100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

BACKFLOW PREVENTION ASSEMBLY TESTER EXAM PRACTICE QUESTIONS & CORRECT ANSWERS LATEST 2025

Puntuación
-
Vendido
-
Páginas
31
Grado
A+
Subido en
05-10-2025
Escrito en
2025/2026

BACKFLOW PREVENTION ASSEMBLY TESTER EXAM PRACTICE QUESTIONS & CORRECT ANSWERS LATEST 2025

Institución
BACKFLOW PREVENTION ASSEMBLY
Grado
BACKFLOW PREVENTION ASSEMBLY











Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
BACKFLOW PREVENTION ASSEMBLY
Grado
BACKFLOW PREVENTION ASSEMBLY

Información del documento

Subido en
5 de octubre de 2025
Número de páginas
31
Escrito en
2025/2026
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

  • backflow prevention

Vista previa del contenido

BACKFLOW PREVENTION ASSEMBLY TESTER
EXAM PRACTICE QUESTIONS & CORRECT
ANSWERS LATEST 2025




In responding to a backflow incident the water purveyor should


(A) Call the mayor
(B) Implement the emergency response plan
(C) Install a vacuum breaker
(D) Develop a good excuse - ANSWER-Implement the emergency response plan


A mixture of air and gas is considered hazardous when the mixture exceeds what
percentage of the lower explosive limit


(A) 0%
(B) 3%
(C) 7%
(D) 10% - ANSWER-10%


To exert a pressure of 1.0 psi at base of a water column the column would have to
be


(A) 4.34 high

,(B) 14.7 high
(C) 27.75 high
(D) 33.89 high - ANSWER-27.75 high


A DC must be tested


(A) Upon installation
(B) Every 6 month
(C) Annually on a health hazard
(D) none of the above - ANSWER-Upon installation


An absolute pressure of 25 psiaa (at sea level) is equal to approximately


(A) 5 psi
(B) 10 psi
(C) 20 psi
(D) 25 psi - ANSWER-10 psi


During a field test the air inlet on PVB must open at


(A) Above 2.0 psid
(B) Below 1.0 psid
(C) Above 1.0 psid
(D) Below 2.0 psid - ANSWER-Above 1.0 psid

,A differential pressure gauge is used to field test


(A) PVB's
(B) Dual Checks
(C) AVB's
(D) All the above - ANSWER-PVB's


Backflow in a water supply can be caused by


(A) Backpressure only
(B) A Barometric Loop
(C) Backsiphonage only
(D) Backpressure and Backsiphonage - ANSWER-Backpressure and Backsiphonage


A BPAT tester is required to report test information on the proper forms to the


(A) Administrative authority
(B) Manufacturer's Rep
(C) EPA
(D) None of the above - ANSWER-Administrative authority


The relief valve opens when closing #2 shut off valve on a RP What is the most
probable cause

, (A) #1 Shut off valve is open
(B) #2 Shut off valve is open
(C) #1 check is fouled open
(D) Shut off is leaking - ANSWER-#1 check is fouled open


When field testing the #1 Check of a RP the differential pressurw shouid be


(A) Greater than or equal to 5.0 psid
(B) 3.0 psid greater than the relief valve opening point
(C) 1.0 psid in the direction of flow
(D) Less than 5.0 psid - ANSWER-Greater than or equal to 5.0 psid


When testing a SVB what is the first test being performed


(A) The air inlet opening point
(B) The static pressure across the check valve
(C) To verify the #2shut off hold tight
(D) To check if the SVB hold water - ANSWER-The static pressure across the check
valve


When testing a PVB the air inlet opens upon closing the #1 shut off valve What is
the most probable cause


(A) Leaking #2 shut off valve
(B) Leaking #1 shut off valve
$20.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
NurseSue Johns Hopkins University
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
49
Miembro desde
2 año
Número de seguidores
4
Documentos
1010
Última venta
2 meses hace

3.9

8 reseñas

5
4
4
1
3
2
2
0
1
1

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes