Lote
PACKAGE DEAL::: HEARING AID DISPENSER (ILE EXAMS) 2025/2026 QUESTIONS AND 100% CORRECT ANSWERS
-
---6agosto 2025
- PACKAGE DEAL::: HEARING AID DISPENSER (ILE EXAMS) 2025/2026 QUESTIONS AND 100% CORRECT ANSWERS
-
$29.77 Más información
mercylynneh
-
Examen
ILE EXAM HEARING AIDS ACTUAL 2025/2026 QUESTIONS AND 100% CORRECT ANSWERS
-
--7agosto 20252025/2026A+Disponible en un paquete
- ILE EXAM HEARING AIDS ACTUAL 
2025/2026 QUESTIONS AND 100% 
CORRECT ANSWERS 
Hand Cupped Behind Ear - Answer --first Hearing Aid 
-increased sound by 5-8db 
-included horns,trumpets, speaking tubes 
1892 - Answer --carbon amplifiers patent by Alexander Bell 
-marketed until 1930;first patent for a telephone type 
hearing instrument 
1920 - Answer -large vacuum tubes; not portable 
1938 - Answer -miniature vacuum tube ;crystal receivers 
1930 - Answer -diameter reduced 
1940 - Answer -bone condu...
-
$12.49 Más información
mercylynneh
-
Examen
ILE EXAM SEPT 17TH ACTUAL 2025/2026 QUESTIONS AND 100% CORRECT ANSWERS
-
--16agosto 20252025/2026A+Disponible en un paquete
- ILE EXAM SEPT 17TH ACTUAL 
2025/2026 QUESTIONS AND 100% 
CORRECT ANSWERS 
A PT hearing evaluation reveals moderate symmetrical loss without airbone gaps. WRS 60% in AS, 72% AD and 44% AU. The PT has never worn 
amplification. The case history reveals arthritis, diabetes, and macular 
degeneration. what is a possible contraindication for fitting both ears? 
A. bilateral recruitment 
B. poor binaural QuickSIN score 
C. poor bilateral fusion 
D. Bilateral conductive components - Answer -C. poor bil...
-
$12.49 Más información
mercylynneh
-
Examen
ILE EXAM PREP ACTUAL 2025/2026 QUESTIONS AND 100% CORRECT ANSWERS
-
--26agosto 20252025/2026A+Disponible en un paquete
- ILE EXAM PREP ACTUAL 
2025/2026 QUESTIONS AND 100% 
CORRECT ANSWERS 
The PT brings in their 4 year old high end digital signal processing 
hearing instrument because its not working at all. It is out of warranty. 
All of the source of the problem has not been found and the hearing 
instrument is still not working. At this point the hearing instrument 
specialist has no choice but to _______ 
A. recommend that they purchase a new set 
B. send it to an all-make repair facility 
C. send it to the m...
-
$12.49 Más información
mercylynneh
-
Examen
COSTCO ILE 3 EXAM ACTUAL 2025/2026 QUESTIONS AND 100% CORRECT ANSWERS
-
--19agosto 20252025/2026A+Disponible en un paquete
- COSTCO ILE 3 EXAM ACTUAL 
2025/2026 QUESTIONS AND 100% 
CORRECT ANSWERS 
why are vents used in ear molds and custom Hearing Instruments? 
a. To enhance low frequencies 
B. To decrease high frequencies 
C. To decrease low frequencies 
D. To enhance high frequencies - Answer -C 
when a patient can hear voices further away rather than close what 
should the hearing healthcare provider consider adjusting? 
A. increase loud sounds so that compression decreases. 
B. increase soft sounds so that compre...
-
$12.49 Más información
mercylynneh
-
Examen
PRACTICAL EXAM-HEARING AID DISPENSER ACTUAL 2025/2026 QUESTIONS AND 100% CORRECT ANSWERS
-
--16agosto 20252025/2026A+Disponible en un paquete
- PRACTICAL EXAM-HEARING AID 
DISPENSER ACTUAL 2025/2026 
QUESTIONS AND 100% CORRECT 
ANSWERS 
List at least 3 advantages of Binaural Hearing over a monaural fitting: - 
Answer -Better sound localization, better hearing in background noise, 
the ability to focus one sound over another, sounds appear louder, 
better peach comprehension. 
Causes of S/N hearing loss include: - Answer -1. Noise induced HL 
2. Noise trauma 
3. Presbycusis 
4. Congenital HL 
5. Syndromic HL (Waardenburg, Treacher Collin...
-
$12.49 Más información
mercylynneh
-
Examen
HEARING AID DISPENSER EXAM ACTUAL 2025/2026 QUESTIONS AND 100% CORRECT ANSWERS
-
--33agosto 20252025/2026A+Disponible en un paquete
- HEARING AID DISPENSER EXAM 
ACTUAL 2025/2026 QUESTIONS 
AND 100% CORRECT ANSWERS 
Typanometry - Answer -What identifies a measure of of compliance of 
the TM (ear drum)? 
+200 H2O to -200 H2O - Answer -Typanograms probe tip measures 
from...... 
Type A Tympanogram - Answer -A (normal) Intact TM(ear drum). 
Requires the presents of air in the middle ear, an intact ossicles, an 
normal Eustachian tube. 
Type As Typanogram(shallow). - Answer -Transfer of energy is stiffened. 
Stiffened movement of ...
-
$12.49 Más información
mercylynneh
-
Examen
ILE EXAM HEARING AIDS ACTUAL 2025/2026 QUESTIONS AND 100% CORRECT ANSWERS
-
--7junio 20252024/2025A+Disponible en un paquete
- ILE EXAM HEARING AIDS ACTUAL 
2025/2026 QUESTIONS AND 100% 
CORRECT ANSWERS 
Hand Cupped Behind Ear - Answer --first Hearing Aid 
-increased sound by 5-8db 
-included horns,trumpets, speaking tubes 
1892 - Answer --carbon amplifiers patent by Alexander Bell 
-marketed until 1930;first patent for a telephone type 
hearing instrument 
1920 - Answer -large vacuum tubes; not portable 
1938 - Answer -miniature vacuum tube ;crystal receivers 
1930 - Answer -diameter reduced 
1940 - Answer -bone condu...
-
$12.49 Más información
AdelineJean
-
Examen
ILE EXAM SEPT 17TH ACTUAL 2025/2026 QUESTIONS AND 100% CORRECT ANSWERS
-
--16junio 20252024/2025A+Disponible en un paquete
- ILE EXAM SEPT 17TH ACTUAL 
2025/2026 QUESTIONS AND 100% 
CORRECT ANSWERS 
A PT hearing evaluation reveals moderate symmetrical loss without airbone gaps. WRS 60% in AS, 72% AD and 44% AU. The PT has never worn 
amplification. The case history reveals arthritis, diabetes, and macular 
degeneration. what is a possible contraindication for fitting both ears? 
A. bilateral recruitment 
B. poor binaural QuickSIN score 
C. poor bilateral fusion 
D. Bilateral conductive components - Answer -C. poor bil...
-
$12.49 Más información
AdelineJean