, coming from the same focus in the heart.
Asynchronous - correct answer Different, varies, coming from different foci in the heart.
, Variable Rate - correct answer Inconsistent or irregular heart rate; different number of waves
between each QRS.
Fixed Rate - correct answer Consistent or regular heart rate; the same number of waves
between each QRS.
Escape Rhythm - correct answer A term used when the sinus node slows down or fails to
initiate depolarization and a lower pacemaker site produces electrical impulses, assuming
responsibility for pacing the heart.
Einthoven Triangle - correct answer A triangle formed by 3 of the limb electrodes (the left arm,
right arm, and left leg) used as a reference for the first 6 leads of the 12 lead ECG.
Electrodes - correct answer Small sensors placed on the skin to detect the electrical activity of
the heart.
Leads - correct answer Covered wires that conduct the electrical impulse from the electrodes to
the ECG machine; also refers to the view on the ECG tracing as well as the physical location
where the electrode is placed on the patient.
Standard Limb Leads - correct answer Leads that are attached to the arms and legs; bipolar
leads because they measure the flow of electrical current in both directions at the same time.
Lead I - correct answer Records the tracing from the right arm (-) to the left arm (+).
Lead II - correct answer Records the tracing from the right arm (-) to the left leg (+).
Lead III - correct answer Records the tracing from the left arm (-) to the left leg (+).
Augmented Leads - correct answer Normally small ECG tracings that are increased in size by the
ECG machine in order to be interpreted; unipolar leads because they measure towards one
electrode on the body.
aVR - correct answer Records electrical activity from the heart to the right arm; usually shows a
negative deflection.
aVL - correct answer Records electrical activity from the heart to the left arm.
aVF - correct answer Records electrical activity from the heart to the left leg.
Chest Leads - correct answer Also known as precordial leads; placed on the anterior chest wall.
V1 - correct answer Placed on the fourth intercostal space, right sternal border.
V2 - correct answer Placed on the fourth intercostal space, left sternal border.
V3 - correct answer Placed halfway between V2 and V4.
V4 - correct answer Placed on the fifth intercostal space at the midclavicular line.