Terms in this set (69)
1 kilowatt = _____ Btu/hr 3412
1000 Btu/hr = _____ kilowatt 0.29
All exit doors must open _____. Outward
Stone, steel, concrete, brick
A boiler's foundation must be
substantial, made out of materials
such as _____. (Hint: four example
materials)
A change that affects the pressure-retaining ability of the boiler. Example:
Definition "Alteration" increase in MAWP, decrease in design temperature
Fuel, water, steam, and electricity are removed from any connection of the
Definition "Disconnected boiler" boiler
Steam heating boiler, hot water heating boiler, hot water supply boiler, or
Definition: "Heating Boiler" (Hint: 4 potable water heater that is directly fired with oil, gas, solar energy,
boiler types, 5 fuels types + other electricity, coal, or other solid or liquid fuel.
solid or liquid fuel)
Water boiler designed for operation at pressures exceeding 160 pounds
Definition: "High temperature water
per square inch or temperatures exceeding 250 degrees Fahrenheit.
boiler"
Boiler designed for operation at a pressure not exceeding 160 pounds per
square inch or temperatures not exceeding 250 degrees Fahrenheit at or
Definition: "Hot water heating boiler" near the boiler outlet.
, Boiler designed for operation at pressures not exceeding 160 pounds per
square inch or temperatures not exceeding 250 degrees Fahrenheit at or
near the boiler outlet if the boiler's:
(A) heat input exceeds 200,000 British thermal units per hour;
Definition: "Hot water supply boiler" (B) water temperature exceeds 210 degrees Fahrenheit; or
(C) nominal water-containing capacity exceeds 120 gallons.
Boiler designed for operation at pressures not exceeding 160 pounds per
square inch and water temperatures not exceeding 210 degrees
Fahrenheit if the boiler's:
Definition "Potable water heater" (A) heat input exceeds 200,000 British thermal units per hour; or
(B) nominal water-containing capacity exceeds 120 gallons.
Definition "Preliminary order" Written request to repair/alter boiler or to discontinue boiler usage
Definition "Special inspection" Conducted by executive director, boiler chief, or boiler deputy
Bears stamp of nationally recognized engineering professional society or
jurisdictional stamp (only if jurisdiction has construction standard approved
Definition "Standard Boiler" by executive director)
Pressure vessel in which steam is generated, does not include heat
Definition "Unfired boiler" exchangers, evaporators, or process steam generators
1 year
How long after having your
commission revoked must you wait
before reapplying?
1100 KW
How many kilowatts would require an
electric boiler to have 2 SRVs?
1 kilowatt = _____ Btu/hr 3412
1000 Btu/hr = _____ kilowatt 0.29
All exit doors must open _____. Outward
Stone, steel, concrete, brick
A boiler's foundation must be
substantial, made out of materials
such as _____. (Hint: four example
materials)
A change that affects the pressure-retaining ability of the boiler. Example:
Definition "Alteration" increase in MAWP, decrease in design temperature
Fuel, water, steam, and electricity are removed from any connection of the
Definition "Disconnected boiler" boiler
Steam heating boiler, hot water heating boiler, hot water supply boiler, or
Definition: "Heating Boiler" (Hint: 4 potable water heater that is directly fired with oil, gas, solar energy,
boiler types, 5 fuels types + other electricity, coal, or other solid or liquid fuel.
solid or liquid fuel)
Water boiler designed for operation at pressures exceeding 160 pounds
Definition: "High temperature water
per square inch or temperatures exceeding 250 degrees Fahrenheit.
boiler"
Boiler designed for operation at a pressure not exceeding 160 pounds per
square inch or temperatures not exceeding 250 degrees Fahrenheit at or
Definition: "Hot water heating boiler" near the boiler outlet.
, Boiler designed for operation at pressures not exceeding 160 pounds per
square inch or temperatures not exceeding 250 degrees Fahrenheit at or
near the boiler outlet if the boiler's:
(A) heat input exceeds 200,000 British thermal units per hour;
Definition: "Hot water supply boiler" (B) water temperature exceeds 210 degrees Fahrenheit; or
(C) nominal water-containing capacity exceeds 120 gallons.
Boiler designed for operation at pressures not exceeding 160 pounds per
square inch and water temperatures not exceeding 210 degrees
Fahrenheit if the boiler's:
Definition "Potable water heater" (A) heat input exceeds 200,000 British thermal units per hour; or
(B) nominal water-containing capacity exceeds 120 gallons.
Definition "Preliminary order" Written request to repair/alter boiler or to discontinue boiler usage
Definition "Special inspection" Conducted by executive director, boiler chief, or boiler deputy
Bears stamp of nationally recognized engineering professional society or
jurisdictional stamp (only if jurisdiction has construction standard approved
Definition "Standard Boiler" by executive director)
Pressure vessel in which steam is generated, does not include heat
Definition "Unfired boiler" exchangers, evaporators, or process steam generators
1 year
How long after having your
commission revoked must you wait
before reapplying?
1100 KW
How many kilowatts would require an
electric boiler to have 2 SRVs?