According to NRCA roofing manual: steep-slope roof systems, what is recommended nail spacing to fasten battens to the deck? - ANSWER 12" According to OSHA, a toeboard shall be required along the edge of platforms more than ______ above lower levels for a distance sufficient to protect employees below. - ANSWER 10 feet What is the recommenced weight for copper standing seams roofs with widths between seams of excess of 20"? - ANSWER 20 oz

Vista previa del contenido

ROOFING PRACTICE EXAM #2
CORRECT 100%
According to NRCA roofing manual: steep-slope roof systems, what is recommended
nail spacing to fasten battens to the deck? - ANSWER 12"

According to OSHA, a toeboard shall be required along the edge of platforms more than
______ above lower levels for a distance sufficient to protect employees below. -
ANSWER 10 feet

What is the recommenced weight for copper standing seams roofs with widths between
seams of excess of 20"? - ANSWER 20 oz

The NRCA recommends that polyvinyl chloride sheet roofing comply with which ASTM
standard? - ANSWER ASTM D 44434

Spray Polyurethane Foam (SPF) roofing systems require a protective surfacing for all of
the following reasons except: - ANSWER provide walkways for four traffic

Drip Edges shall be mechanically fastened at _____ on center. - ANSWER 12"

Type I asphalt has a minimum ductility of _______ centimeters. - ANSWER 10.0

According to roofing construction and estimating, when flashing a vent pipe on a
concrete tile over an unsealed underlayment system extend the flange of the lead vent
jack under the tile course immediately _______ the pipe. - ANSWER above

All SBS polymer modified asphalt coated base sheets are suitable for use as a -
ANSWER base sheet in the installation of a multiple ply polymer modified membrane
system

The dew point is the temperature at which water vapor will_______. - ANSWER
condense

What is the temperature at which bitumen attains the proper viscosity for built up
membrane application called? - ANSWER equiviscous temperature

If wood battens are not raised to allow for drainage they should be no longer than
________ with approximately 1/2" separation between ends to help drain moisture that
may migrate into the roof system. - ANSWER 4 feet

According to roofing construction and estimating, a roofing felt installed on the outside
of an exterior wall is typically _______times more permeable than a vapor barrier
installed on the inside of an exterior wall. - ANSWER 5

, The NRCA recommends that ______ roofing asphalt be used for slopes greater than
1:12. - ANSWER Type IV

What type of flashing should be installed where the rake of the roof meets a vertical
wall? - ANSWER step flashing

What is the minimum roof slope for metal shingles in hurricanes zones? - ANSWER 4 in
12

According to roofing construction and estimating, what is the typical width of tapered
rigid insulation? - ANSWER 24"

Flat seams roofs that exceed 30 feet in any direction should be divided into sections
with a maximum width of ________ feet to accommodate expansion. - ANSWER 30

What is the quantity of 10" x 8" 3/16" thick pieces of slate per square? Allow a 3"
headlamp and 3-1/2" exposure. - ANSWER 515

What is the recommended end lap for single layer applications of mechanically attached
underlayment in tile roof systems? - ANSWER 4"

According to roofing construction and estimating, what is the minimum softening point
for Type I asphalt? - ANSWER 135 degrees F

According to the architectural sheet metal manual, cleats shall be spaced ______ on
center in an open type valley. - ANSWER 24"

What is the minimum slope lapped, non-soldered metal roofs without applied lap
sealant? - ANSWER 3:12

How far above the upper landing surface should be portable ladder side rails extend? -
ANSWER 3 feet

Manufactured tampered roof insulation is installed for the purpose of - ANSWER
creating a slope to the drain and eaves

According to the NRCA, butyl rubber waterproofing membranes should generally not be
installed when the substrate surface temperature is below: - ANSWER 40 degrees F

A toe board shall be erected along the edge of scaffold platforms more than ______
above lower levels for a distance sufficient to protect employees below. - ANSWER 10
feet

Each wood shake shall be attached with a minimum of _____ fasteners. - ANSWER 2

Información del documento

Subido en
12 de mayo de 2025
Número de páginas
6
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas
$13.49

¿Documento equivocado? Cámbialo gratis Dentro de los 14 días posteriores a la compra y antes de descargarlo, puedes elegir otro documento. Puedes gastar el importe de nuevo.
Escrito por estudiantes que aprobaron
Inmediatamente disponible después del pago
Leer en línea o como PDF

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
Lecchris
3.8
(6)
Vendido
43
Seguidores
15
Artículos
3198
Última venta
3 meses hace



Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes