100% Zufriedenheitsgarantie Sofort verfügbar nach Zahlung Sowohl online als auch als PDF Du bist an nichts gebunden 4.2 TrustPilot
logo-home
Prüfung

Fluoroscopy Test - Image Production Exam Questions with Complete Answers

Bewertung
-
Verkauft
-
seiten
7
Klasse
A+
Hochgeladen auf
29-05-2025
geschrieben in
2024/2025

Fluoroscopy Test - Image Production Exam Questions with Complete Answers

Hochschule
Fluoroscopy
Kurs
Fluoroscopy









Ups! Dein Dokument kann gerade nicht geladen werden. Versuch es erneut oder kontaktiere den Support.

Schule, Studium & Fach

Hochschule
Fluoroscopy
Kurs
Fluoroscopy

Dokument Information

Hochgeladen auf
29. mai 2025
Anzahl der Seiten
7
geschrieben in
2024/2025
Typ
Prüfung
Enthält
Fragen & Antworten

Themen

Inhaltsvorschau

Fluoroscopy Test - Image Production
Exam Questions with Complete
Answers

Atomic brightness control (ABC) maintains the brightness of the image by varying
______ - ANSWER-kVp and mA

The time it takes to turn on the digital fluoroscopy x-ray tube and reach the selected
mA and kVp is the ____ time - ANSWER-interrogation

Digital fluoroscopy with a charge-couples device has lower _____ and higher _____
than conventional fluoroscopy - ANSWER-patient dose, light sensitivity

A principal advantage of digital fluoroscopy is the _____ - ANSWER-image
subtraction

Digital fluoroscopic dose rate is lower than that for continuous analog fluoroscopy -
ANSWER-True

The source-to-skin distance limit for stationary fluoroscopic unit is _____ cm -
ANSWER-38

When performing a moblie fluoroscopic procedure, to reduce the radiation exposure
to the patient, the radiographer must use a minimal source-skin distance of _____
cm (_______ inches) - ANSWER-30; 12

How is brightness gain determined - ANSWER-product of minification and flux gain

Image contrast can be improved with ____ techniques - ANSWER-Subtraction

The image captured by FPIR is ________ compared to the ______ image of
traditional fluoroscopy - ANSWER-square, circular

The image intensifier's input phosphor differs from the output phosphor in what way -
ANSWER-is much larger

The time it takes to turn on the digital fluoroscopy x-ray tube and reach the selected
mA and kVp is the _____ time - ANSWER-interrogation

The total dose rate at the table top during fluoroscopy cannot exceed - ANSWER-10
R per minute

What device is required with a direct digital type of fluoroscopy system - ANSWER-
flat detector

, What happens when a multifocus image intensifier tube is operated in the
magnification mode - ANSWER-the electron focal point is closer to the input
phosphor

When using a 25/17/12 image intensifier tube, which of the following is true: -
ANSWER-the field of view is largest in the 25 cm mode

Which of the following describes the fluoroscopic system designed to maintain a
constant image brightness - ANSWER-automatic brightness control

Which of the following modes of a trifield image intensifier will result in the highest
patient dose - ANSWER-its 12 inch mode

If using a dynamic flat panel detector in fluoroscopy, the image intensifier is no
longer needed - ANSWER-True

The FPIR signal when used in DF is already digital - ANSWER-True

What is the minification gain for an image intensification tube with an input screen
diameter of 5 inches and an output diameter of 1 inch - ANSWER-25

What is the total brightness gain for an image intensification tube with a minification
gain of 25 and a fluc gain of 50 - ANSWER-1250

An image intensifier tube is identified by the diameter of its - ANSWER-input
phosphor

Brightness gain is typically in the range of _____. - ANSWER-5000-30000

During fluoroscopic image intensification, the primary x-ray beam exits the patient
and strikes the ____ of the image intensifier. - ANSWER-input screen

electrons hit the ___ after exiting the anode - ANSWER-output phosphor

Electrostatic lenses are actually _____ - ANSWER-charged electrodes

Electrostatic lenses are used to accelerate and focus - ANSWER-electrons

The image intensifier improved fluoroscopy by increasing image - ANSWER-
brightness

The input screen absorbs _____ and emits _____ - ANSWER-xray photons, light
photons

The kinetic energy of photoelectrons in the image intensifier is greatly increased by
the - ANSWER-potential difference across the tube

The number of light photons emitted within the image intensifier is ______ to the
amount of xray photons exiting the patient - ANSWER-directly proportional
16,23 €
Vollständigen Zugriff auf das Dokument erhalten:

100% Zufriedenheitsgarantie
Sofort verfügbar nach Zahlung
Sowohl online als auch als PDF
Du bist an nichts gebunden


Ebenfalls erhältlich im paket-deal

Lerne den Verkäufer kennen

Seller avatar
Bewertungen des Ansehens basieren auf der Anzahl der Dokumente, die ein Verkäufer gegen eine Gebühr verkauft hat, und den Bewertungen, die er für diese Dokumente erhalten hat. Es gibt drei Stufen: Bronze, Silber und Gold. Je besser das Ansehen eines Verkäufers ist, desto mehr kannst du dich auf die Qualität der Arbeiten verlassen.
lectknancy Boston University
Folgen Sie müssen sich einloggen, um Studenten oder Kursen zu folgen.
Verkauft
284
Mitglied seit
2 Jahren
Anzahl der Follower
28
Dokumente
26008
Zuletzt verkauft
1 Jahren vor

3,6

57 rezensionen

5
23
4
10
3
11
2
3
1
10

Kürzlich von dir angesehen.

Warum sich Studierende für Stuvia entscheiden

on Mitstudent*innen erstellt, durch Bewertungen verifiziert

Geschrieben von Student*innen, die bestanden haben und bewertet von anderen, die diese Studiendokumente verwendet haben.

Nicht zufrieden? Wähle ein anderes Dokument

Kein Problem! Du kannst direkt ein anderes Dokument wählen, das besser zu dem passt, was du suchst.

Bezahle wie du möchtest, fange sofort an zu lernen

Kein Abonnement, keine Verpflichtungen. Bezahle wie gewohnt per Kreditkarte oder Sofort und lade dein PDF-Dokument sofort herunter.

Student with book image

“Gekauft, heruntergeladen und bestanden. So einfach kann es sein.”

Alisha Student

Häufig gestellte Fragen