A condensing unit should be mounted on a slab that is level to: A: Allow any accumulated water to evenly run out of the cabinet B: Increase airflow through the fin area C: Prevent the unit from tipping over D: Make certain any top discharge air blows straight up - Answer: A A simple time-activated switch is an example of a control that does not use: A: Feedback B: Electronics C: Calibration D: Manual adjustment - Answer: A Which of the following systems would typically require a blower with a 2000 cfm output? A: 2-ton ac system B: 3-ton ac system C: 5-ton ac system D: 7.5-ton ac system - Answer: C A typical induced-draft furnace uses a blower-off delay in the cooling mode to: a. Increase the efficiency of the system b. Air wash the coil on shutdown c. Minimize dehumidification at the coil d. Prevent blowing moisture off the coil on shut off - Answer: A Which of the following would a technician use to check the operating sequence of an air conditioning system? A: Schematic B: Warranty Information C: Furnace manual D: All of the above - Answer: A Rafters in typical residential construction are how far apart? a. 12 inches b. 14 inches c. 16 inches d. 18 inches - Answer: C Which of the following components is energized first after an intermittent ignition gas furnace calls for heat? A: Induced draft motor B: Pilot valve C: Blower motor D: Gas valve - Answer: A To have a system automatically switch to heating or cooling as the load changes, the thermostat: A: System switch should be in auto B: System switch should be in off C: System switch should be on D: Fan switch should be in auto - Answer: A A typical heat pump uses a high-pressure control to shut off the compressor if the condensing pressure becomes excessive. The control uses a switch that makes the compressor contact on a pressure: A: Rise at the compressor discharge B: Fall at the compressor discharge

Mehr anzeigen Weniger lesen
Hochschule
Nate Commercial
Kurs
Nate commercial











Ups! Dein Dokument kann gerade nicht geladen werden. Versuch es erneut oder kontaktiere den Support.

Schule, Studium & Fach

Hochschule
Nate commercial
Kurs
Nate commercial

Dokument Information

Hochgeladen auf
14. august 2024
Anzahl der Seiten
36
geschrieben in
2024/2025
Typ
Prüfung
Enthält
Fragen & Antworten

Themen

Inhaltsvorschau

NATE Final Exam
#2 Questions and
Complete Solutions
Graded A+
Denning [Date] [Course title]

,A condensing unit should be mounted on a slab that is level to:



A: Allow any accumulated water to evenly run out of the cabinet



B: Increase airflow through the fin area



C: Prevent the unit from tipping over



D: Make certain any top discharge air blows straight up - Answer: A



A simple time-activated switch is an example of a control that does not use:



A: Feedback



B: Electronics



C: Calibration



D: Manual adjustment - Answer: A



Which of the following systems would typically require a blower with a 2000 cfm output?



A: 2-ton ac system



B: 3-ton ac system



C: 5-ton ac system



D: 7.5-ton ac system - Answer: C

,A typical induced-draft furnace uses a blower-off delay in the cooling mode to:



a. Increase the efficiency of the system

b. Air wash the coil on shutdown

c. Minimize dehumidification at the coil

d. Prevent blowing moisture off the coil on shut off - Answer: A



Which of the following would a technician use to check the operating sequence of an air conditioning
system?



A: Schematic



B: Warranty Information



C: Furnace manual



D: All of the above - Answer: A



Rafters in typical residential construction are how far apart?



a. 12 inches

b. 14 inches

c. 16 inches

d. 18 inches - Answer: C



Which of the following components is energized first after an intermittent ignition gas furnace calls for
heat?

, A: Induced draft motor



B: Pilot valve



C: Blower motor



D: Gas valve - Answer: A



To have a system automatically switch to heating or cooling as the load changes, the thermostat:



A: System switch should be in auto



B: System switch should be in off



C: System switch should be on



D: Fan switch should be in auto - Answer: A



A typical heat pump uses a high-pressure control to shut off the compressor if the condensing pressure
becomes excessive. The control uses a switch that makes the compressor contact on a pressure:



A: Rise at the compressor discharge



B: Fall at the compressor discharge



C: Difference between the high and low side



D: Combination of the high and low side - Answer: B
12,36 €
Vollständigen Zugriff auf das Dokument erhalten:

100% Zufriedenheitsgarantie
Sofort verfügbar nach Zahlung
Sowohl online als auch als PDF
Du bist an nichts gebunden


Ebenfalls erhältlich im paket-deal

Lerne den Verkäufer kennen

Seller avatar
Bewertungen des Ansehens basieren auf der Anzahl der Dokumente, die ein Verkäufer gegen eine Gebühr verkauft hat, und den Bewertungen, die er für diese Dokumente erhalten hat. Es gibt drei Stufen: Bronze, Silber und Gold. Je besser das Ansehen eines Verkäufers ist, desto mehr kannst du dich auf die Qualität der Arbeiten verlassen.
YourExamplug Grand Canyon University
Folgen Sie müssen sich einloggen, um Studenten oder Kursen zu folgen.
Verkauft
173
Mitglied seit
1 Jahren
Anzahl der Follower
26
Dokumente
14429
Zuletzt verkauft
2 Jahren vor
Your Exm Plug

Assignments, Case Studies, Research, Essay writing service, Questions and Answers, Discussions etc. for students who want to see results twice as fast. I have done papers of various topics and complexities. I am punctual and always submit work on-deadline. I write engaging and informative content on all subjects. Send me your research papers, case studies, psychology papers, etc, and I’ll do them to the best of my abilities. Writing is my passion when it comes to academic work. I’ve got a good sense of structure and enjoy finding interesting ways to deliver information in any given paper. I love impressing clients with my work, and I am very punctual about deadlines. Send me your assignment and I’ll take it to the next level. I strive for my content to be of the highest quality. Your wishes come first— send me your requirements and I’ll make a piece of work with fresh ideas, consistent structure, and following the academic formatting rules. For every student you refer to me with an order that is completed and paid transparently, I will do one assignment for you, free of charge!!!!!!!!!!!!

Mehr lesen Weniger lesen
4,3

67 rezensionen

5
38
4
16
3
7
2
4
1
2

Kürzlich von dir angesehen.

Warum sich Studierende für Stuvia entscheiden

on Mitstudent*innen erstellt, durch Bewertungen verifiziert

Geschrieben von Student*innen, die bestanden haben und bewertet von anderen, die diese Studiendokumente verwendet haben.

Nicht zufrieden? Wähle ein anderes Dokument

Kein Problem! Du kannst direkt ein anderes Dokument wählen, das besser zu dem passt, was du suchst.

Bezahle wie du möchtest, fange sofort an zu lernen

Kein Abonnement, keine Verpflichtungen. Bezahle wie gewohnt per Kreditkarte oder Sofort und lade dein PDF-Dokument sofort herunter.

Student with book image

“Gekauft, heruntergeladen und bestanden. So einfach kann es sein.”

Alisha Student

Häufig gestellte Fragen