100% Zufriedenheitsgarantie Sofort verfügbar nach Zahlung Sowohl online als auch als PDF Du bist an nichts gebunden 4.2 TrustPilot
logo-home
Prüfung

EPA 608 Guaranteed Success

Bewertung
-
Verkauft
-
seiten
9
Klasse
A+
Hochgeladen auf
06-08-2024
geschrieben in
2024/2025

EPA 608 Guaranteed Success 1. Definition of Reclaiming: - To process refrigerant to a level equal to new (virgin) product specifications as determined by chemical analysis defines: ️ Reclaiming. 2. Disposable Cylinder Disposal Method: - The proper disposal method for disposable cylinders is to ️ recover any remaining refrigerant and then render the cylinder useless, then recycle the metal. 3. Definition of Recycling: - Clean refrigerant for reuse by separating the oil from the refrigerant by passing it through one or more filter driers is the definition of: ️ Recycle. 4. GWP of R-1234ze: - The Global Warming Potential (GWP) of R-1234ze is ️ 0. 5. Hydrostatic Testing Frequency: - Reusable refrigerant containers under high pressure must be hydrostatically tested how often? ️ Every 5 years. 6. Venting Off Refrigerant Vapor: - When filling a charging cylinder with a regulated refrigerant, the refrigerant vapor that is vented off the top must be ️ recovered. 7. Example of Non-condensable: - An example of a non-condensable is ️ air. 8. Vacuum System Safety: - When a system is in deep vacuum, never ️ energize the compressor. 9. HC Refrigerant for Small Appliances: - The HC refrigerant allowed for use in new domestic small appliances is ️ R-600a. 10. Leak Rate Repair Requirement: - Leaks must be repaired on industrial process and refrigeration units with a 50-pound charge or greater when the annualized leak rate reaches ️ 30% or more. 11. Refrigerant Trace Gas Release: - What can be done with a refrigerant trace gas and nitrogen mixture after a system leak is found? ️ Release into atmosphere. 12. Classification of Common Refrigerants: - Refrigerants CFC R-12, HCFC R-22, and HFC 134a are all classified as ️ A1. 13. Evacuation Level for R-410A: - When using a recovery unit on a system containing 100 lbs of R-410A, it must be evacuated to: ️ 0" Hg. 14. Dehydration Level: - When dehydrating a system, it should be evacuated to a level of ️ 500 microns. 15. Condensing and Refrigerant Recovery: - Refrigerant should be recovered from the condenser outlet if the condenser is ️ below the receiver. 16. Action for Non-Repairable Leaking Appliance: - If a leaking appliance with a regulated refrigerant is not going to be repaired, it must be ️ retrofitted or retired within 12 months. 17. Recovery Level for Medium Pressure System: - When recovering a medium pressure system with more than 200 lbs of refrigerant, recover to a level of: ️ 15" Hg. 18. Standard for Machine Room Safety: - The standard for machine room safety is ️ ASHRAE 15. 19. Safety Classification of HCFC-123: - The safety classification of HCFC-123 is ️ B1. 20. EPA Evacuation Level for Low Pressure Systems: - The EPA required evacuation level for recovery or recycling equipment used on low-pressure systems is ️ 25 mm of Hg absolute. 21. Equipment for Type III Certification: - What type of equipment can be worked on with Type III certification? ️ Low pressure. 22. Safety Classification of R-134A: - The safety classification of R-134A under ASHRAE Standard 34 is ️ A1. 23. Rupture Disk Burst Pressure: - The rupture disk on a low-pressure chiller has a burst pressure of ️ 15 psig. 24. Maximum Pressure for Leak Detection: - When pressurizing a low-pressure system for leak detection purposes, do not exceed ️ 10 psig. 25. Oil Used in HFC and HFO Systems: - The oil used in HFC and HFO HVACR systems is ️ Esters.

Mehr anzeigen Weniger lesen
Hochschule
Kurs









Ups! Dein Dokument kann gerade nicht geladen werden. Versuch es erneut oder kontaktiere den Support.

Schule, Studium & Fach

Hochschule
Studium
Kurs

Dokument Information

Hochgeladen auf
6. august 2024
Anzahl der Seiten
9
geschrieben in
2024/2025
Typ
Prüfung
Enthält
Fragen & Antworten

Themen

Inhaltsvorschau

EPA 608 Guaranteed Success


1. Definition of Reclaiming:

- To process refrigerant to a level equal to new (virgin) product specifications as determined by
chemical analysis defines: ✔️ Reclaiming.



2. Disposable Cylinder Disposal Method:

- The proper disposal method for disposable cylinders is to ✔️ recover any remaining refrigerant and
then render the cylinder useless, then recycle the metal.



3. Definition of Recycling:

- Clean refrigerant for reuse by separating the oil from the refrigerant by passing it through one or
more filter driers is the definition of: ✔️ Recycle.



4. GWP of R-1234ze:

- The Global Warming Potential (GWP) of R-1234ze is ✔️ 0.



5. Hydrostatic Testing Frequency:

- Reusable refrigerant containers under high pressure must be hydrostatically tested how often? ✔️
Every 5 years.



6. Venting Off Refrigerant Vapor:

- When filling a charging cylinder with a regulated refrigerant, the refrigerant vapor that is vented off
the top must be ✔️ recovered.



7. Example of Non-condensable:

- An example of a non-condensable is ✔️ air.



8. Vacuum System Safety:

- When a system is in deep vacuum, never ✔️ energize the compressor.

, 9. HC Refrigerant for Small Appliances:

- The HC refrigerant allowed for use in new domestic small appliances is ✔️ R-600a.



10. Leak Rate Repair Requirement:

- Leaks must be repaired on industrial process and refrigeration units with a 50-pound charge or
greater when the annualized leak rate reaches ✔️ 30% or more.



11. Refrigerant Trace Gas Release:

- What can be done with a refrigerant trace gas and nitrogen mixture after a system leak is found?
✔️ Release into atmosphere.



12. Classification of Common Refrigerants:

- Refrigerants CFC R-12, HCFC R-22, and HFC 134a are all classified as ✔️ A1.



13. Evacuation Level for R-410A:

- When using a recovery unit on a system containing 100 lbs of R-410A, it must be evacuated to: ✔️
0" Hg.



14. Dehydration Level:

- When dehydrating a system, it should be evacuated to a level of ✔️ 500 microns.



15. Condensing and Refrigerant Recovery:

- Refrigerant should be recovered from the condenser outlet if the condenser is ✔️ below the
receiver.



16. Action for Non-Repairable Leaking Appliance:

- If a leaking appliance with a regulated refrigerant is not going to be repaired, it must be ✔️
retrofitted or retired within 12 months.
9,63 €
Vollständigen Zugriff auf das Dokument erhalten:

100% Zufriedenheitsgarantie
Sofort verfügbar nach Zahlung
Sowohl online als auch als PDF
Du bist an nichts gebunden


Ebenfalls erhältlich im paket-deal

Lerne den Verkäufer kennen

Seller avatar
Bewertungen des Ansehens basieren auf der Anzahl der Dokumente, die ein Verkäufer gegen eine Gebühr verkauft hat, und den Bewertungen, die er für diese Dokumente erhalten hat. Es gibt drei Stufen: Bronze, Silber und Gold. Je besser das Ansehen eines Verkäufers ist, desto mehr kannst du dich auf die Qualität der Arbeiten verlassen.
bestscores1 Kent State University
Folgen Sie müssen sich einloggen, um Studenten oder Kursen zu folgen.
Verkauft
12
Mitglied seit
1 Jahren
Anzahl der Follower
0
Dokumente
1369
Zuletzt verkauft
3 Jahren vor
ReadEase

Welcome to ReadEase, your ultimate resource for exam preparation. At ReadEase, we specialize in providing comprehensive study materials and resources to help you excel in your exams. Whether you're preparing for standardized tests, professional certifications, or academic assessments, our finely curated collection covers a wide range of subjects and levels. From practice tests and study guides to expert tips and strategies, we're here to support your journey to success. ReadEase is committed to availing high-quality educational content, helping you thrive and achieve your academic and professional goals. Have any questions? We're just a message away.

Mehr lesen Weniger lesen
4,3

4 rezensionen

5
2
4
1
3
1
2
0
1
0

Kürzlich von dir angesehen.

Warum sich Studierende für Stuvia entscheiden

on Mitstudent*innen erstellt, durch Bewertungen verifiziert

Geschrieben von Student*innen, die bestanden haben und bewertet von anderen, die diese Studiendokumente verwendet haben.

Nicht zufrieden? Wähle ein anderes Dokument

Kein Problem! Du kannst direkt ein anderes Dokument wählen, das besser zu dem passt, was du suchst.

Bezahle wie du möchtest, fange sofort an zu lernen

Kein Abonnement, keine Verpflichtungen. Bezahle wie gewohnt per Kreditkarte oder Sofort und lade dein PDF-Dokument sofort herunter.

Student with book image

“Gekauft, heruntergeladen und bestanden. So einfach kann es sein.”

Alisha Student

Häufig gestellte Fragen