Inhaltsvorschau

Oil burner test Questions with 100%
Correct Answers
What is the largest exposed tank allowed in a building without a permit—
Correct Answer: 660 g


What is tank approval— Correct Answer: UL 80 UL 142


A supply tank shall be securely supported by ridged, non-combustible supports
to prevent settling, sliding or lifting. true or false— Correct Answer: True


What is the largest amount of oil that can be stored with exposed tanks?—
Correct Answer: 1320 g


What is the closest distance a supply tank can be to the burner— Correct
Answer: 5 ft


What is the gauge of a 275 g above ground tank— Correct Answer: 12 gauge


The maximum amount of fuel may be delivered without a permit to store in
effect provided that application has been made in accordance with code.
true or false— Correct Answer: True


Vent pipe for a 500 g tank should be— Correct Answer: 1 1/4"


A supply tank may be supported by any ridge support. true or false— Correct
Answer: False


Stack switch relays can no longer be used in installations or replacement
because— Correct Answer: Their lock-out time is no longer the code
requirement

,An oil safety valve should be used when burner pump is lifting oil. True or false—
Correct Answer: False


On a warm air furnace, the blower comes off and on in short cycles because—
Correct Answer: The fan on/off differential is less than 40°F


What could cause a steam boiler to flood— Correct Answer: Leaky tank less coil


Having to put water in a steam boiler once or twice a week is caused by—
Correct Answer: Weak return line, radiator vents leaking, boiler sprung a leak


Some radiators on a steam system do not heat up because— Correct Answer:
The radiator vents are clogged


On a hot water boiler the pressure is 30psi and the relief valve is open
because— Correct Answer: Leaky tankless coil, bad pressure reducing valve,
perforated tankless bladder


Some forced hot-water radiators are not heating because— Correct Answer:
Vent is clogged, radiators are air bound, radiator valves clogged shut


A cad-cell primary control can lock-out safety because— Correct Answer: Cad-
cell is dirty, Cad-cell is faulty, The cad-cell is not sensing flame


On a no heat call, a cad-cell primary control fired when TT is jumped out
because— Correct Answer: The thermostat or thermostat wired are no good


In-step means— Correct Answer: The primary control start circuit is closed


On a no heat call on a hot water system, the oil burner is off on high-limit, but
the circulator is not running because— Correct Answer: The reverse is open,
circulator motor burnt out, switching relay is faulty

, The burner operates but there is no combustion because— Correct Answer:
There is too much air


On a replacement steam boiler installation, you should pipe full-size risers to the
header. True or false— Correct Answer: False


What is the best way to remove surface oil?— Correct Answer: Skimming


Where should the water like normally be in the sight glass when the boiler is off—
Correct Answer: Center of the sight glass


What is the purpose of the automatic water feed on a steam boiler— Correct
Answer: To maintain a safe minimum water line


What is the purpose of the hartford loop— Correct Answer: To prevent siphoning
of the boiler


What is the normal cut in pressure of a residential steam boiler— Correct Answer:
1/2 psi


What is the purpose of an oil safety valve— Correct Answer: Prevents oil flow in
the event of a line rupture or excessive line inlet pressure


What does the term "approved" mean— Correct Answer: Recognized by a
nationally recognized texting lab


What is a safety control— Correct Answer: Any control used to prevent unsafe
operation of the uncontrolled equipment


What is a draft booster— Correct Answer: Power operated fan installed in the
chimney connector to increase natural draft


What is a "confined space?"— Correct Answer: Any space who's volume is less
than 50 cubic feet per 1000 BTU's of all fuel burning equipment
11,83 €
Vollständigen Zugriff auf das Dokument erhalten:

100% Zufriedenheitsgarantie
Sofort verfügbar nach Zahlung
Sowohl online als auch als PDF
Du bist an nichts gebunden

Lerne den Verkäufer kennen
Seller avatar
StudyRM

Lerne den Verkäufer kennen

Seller avatar
StudyRM University Of California - Los Angeles (UCLA)
Folgen Sie müssen sich einloggen, um Studenten oder Kursen zu folgen.
Verkauft
3
Mitglied seit
4 Jahren
Anzahl der Follower
0
Dokumente
4028
Zuletzt verkauft
1 Jahren vor

0,0

0 rezensionen

5
0
4
0
3
0
2
0
1
0

Kürzlich von dir angesehen.

Warum sich Studierende für Stuvia entscheiden

on Mitstudent*innen erstellt, durch Bewertungen verifiziert

Geschrieben von Student*innen, die bestanden haben und bewertet von anderen, die diese Studiendokumente verwendet haben.

Nicht zufrieden? Wähle ein anderes Dokument

Kein Problem! Du kannst direkt ein anderes Dokument wählen, das besser zu dem passt, was du suchst.

Bezahle wie du möchtest, fange sofort an zu lernen

Kein Abonnement, keine Verpflichtungen. Bezahle wie gewohnt per Kreditkarte oder Sofort und lade dein PDF-Dokument sofort herunter.

Student with book image

“Gekauft, heruntergeladen und bestanden. So einfach kann es sein.”

Alisha Student

Häufig gestellte Fragen