100% de satisfacción garantizada Inmediatamente disponible después del pago Tanto en línea como en PDF No estas atado a nada 4,6 TrustPilot
logo-home
Examen

Asphalt Paving LEVEL 2 QUESTIONS AND ANSWERS (VERIFIED 100%)

Puntuación
-
Vendido
-
Páginas
21
Grado
A+
Subido en
14-05-2025
Escrito en
2024/2025

Asphalt Paving LEVEL 2 QUESTIONS AND ANSWERS (VERIFIED 100%) What is the calculated application rate? (lbs/sq yds) - ANSWER (E.) 164.0 lbs/sq yds Given: Target Spread Rate: 165 lbs/Sq yds Given: Truck Weights (tons): 18.2, 19.63, 17.56, 18.78, 19.55 Given: Lane R1, Lift 1 Given: Start Station: 5+98 End Station: 13+60 Given: Lane Width: 13.5 feet What do you do? (Spread Rate) - ANSWER (A.) Spread Rate is in tolerance - document and continue Properly operated, the __ should be moving 80%-90% of the time while paving. - ANSWER (C.) Augers Cover Stone for an ARMI layer must be applied at what application rate? A. 0.6 to 0.8 ft³/yd² B. 0.26 to 0.33 ft³/yd² C. 0.34 to 0.57 ft³/yd² D. 0.02 to 0.08 ft³/yd² E. Not a specification requirement - ANSWER (B.) 0.26 to 0.33 ft³/yd² (T/F:) Increasing the layer thickness affects the time available for compaction more than increasing the mix temperature. - ANSWER True Using the classroom Project Core Layout Example - Method B from Module 8 - What are the station numbers for Cores 3-2-1 (576 tons) and 3-2-2 (673 tons)? Given Information: Starting Sta. is 10+00, Paving direction is "Up-Station", Spread rate is 165 lbs/yd², lane width is 12 feet - ANSWER (C.) 52+36, 61+18 Calculate the tack spread rate using the chart from Appendix 1. Given Information: Type of Tack RS-1h, Mix being placed on milled surface. Complete the calculations using the given information. What is the calculated application rate? (gal/yd²) Ending Sta.: 103+60; Beginning Sta.: 87+42; End Reading: 26/6; Beginning Reading: 22/1; Width of Application: 12 feet; Temp of Tack (Emulsified): 180°F - ANSWER 0.05 gal/yd² Calculate the tack spread rate using the chart from Appendix 1. Given Information: Type of Tack RS-1h, Mix being placed on milled surface. Complete the calculations using the given information. What do you do? Ending Sta.: 103+60; Beginning Sta.: 87+42; End Reading: 26/6; Beginning Reading: 22/1; Width of Application: 12 feet; Temp of Tack (Emulsified): 180°F - ANSWER (C.) Spread rate is in specification - document and continue Which technique(s) will produce a smoother mat? A. Emptying the truck in front of the paver B. Hot stop and start the paver C. Wait until the 3rd time before acting D. Increase the frequency of testing until the situation improves E. Both A and D - ANSWER (B.) Hot stop and start the paver If two consecutive QC density sublots for a fine graded mix do not meet the requirements of the table 334-5 Master Production Range: A. Make adjustments and continue B. Terminate the Lot C. Wait until the 3rd time before acting D. Increase the frequency of testing until the situation improves E. Both A and D - ANSWER (B.) Terminate the Lot (T/F:) When the total quantity of hot mix asphalt for the project, as indicated on the plans for Type SP and Type FC mixtures only, is less than 2000 tons, the Engineer will accept the mix on the basis of visual inspection, the Engineer may run acceptance tests to determine the acceptability of the material. - ANSWER True If the resolution test results compare favorably with the Contractor's QC test results: A. The Lot is accepted at full pay B. The Contractor is required to remove and replace the Lot in question C. The Resolution tests are used for pay for that Lot and the Contractor pays for the testing D. The Contractor's QC results are used for pay for that Lot and the Department pays for the testing E. The Contractor pays for the Resolution testing - ANSWER (D.) The Contractor's QC results are used for pay for that Lot and the Department pays for testing (T/F:) A process control sample can be taken anywhere, anytime and is not used in the acceptance decision. - ANSWER True Which Statement(s) is true? A. For fine graded mixes, a type SP-12.5 and a type SP-19.0 can be placed at 2 inches thick

Mostrar más Leer menos
Institución
Asphalt Paving LEVEL 2
Grado
Asphalt Paving LEVEL 2

Vista previa del contenido

Asphalt Paving LEVEL 2 QUESTIONS
AND ANSWERS (VERIFIED 100%)


What is the calculated application rate? (lbs/sq yds) - ANSWER (E.) 164.0 lbs/sq yds

Given: Target Spread Rate: 165 lbs/Sq yds
Given: Truck Weights (tons): 18.2, 19.63, 17.56, 18.78, 19.55
Given: Lane R1, Lift 1
Given: Start Station: 5+98 End Station: 13+60
Given: Lane Width: 13.5 feet

What do you do? (Spread Rate) - ANSWER (A.) Spread Rate is in tolerance - document
and continue

Properly operated, the __ should be moving 80%-90% of the time while paving. -
ANSWER (C.) Augers

Cover Stone for an ARMI layer must be applied at what application rate?
A. 0.6 to 0.8 ft³/yd²
B. 0.26 to 0.33 ft³/yd²
C. 0.34 to 0.57 ft³/yd²
D. 0.02 to 0.08 ft³/yd²
E. Not a specification requirement - ANSWER (B.) 0.26 to 0.33 ft³/yd²

(T/F:) Increasing the layer thickness affects the time available for compaction more
than increasing the mix temperature. - ANSWER True
Using the classroom Project Core Layout Example - Method B from Module 8 - What
are the station numbers for Cores 3-2-1 (576 tons) and 3-2-2 (673 tons)?

,Given Information: Starting Sta. is 10+00, Paving direction is "Up-Station", Spread rate
is 165 lbs/yd², lane width is 12 feet - ANSWER (C.) 52+36, 61+18

Calculate the tack spread rate using the chart from Appendix 1. Given Information:
Type of Tack RS-1h, Mix being placed on milled surface. Complete the calculations
using the given information.

What is the calculated application rate? (gal/yd²)

Ending Sta.: 103+60; Beginning Sta.: 87+42; End Reading: 26/6; Beginning Reading:
22/1; Width of Application: 12 feet; Temp of Tack (Emulsified): 180°F - ANSWER 0.05
gal/yd²

Calculate the tack spread rate using the chart from Appendix 1. Given Information:
Type of Tack RS-1h, Mix being placed on milled surface. Complete the calculations
using the given information.

What do you do?

Ending Sta.: 103+60; Beginning Sta.: 87+42; End Reading: 26/6; Beginning Reading:
22/1; Width of Application: 12 feet; Temp of Tack (Emulsified): 180°F - ANSWER (C.)
Spread rate is in specification - document and continue

Which technique(s) will produce a smoother mat?
A. Emptying the truck in front of the paver
B. Hot stop and start the paver
C. Wait until the 3rd time before acting
D. Increase the frequency of testing until the situation improves
E. Both A and D - ANSWER (B.) Hot stop and start the paver

If two consecutive QC density sublots for a fine graded mix do not meet the

, requirements of the table 334-5 Master Production Range:
A. Make adjustments and continue
B. Terminate the Lot
C. Wait until the 3rd time before acting
D. Increase the frequency of testing until the situation improves
E. Both A and D - ANSWER (B.) Terminate the Lot

(T/F:) When the total quantity of hot mix asphalt for the project, as indicated on the plans
for Type SP and Type FC mixtures only, is less than 2000 tons, the Engineer will accept
the mix on the basis of visual inspection, the Engineer may run acceptance tests to
determine the acceptability of the material. - ANSWER True

If the resolution test results compare favorably with the Contractor's QC test results:
A. The Lot is accepted at full pay
B. The Contractor is required to remove and replace the Lot in question
C. The Resolution tests are used for pay for that Lot and the Contractor pays for the
testing
D. The Contractor's QC results are used for pay for that Lot and the Department pays
for the testing
E. The Contractor pays for the Resolution testing - ANSWER (D.) The Contractor's QC
results are used for pay for that Lot and the Department pays for testing




(T/F:) A process control sample can be taken anywhere, anytime and is not used in the
acceptance decision. - ANSWER True

Which Statement(s) is true?
A. For fine graded mixes, a type SP-12.5 and a type SP-19.0 can be placed at 2
inches thick

Escuela, estudio y materia

Institución
Asphalt Paving LEVEL 2
Grado
Asphalt Paving LEVEL 2

Información del documento

Subido en
14 de mayo de 2025
Número de páginas
21
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

$15.49
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada

Conoce al vendedor
Seller avatar
TopGradeGuru
1.5
(2)

Documento también disponible en un lote

Thumbnail
Package deal
Asphalt paving level 1 & 2.questions and answers verified 100% correct
-
2 2025
$ 28.18 Más información

Conoce al vendedor

Seller avatar
TopGradeGuru Teachme2-tutor
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
11
Miembro desde
1 año
Número de seguidores
0
Documentos
2428
Última venta
1 semana hace
GRADEHUB

We provide access to a wide range of professionally curated exams for students and educators. It offers high-quality, up-to-date assessment materials tailored to various subjects and academic levels. With instant downloads and affordable pricing, it's the go-to resource for exam preparation and academic success.

1.5

2 reseñas

5
0
4
0
3
0
2
1
1
1

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes