Quizlet| 757 Questions with 100%
Correct Answers
2009. - ANSWER In Michigan, the residential energy code is based on the _____ IECC,
with certain amendments.
Air leakage. - ANSWER ___________ is the rate of air infiltration in the presence of a
specific pressure differential.
Windows
Attic access hatches
Recessed lights - ANSWER Air leakage is the random movement of air into and out of
________ through cracks and holes.
Table 402.1.1
2009 IECC - ANSWER R-values for insulation and fenestration requirements
by component can be found in
International Energy Conservation Code - ANSWER IECC
U-factor and UA alternatives. - ANSWER The _____________ compliance method
allows for more innovative construction techniques like SIPs or Advanced Framing.
500 sq feet - ANSWER R-30 is permitted in vaulted ceilings, but is limited to
True. - ANSWER Floor insulation must be installed to maintain permanent
and continuous contact with the underside of the subfloor decking. T or F
5, 6 and 7. - ANSWER Michigan falls into climate zones
,False. - ANSWER It is permissible for supply ducts to be run through the framing
cavities of a residential building. T or F
IC rated (Insulation Contact) - ANSWER __________ means an electrical fixture has
been tested and listed as suitable for installation in a cavity where the fixture may come
in contact with insulation.
3%. - ANSWER According to the Dept. of Energy, improved energy codes could
reduce CO2 emissions by
300 sq ft. - ANSWER Attic insulation markers must be installed every _____ square
feet.
True. - ANSWER Buildings that are exempted from the new regulations are those
with very low energy use or ones that are neither heated or cooled. T or F
Yes. - ANSWER A contractor needs to remove a non-load bearing wall, does he need
to pull a permit?
No. - ANSWER A concrete contractor has been hired by an owner to install a driveway
and sidewalks. The lot is flat and the concrete is being place on undisturbed earth with
a prepared base. Does the contractor need to pull a permit?
Yes. - ANSWER A permit has been issued for a building project and there is a code
infraction in the building plans that has been overlooked by the building official. Can the
building official require a correction to a project that they previously overlooked?
Health department. - ANSWER Who issues a well and septic permit?
200 sq. feet.
,IRC R105 - ANSWER Permits are not required for one story detached
accessory structures not exceeding:
The next business day. - ANSWER If work requiring a permit is provided in an
emergency situation, the permit application must be submitted within:
True. - ANSWER If an inspection official is refused entry to a building project, the
official will have recourse to the remedies provided by law which include securing a
warrant from the court and returning with an officer of the law.
No.
IRC R104.8 - ANSWER Can a building official be held liable for any damage occurring
to persons or property as a result of their actions or inaction?
Yes. - ANSWER An owner needs a foundation wall repaired, it has seriously buckled
due to excessive lateral loading from soil pressure. Does the contractor need to pull a
permit?
6 ft.
IRC R105.2 - ANSWER Although contractors should check for restrictive covenants
and local zoning requirements, a permit isn't required from the building official for
installing a fence not over _______ tall.
180 days. - ANSWER If a permit is applied for but not yet approved and the applicant is not
persueing approval after______ days the application will be considered abandoned.
Yes. - ANSWER Can a building official revoke a Certificate of Occupancy?
True. - ANSWER When a project requiring a permit has commenced prior to the issuance
of a permit, the building official is authorized to charge an additional fee. T or F
, 450 - ANSWER Foam plastic is used as insulation. The flame spread index
cannot exceed 75 and the smoke development index cannot exceed
8". - ANSWER Foam plastic used for interior trim shall have a maximum thickness
of 1/2" and a maximum width of
10%. - ANSWER Foam plastic interior trim must not constitute more than __________
of the total wall and ceiling area of any room or space.
1/2". - ANSWER Foam plastic used as insulation in walls must be separated by an
approved thermal barrier. What is the minimum thickness of gypsum wall board being
used as a thermal barrier for spray foam insulated walls?
Framing. - ANSWER Which of these inspections happens last?
Mechanical rough
Plumbing rough
Framing
Electrical rough
Yes. - ANSWER A retaining wall will be five feet tall from the bottom of the footing to
the top of the wall. Do you need to pull a permit?
At the time of inspection. - ANSWER Your building is utilizing engineered products such
as engineered floor joists. When do the installation instructions need to be available at
the work site?
1 3/8" solid wood
1 3/8" honeycomb core
20 minute fire rated
Any of the above - ANSWER A door directly between a garage and a residence shall
never open directly into a sleeping room. The door must also be