Commercial Septic System Installer UPDATED ACTUAL Exam Questions and CORRECT Answers All tanks must have: - CORRECT ANSWER - 2 compartments All tanks whether pre-manufactured or constructed on site shall be constructed so that the length is ___________ compared to the width. - CORRECT ANSWER - at least one and one- half (1 1/2) times... "to the width." Septic Tanks may be made of: - CORRECT ANSWER - Concrete, Plastic, fiberglass, or other materials as approved by the departmen

Mostrar más Leer menos
Institución
Septic
Grado
Septic









Ups! No podemos cargar tu documento ahora. Inténtalo de nuevo o contacta con soporte.

Escuela, estudio y materia

Institución
Septic
Grado
Septic

Información del documento

Subido en
21 de marzo de 2025
Número de páginas
8
Escrito en
2024/2025
Tipo
Examen
Contiene
Preguntas y respuestas

Temas

Vista previa del contenido

Commercial Septic System Installer
UPDATED ACTUAL Exam Questions and
CORRECT Answers
All tanks must have: - CORRECT ANSWER - 2 compartments


All tanks whether pre-manufactured or constructed on site shall be constructed so that the length
is ___________ compared to the width. - CORRECT ANSWER - at least one and one- half (1
1/2) times... "to the width."


Septic Tanks may be made of: - CORRECT ANSWER - Concrete, Plastic, fiberglass, or other
materials as approved by the department.


Tank compartment partitions will be located: - CORRECT ANSWER - Not less than two-
thirds or more than three-fourths the Length of the tank from the Inlet end.


Compartment partitions will be constructed so a pass-thru hole or slot equal to or greater than the
diameter of the inlet pipe is positioned below the liquid surface with a
_____________________________. - CORRECT ANSWER - Minimum 25% to a maximum
of 50% of the total liquid depth.


Total liquid depth for larger poured-in-place tanks shall have a maximum of
______________inches - CORRECT ANSWER - 66 inches


True or False: Walls and bottom of poured-in-place septic tanks must be reinforced. - CORRECT
ANSWER - True



How can a Septic tank be reinforced? - CORRECT ANSWER - six inch by 6 inch (6"x6")
No.10 gage welded steel reinforcing wire OR fibrous reinforcing material conforming to ASTM
specifications for such materials.

, How must Tank Lids be Reinforced? - CORRECT ANSWER - using three-eights steel
reinforcing rods (rebar) which shall be spaced twelve inches (12") on center each way extending
a minimum of two and one half (2 1/2") inches and a maximum of three (3") from the outside
edge of the tank lid.


In general, the tank must be able to withstand a uniform live load of ______________________
pounds per square foot in addition to all loads to which an underground tank is normally
subjected. - CORRECT ANSWER - 150


True or False: Walls, bottoms, and lids of poured-in-place septic tanks should have a minimum
thickness of four inches (4"). - CORRECT ANSWER - True


Tank lids shall be constructed in ______________________ pieces and shall have securable,
removable access openings located so that the inlet and outlet tees can be
________________________________. - CORRECT ANSWER - one or two,
readily accessed.


Access opening shall have a minimum of _________________ and maximum of
___________________ free space. - CORRECT ANSWER - Minimum: 15"
Maximum: 24"


Tanks with more than 12 inches of cover must extend access openings to within ______ inches
of the ground surface. - CORRECT ANSWER - 12


All tanks shall be equipped with ________________________________ rated or equivalent tees
at the inlet and outlet ends of the tank. - CORRECT ANSWER - Four inch (4") PVC, ASTM
3034


Tees shall be constructed so they extend into the liquid a minimum of ____________________
and a maximum of __________________ of the liquid depth of the tank. - CORRECT
ANSWER - Min: 25%
Max: 50%

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
MGRADES Stanford University
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
1114
Miembro desde
1 año
Número de seguidores
103
Documentos
68972
Última venta
1 día hace
MGRADES (Stanford Top Brains)

Welcome to MGRADES Exams, practices and Study materials Just think of me as the plug you will refer to your friends Me and my team will always make sure you get the best value from the exams markets. I offer the best study and exam materials for a wide range of courses and units. Make your study sessions more efficient and effective. Dive in and discover all you need to excel in your academic journey!

3.8

177 reseñas

5
75
4
31
3
47
2
9
1
15

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes