FLS Exam Questions and Answers

What are the laparoscope diameters? - Correct Answers -2-10mm

Which degree scope is best for a field in line with port? - Correct Answers -0 degree

How to prevent fogging of scope? - Correct Answers -Use anti fog solution or put scope
in hot water/hot bath

What is the most commonly used light source? - Correct Answers -300 W Xenon lamp

What if there is initial low pressure and high flow rate at entry? - Correct Answers -Leak
in insufflator circuit, make sure everything plugged in correctly

Benefits of monopolar - Correct Answers -Tissue is heated quickly, less thermal
damage/coagulation

Monopolar voltage/frequency - Correct Answers -Low voltage/High frequency
In general, if an ovary is larger than 5 cm or has complex internal US characteristics,
biopsy should be by: - Correct Answers -Oophorectomy

Which needle is safer for use in laparoscopic surgery taper or cutting needle? - Correct
Answers -Taper needle (Smooth)

Needle shape - Correct Answers -Straight, Partially straight, curved

Optimal port position for intracorporeal knot tying - Correct Answers -At least 10 cm
apart
(Surgeons elbows flexed at 90 degrees and adjacent to the surgeon's body)

Needle positioning - Correct Answers -Pick up in the correct orientation
Pass needle back and forth rotating each pass
Fine adjustments by nudging needle and manipulating suture


What does coagulation mode do? - Correct Answers -Repid surface heating with
shallow depth of necrosis, intermittent wave form with higher voltage

,Risk of monopolar - Correct Answers -Current can be diverted through unintentional
pathways, leading to inadvertent tissue injury. Don't use hybrid ports that mix metal with
plastic

Why do you need a grounding pad for monopolar? - Correct Answers -Capacitative
coupling - transfer of energy between two conductors separated by an insulator, transfer
to passive electrode. Can release with tissue injury, but no issue if ground plate is
working as capacitor can't store the charge

Benefits of bipolar - Correct Answers -lower energy, producing less lateral tissue
damage and necrosis. Don't need a grounding pad

Risk of bipolar - Correct Answers -Risk of cutting patient vessels before adequate
sealing, and device doesn't work if there is metal between the jaws

Risk of ultrasonic dissection (harmonic) - Correct Answers -Active blade can injure
something due to high frequency (50mHz)

Discontinue aspirin day of surgery? - Correct Answers -No

How to enter in patient with bowel obstruction? - Correct Answers -Direct visualization

Cut vs Coag - Correct Answers -cut - heat tissue quickly to convert cell water to steam,
lysing the cell
Coag - heat more widely dispersed, less cutting action

smaller tissue area, greater current density and faster heating - Correct Answers -e.g.
Bovie tip

Cut mode - Correct Answers -- Low voltage
- High frequency
- Continuous waveform
- Heats tissue quickly; cell water converts to steam and causes cell to explode

Coagulation mode - Correct Answers -- High voltage
- Low frequency
- Intermittent waveform
- Rapid tissue heating, shallow depth of necrosis
- Non-contact: relies on sparking to tissue

Capacitive coupling - Correct Answers -Transfer current from active electrode through
insulation to passive electrode- electrode to plastic part another LSC instrument
- if constant contact w/ tissue will not store energy and no injury

Direct coupling - Correct Answers -monopolar instrument in direct contact w/ metal
portion of another instrument

, Besides capacitative coupling and direct coupling, other hazards of electrocautery -
Correct Answers -- Current diversion
- Narrow return circuit

Bipolar - Correct Answers -- forceps w/ two twins (one active other return)
- no pt return electrode required)
- no capacitative coupling
- works in "wet" operative field
- less thermal spread compared to monopolar

bipolar seals vessels up to _____ mm in diameter - Correct Answers -7 mm

ultrasonic coagulation shears seals vessels up to ____ mm in diameter - Correct
Answers -5 mm

ultrasonic coagulation shears - Correct Answers -- combo compression and friction
- ONE active blade
- monopolar capacity w/ the one blade
- no capacitative coupling
- high power (MAX): cut
- low power (MIN): coag

How many days prior to surgery does warfarin has to be discontinued? - Correct
Answers -3 days

ASA 2 - Correct Answers -Mild to moderate systemic disease

ASA 3 - Correct Answers -severe systemic disease that limits patient activity, may or
may not be related to reason for surgery

ASA 4 - Correct Answers -Severe systemic disturbances that limit patient and are life-
threatening with or without surgery

ASA 5 - Correct Answers -Little change for survival but surgery last resort (resuscitative
effort)

ASA classes that may not be appropriate for LSC sx - Correct Answers -ASA 4 and 5
- body cannot handle decreased venous return, need for hyperventilation

Length of trocar needed for obese pt - Correct Answers ->100 mm

ABSOLUTE C/I to LSC Sx - Correct Answers -- Inability to tolerate laparotomy
- Hypovolemic shock
- Lack proper surgeon training/experience
- Lack appropriate institutional support
$12.99
Accede al documento completo:

100% de satisfacción garantizada
Inmediatamente disponible después del pago
Tanto en línea como en PDF
No estas atado a nada


Documento también disponible en un lote

Thumbnail
Package deal
FLS Exam Bundle
-
19 2025
$ 219.31 Más información

Conoce al vendedor

Seller avatar
Los indicadores de reputación están sujetos a la cantidad de artículos vendidos por una tarifa y las reseñas que ha recibido por esos documentos. Hay tres niveles: Bronce, Plata y Oro. Cuanto mayor reputación, más podrás confiar en la calidad del trabajo del vendedor.
millyphilip West Virginia University
Ver perfil
Seguir Necesitas iniciar sesión para seguir a otros usuarios o asignaturas
Vendido
2827
Miembro desde
3 año
Número de seguidores
1957
Documentos
41807
Última venta
1 semana hace
white orchid store

EXCELLENCY IN ACCADEMIC MATERIALS ie exams, study guides, testbanks ,case, case study etc

3.7

536 reseñas

5
234
4
85
3
103
2
31
1
83

Recientemente visto por ti

Por qué los estudiantes eligen Stuvia

Creado por compañeros estudiantes, verificado por reseñas

Calidad en la que puedes confiar: escrito por estudiantes que aprobaron y evaluado por otros que han usado estos resúmenes.

¿No estás satisfecho? Elige otro documento

¡No te preocupes! Puedes elegir directamente otro documento que se ajuste mejor a lo que buscas.

Paga como quieras, empieza a estudiar al instante

Sin suscripción, sin compromisos. Paga como estés acostumbrado con tarjeta de crédito y descarga tu documento PDF inmediatamente.

Student with book image

“Comprado, descargado y aprobado. Así de fácil puede ser.”

Alisha Student

Preguntas frecuentes