An aquastat stops and starts a burner by sensing the ___ temperature. - ANSWERSBOILER WATER The number of blowdowns required for a boiler can be determined by ___. - ANSWERStesting the boiler water Oxygen in a boiler causes ___. - ANSWERSPITTING Impurities on the water surface in a steam and water drum are best removed by ___ blowdown. - ANSWERSSURFACE A modulating pressure control on a steam boiler is used to control the ___. - ANSWERShigh and low fire ranges A(n) ___ is a boiler water treatment accessory that heats feedwater to the temperature of saturated steam within the pressure vessel. - ANSWERSdeaerator When a boiler reaches a pressure above the safety valve setting, the operator must first ___. - ANSWERSsecure the boiler The first thing a boiler operator should do when taking over a shift is check the ___ for each boiler that is operating. - ANSWERSwater level in the gauge glass A boiler generating 20,000 lb/hr of steam must be supplied with at least ___ of feedwater. - ANSWERS20,000 lb/hr When starting a boiler and bringing it on-line in battery with another boiler, the main steam stop valve should be opened ___ than the header pressure. - ANSWERSslowly when the boiler pressure is slightly less As a precaution when giving a boiler a bottom blowdown, boiler operators should ___. - ANSWERSalways check the boiler water level On a boiler under steam pressure, if the top gauge glass fitting from the water column is blocked, then the water level in the gauge glass will ___ if the water level in the boiler remains constant. - ANSWERSINCREASE When a boiler is being cleaned, repaired, or inspected, the main steam stop valve must be ___. - ANSWERStightly closed, locked, and tagged out

Mehr anzeigen Weniger lesen
Hochschule
Boilers License Practice
Kurs
Boilers License Practice








Ups! Dein Dokument kann gerade nicht geladen werden. Versuch es erneut oder kontaktiere den Support.

Schule, Studium & Fach

Hochschule
Boilers License Practice
Kurs
Boilers License Practice

Dokument Information

Hochgeladen auf
13. januar 2026
Anzahl der Seiten
4
geschrieben in
2025/2026
Typ
Prüfung
Enthält
Fragen & Antworten

Themen

Inhaltsvorschau

Boilers License Practice Test #1
Questions with Correct Answers
An aquastat stops and starts a burner by sensing the ___ temperature. -
ANSWERSBOILER WATER

The number of blowdowns required for a boiler can be determined by ___. -
ANSWERStesting the boiler water

Oxygen in a boiler causes ___. - ANSWERSPITTING

Impurities on the water surface in a steam and water drum are best removed by ___
blowdown. - ANSWERSSURFACE

A modulating pressure control on a steam boiler is used to control the ___. -
ANSWERShigh and low fire ranges

A(n) ___ is a boiler water treatment accessory that heats feedwater to the temperature
of saturated steam within the pressure vessel. - ANSWERSdeaerator

When a boiler reaches a pressure above the safety valve setting, the operator must first
___. - ANSWERSsecure the boiler

The first thing a boiler operator should do when taking over a shift is check the ___ for
each boiler that is operating. - ANSWERSwater level in the gauge glass

A boiler generating 20,000 lb/hr of steam must be supplied with at least ___ of
feedwater. - ANSWERS20,000 lb/hr

When starting a boiler and bringing it on-line in battery with another boiler, the main
steam stop valve should be opened ___ than the header pressure. - ANSWERSslowly
when the boiler pressure is slightly less

As a precaution when giving a boiler a bottom blowdown, boiler operators should ___. -
ANSWERSalways check the boiler water level

On a boiler under steam pressure, if the top gauge glass fitting from the water column is
blocked, then the water level in the gauge glass will ___ if the water level in the boiler
remains constant. - ANSWERSINCREASE

When a boiler is being cleaned, repaired, or inspected, the main steam stop valve must
be ___. - ANSWERStightly closed, locked, and tagged out

Lerne den Verkäufer kennen

Seller avatar
Bewertungen des Ansehens basieren auf der Anzahl der Dokumente, die ein Verkäufer gegen eine Gebühr verkauft hat, und den Bewertungen, die er für diese Dokumente erhalten hat. Es gibt drei Stufen: Bronze, Silber und Gold. Je besser das Ansehen eines Verkäufers ist, desto mehr kannst du dich auf die Qualität der Arbeiten verlassen.
Bestgrades2 West Virginia University
Folgen Sie müssen sich einloggen, um Studenten oder Kursen zu folgen.
Verkauft
23
Mitglied seit
1 Jahren
Anzahl der Follower
0
Dokumente
4142
Zuletzt verkauft
3 Jahren vor

4,0

3 rezensionen

5
1
4
1
3
1
2
0
1
0

Kürzlich von dir angesehen.

Warum sich Studierende für Stuvia entscheiden

on Mitstudent*innen erstellt, durch Bewertungen verifiziert

Geschrieben von Student*innen, die bestanden haben und bewertet von anderen, die diese Studiendokumente verwendet haben.

Nicht zufrieden? Wähle ein anderes Dokument

Kein Problem! Du kannst direkt ein anderes Dokument wählen, das besser zu dem passt, was du suchst.

Bezahle wie du möchtest, fange sofort an zu lernen

Kein Abonnement, keine Verpflichtungen. Bezahle wie gewohnt per Kreditkarte oder Sofort und lade dein PDF-Dokument sofort herunter.

Student with book image

“Gekauft, heruntergeladen und bestanden. So einfach kann es sein.”

Alisha Student

Häufig gestellte Fragen