Residential Electrical Services Questions With Complete Solutions. 
Which of that following locations at dwelling units require GFCI protection? 
Receptacles within gaarages 
Which type of cable with a corrugated sheath has a maximum bend raduis of 7 times the cable diameter? 
Type MC 
Which of the following circuits require a minimum of 20A of overcurrent protection? 
Residential small appliance branch circuits 
According to the NEC, which of the following is required for the small appliance lo...
- Exam (elaborations)
- • 3 pages's •
-
Residential Electrical Services•Residential Electrical Services
Preview 1 out of 3 pages
Residential Electrical Services Questions With Complete Solutions. 
Which of that following locations at dwelling units require GFCI protection? 
Receptacles within gaarages 
Which type of cable with a corrugated sheath has a maximum bend raduis of 7 times the cable diameter? 
Type MC 
Which of the following circuits require a minimum of 20A of overcurrent protection? 
Residential small appliance branch circuits 
According to the NEC, which of the following is required for the small appliance lo...
Residential Electrical Services Quizzes With 100% Correct Answers. 
An example of a location in a dwelling where a receptacle must have GFCI protection is a 
garage 
A type of cable with a corrugated sheath that has a maximum bend radius of 7 times the cable diameter is _____. 
Type MC 
a residence with 1,000 square feet of living space has a general lighting load of _____. 
3,000 VA 
According to the NEC®, the small appliance loads in each kitchen area of a dwelling must be served by at least ...
- Exam (elaborations)
- • 3 pages's •
-
Residential Electrical Services•Residential Electrical Services
Preview 1 out of 3 pages
Residential Electrical Services Quizzes With 100% Correct Answers. 
An example of a location in a dwelling where a receptacle must have GFCI protection is a 
garage 
A type of cable with a corrugated sheath that has a maximum bend radius of 7 times the cable diameter is _____. 
Type MC 
a residence with 1,000 square feet of living space has a general lighting load of _____. 
3,000 VA 
According to the NEC®, the small appliance loads in each kitchen area of a dwelling must be served by at least ...
Residential Electrician Exam #1Complete Questions With 100% Correct Answers. 
Ferrous metal enclosures for grounding electrode conductors shall be _____. 
a) electrically continuous 
b) electrically isolated 
c) not permitted 
d) rigid metal conduit (RMC) only 
A: electrically continuous 
Ref: 250.64(E) 
Unless listed for the control of other loads, general use dimmer switches shall only be used to control _____. 
a) switched receptacles for cord-connected incandescent luminaires 
b) permanently...
- Package deal
- Exam (elaborations)
- • 6 pages's •
-
Residential Electrical Services•Residential Electrical Services
-
Residential Electrical Services Complete Exam Bundle Graded A+!!!||FULLY SOLVED• By LectDan
Preview 2 out of 6 pages
Residential Electrician Exam #1Complete Questions With 100% Correct Answers. 
Ferrous metal enclosures for grounding electrode conductors shall be _____. 
a) electrically continuous 
b) electrically isolated 
c) not permitted 
d) rigid metal conduit (RMC) only 
A: electrically continuous 
Ref: 250.64(E) 
Unless listed for the control of other loads, general use dimmer switches shall only be used to control _____. 
a) switched receptacles for cord-connected incandescent luminaires 
b) permanently...
Residential Electrician Exam #2 Latest Questions With 100% Correct Answers Graded A+ 
The MAXIMUM height that kitchen countertop receptacle outlets may be installed above the countertop shall be _____. 
a) 12 inches 
b) 18 inches 
c) 20 inches 
d) 24 inches 
C: 20 inches 
Ref: 210.52(C)(5) 
For dwelling units, panelboards are permitted to be located in all the areas listed EXCEPT _____. 
a) hallways 
b) garages 
c) kitchens 
d) bathrooms 
D: bathrooms 
Ref: 240.24(E) 
The MAXIMUM number of groun...
- Package deal
- Exam (elaborations)
- • 6 pages's •
-
Residential Electrical Services•Residential Electrical Services
-
Residential Electrical Services Complete Exam Bundle Graded A+!!!||FULLY SOLVED• By LectDan
Preview 2 out of 6 pages
Residential Electrician Exam #2 Latest Questions With 100% Correct Answers Graded A+ 
The MAXIMUM height that kitchen countertop receptacle outlets may be installed above the countertop shall be _____. 
a) 12 inches 
b) 18 inches 
c) 20 inches 
d) 24 inches 
C: 20 inches 
Ref: 210.52(C)(5) 
For dwelling units, panelboards are permitted to be located in all the areas listed EXCEPT _____. 
a) hallways 
b) garages 
c) kitchens 
d) bathrooms 
D: bathrooms 
Ref: 240.24(E) 
The MAXIMUM number of groun...
Residential Electrical Test (residential electric) Complete Questions with 100% Correct Answers 
the NEC is the basic standard; local and state codes are to be considered also. 
What code sets standards for electrical installation work? 
The local electrical inspection authority 
what authority enforces the requirements set by the NEC? 
Minimum 
does the NEC provide minimum or maximum standards? 
When shown on an electrical product or in a certification mark, it means the product is Listed by Un...
- Package deal
- Exam (elaborations)
- • 6 pages's •
-
Residential Electrical Services•Residential Electrical Services
-
Residential Electrical Services Complete Exam Bundle Graded A+!!!||FULLY SOLVED• By LectDan
Preview 2 out of 6 pages
Residential Electrical Test (residential electric) Complete Questions with 100% Correct Answers 
the NEC is the basic standard; local and state codes are to be considered also. 
What code sets standards for electrical installation work? 
The local electrical inspection authority 
what authority enforces the requirements set by the NEC? 
Minimum 
does the NEC provide minimum or maximum standards? 
When shown on an electrical product or in a certification mark, it means the product is Listed by Un...
Residential Electrical Test (residential electric) Complete Questions with 100% Correct Answers 
the NEC is the basic standard; local and state codes are to be considered also. 
What code sets standards for electrical installation work? 
The local electrical inspection authority 
what authority enforces the requirements set by the NEC? 
Minimum 
does the NEC provide minimum or maximum standards? 
When shown on an electrical product or in a certification mark, it means the product is Listed by Un...
- Package deal
- Exam (elaborations)
- • 2 pages's •
-
Residential Electrical Services•Residential Electrical Services
-
Residential Electrical Services Complete Exam Bundle Graded A+!!!||FULLY SOLVED• By LectDan
Preview 1 out of 2 pages
Residential Electrical Test (residential electric) Complete Questions with 100% Correct Answers 
the NEC is the basic standard; local and state codes are to be considered also. 
What code sets standards for electrical installation work? 
The local electrical inspection authority 
what authority enforces the requirements set by the NEC? 
Minimum 
does the NEC provide minimum or maximum standards? 
When shown on an electrical product or in a certification mark, it means the product is Listed by Un...
Residential Electrical Test (residential electric) Complete Questions with 100% Correct Answers 
the NEC is the basic standard; local and state codes are to be considered also. 
What code sets standards for electrical installation work? 
The local electrical inspection authority 
what authority enforces the requirements set by the NEC? 
Minimum 
does the NEC provide minimum or maximum standards? 
When shown on an electrical product or in a certification mark, it means the product is Listed by Un...
- Package deal
- Exam (elaborations)
- • 2 pages's •
-
Residential Electrical Services•Residential Electrical Services
-
Residential Electrical Services Complete Exam Bundle Graded A+!!!||FULLY SOLVED• By LectDan
Preview 1 out of 2 pages
Residential Electrical Test (residential electric) Complete Questions with 100% Correct Answers 
the NEC is the basic standard; local and state codes are to be considered also. 
What code sets standards for electrical installation work? 
The local electrical inspection authority 
what authority enforces the requirements set by the NEC? 
Minimum 
does the NEC provide minimum or maximum standards? 
When shown on an electrical product or in a certification mark, it means the product is Listed by Un...
Residential Electrical Services Quizzes With 100% Correct Answers. Graded A+ 
 
An example of a location in a dwelling where a receptacle must have a GFCI protection is a 
Garage 
A type of cable with a corrugated sheath that has a maximum bend radius of 7 times the cable diameter is 
Type MC 
A residence with 1,000 square feet of living space has a general lighting load of 
3000va 
According to the NEC, the small appliance loads in each kitchen area of a dwelling must be served by at least 
Two...
- Exam (elaborations)
- • 2 pages's •
-
Residential Electrical Services•Residential Electrical Services
Preview 1 out of 2 pages
Residential Electrical Services Quizzes With 100% Correct Answers. Graded A+ 
 
An example of a location in a dwelling where a receptacle must have a GFCI protection is a 
Garage 
A type of cable with a corrugated sheath that has a maximum bend radius of 7 times the cable diameter is 
Type MC 
A residence with 1,000 square feet of living space has a general lighting load of 
3000va 
According to the NEC, the small appliance loads in each kitchen area of a dwelling must be served by at least 
Two...
Residential Electrician Exam #1Complete Questions With 100% Correct Answers. Graded A+ 
 
Ferrous metal enclosures for grounding electrode conductors shall be _____. 
a) electrically continuous 
b) electrically isolated 
c) not permitted 
d) rigid metal conduit (RMC) only 
A: electrically continuous 
Ref: 250.64(E) 
Unless listed for the control of other loads, general use dimmer switches shall only be used to control _____. 
a) switched receptacles for cord-connected incandescent luminaires 
b)...
- Exam (elaborations)
- • 6 pages's •
-
Residential Electrical Services•Residential Electrical Services
Preview 2 out of 6 pages
Residential Electrician Exam #1Complete Questions With 100% Correct Answers. Graded A+ 
 
Ferrous metal enclosures for grounding electrode conductors shall be _____. 
a) electrically continuous 
b) electrically isolated 
c) not permitted 
d) rigid metal conduit (RMC) only 
A: electrically continuous 
Ref: 250.64(E) 
Unless listed for the control of other loads, general use dimmer switches shall only be used to control _____. 
a) switched receptacles for cord-connected incandescent luminaires 
b)...
Residential Electrical Test (residential electric) Complete Questions with 100% Correct Answers Graded A+ 
 
the NEC is the basic standard; local and state codes are to be considered also. 
What code sets standards for electrical installation work? 
The local electrical inspection authority 
what authority enforces the requirements set by the NEC? 
Minimum 
does the NEC provide minimum or maximum standards? 
When shown on an electrical product or in a certification mark, it means the product is ...
- Exam (elaborations)
- • 5 pages's •
-
Residential Electrical Services•Residential Electrical Services
Preview 2 out of 5 pages
Residential Electrical Test (residential electric) Complete Questions with 100% Correct Answers Graded A+ 
 
the NEC is the basic standard; local and state codes are to be considered also. 
What code sets standards for electrical installation work? 
The local electrical inspection authority 
what authority enforces the requirements set by the NEC? 
Minimum 
does the NEC provide minimum or maximum standards? 
When shown on an electrical product or in a certification mark, it means the product is ...