1. What is the minimum required combustion air opening size for a furnace located

in a confined space with a total input rating of 150,000 BTU/h, using indoor air?

A) 50 sq in

B) 100 sq in

C) 150 sq in

D) 200 sq in

Answer: C – 150 sq in

Explanation: According to the International Mechanical Code (IMC) and Minnesota

amendments, a confined space must have two combustion air openings, each sized at 1

sq in per 1,000 BTU/h of total input. For 150,000 BTU/h, each opening must be 150 sq in....