EWRB Theory Exam Prep Complete with Latest Questions and A+ Graded Verified Answers 
What is the minimum value of the permitted test result for the insulation resistance test of a three-phase, 400V, mains cable? 
1MΩ 
When carrying out testing on a low voltage electrical installation, which document details the tests and checks required to be carried out? 
AS/NZS 3000 
What is the minimum or maximum test result value you would consider acceptable for an Earth Continuity test? 
1Ω or less 
Stat...
- Exam (elaborations)
- • 58 pages's •
-
EWRB•EWRB
Preview 4 out of 58 pages
Getting your document ready...
EWRB Theory Exam Prep Complete with Latest Questions and A+ Graded Verified Answers 
What is the minimum value of the permitted test result for the insulation resistance test of a three-phase, 400V, mains cable? 
1MΩ 
When carrying out testing on a low voltage electrical installation, which document details the tests and checks required to be carried out? 
AS/NZS 3000 
What is the minimum or maximum test result value you would consider acceptable for an Earth Continuity test? 
1Ω or less 
Stat...
EWRB Theory Exam Prep ACTUAL 
QUESTIONS AND CORRECT ANSWERS 
What is the minimum value of the permitted test result for the insulation resistance test of a 
three-phase, 400V, mains cable? - CORRECT ANSWERS1MΩ 
When carrying out testing on a low voltage electrical installation, which document details the 
tests and checks required to be carried out? - CORRECT ANSWERSAS/NZS 3000 
What is the minimum or maximum test result value you would consider acceptable for an 
Earth Continuity test? ...
- Exam (elaborations)
- • 9 pages's •
-
EWRB•EWRB
Preview 2 out of 9 pages
Getting your document ready...
EWRB Theory Exam Prep ACTUAL 
QUESTIONS AND CORRECT ANSWERS 
What is the minimum value of the permitted test result for the insulation resistance test of a 
three-phase, 400V, mains cable? - CORRECT ANSWERS1MΩ 
When carrying out testing on a low voltage electrical installation, which document details the 
tests and checks required to be carried out? - CORRECT ANSWERSAS/NZS 3000 
What is the minimum or maximum test result value you would consider acceptable for an 
Earth Continuity test? ...
EWRB THEORY EXAM QUESTIONS WITH CORRECT ANSWERS LATEST UPDATE 2025 
What does BJT stand for? - Answers Bipolar Junction Transistor 
What does the transducer do? - Answers converts energy from one form to another 
State one factor that determines voltage drop - Answers Length of cable 
State one reason why a class 1 electrical appliance is set at a maximum of 1 ohm - Answers It prevents the touch voltages rising to dangerous levels 
State the test voltage used for carrying out an insulation resis...
- Exam (elaborations)
- • 2 pages's •
-
EWRB•EWRB
Preview 1 out of 2 pages
Getting your document ready...
EWRB THEORY EXAM QUESTIONS WITH CORRECT ANSWERS LATEST UPDATE 2025 
What does BJT stand for? - Answers Bipolar Junction Transistor 
What does the transducer do? - Answers converts energy from one form to another 
State one factor that determines voltage drop - Answers Length of cable 
State one reason why a class 1 electrical appliance is set at a maximum of 1 ohm - Answers It prevents the touch voltages rising to dangerous levels 
State the test voltage used for carrying out an insulation resis...
ELECTRICAL THEORY PRACTICE TEST EXAM QUESTIONS AND ANSWERS WITH ACTUAL SOLUTIONS VERIFIED 
Voltmeter 
A high resistance is connected in series with the internal coil of a galvanometer to make? 
If a transformer ratio is 20/1, what does it mean for the secondary? 
The primary voltage is 20 times greater than that of the secondary. 
If a motor enclosure is designed to contain sparks or flashes that could ignite surrounding vapors or gases, then the enclosure is considered to be which of the follow...
- Exam (elaborations)
- • 5 pages's •
-
EWRB•EWRB
Preview 2 out of 5 pages
Getting your document ready...
ELECTRICAL THEORY PRACTICE TEST EXAM QUESTIONS AND ANSWERS WITH ACTUAL SOLUTIONS VERIFIED 
Voltmeter 
A high resistance is connected in series with the internal coil of a galvanometer to make? 
If a transformer ratio is 20/1, what does it mean for the secondary? 
The primary voltage is 20 times greater than that of the secondary. 
If a motor enclosure is designed to contain sparks or flashes that could ignite surrounding vapors or gases, then the enclosure is considered to be which of the follow...
EWRB THEORY PREP - LOTO EXAM QUESTIONS AND ANSWERS WITH COMPLETE SOLUTIONS VERIFIED 
LOTO 
Lock Out Tag Out 
examples for protective /isolating device 
Disconnect Switch, MCB, Line valves 
LOTO tags must _____ the employee 
IDENTIFY employee 
LOTO devices shall be standard 1,2,3 
1, colour 
2, shape 
3, size 
LOTO procedures can only b performed by ______ 
authorized employees 
4 stored energy sources include 
1, springs 
2, hydraulics 
3, tension 
4, electricity 
purpose of LOTO 
To prevent the...
- Exam (elaborations)
- • 5 pages's •
-
EWRB•EWRB
Preview 2 out of 5 pages
Getting your document ready...
EWRB THEORY PREP - LOTO EXAM QUESTIONS AND ANSWERS WITH COMPLETE SOLUTIONS VERIFIED 
LOTO 
Lock Out Tag Out 
examples for protective /isolating device 
Disconnect Switch, MCB, Line valves 
LOTO tags must _____ the employee 
IDENTIFY employee 
LOTO devices shall be standard 1,2,3 
1, colour 
2, shape 
3, size 
LOTO procedures can only b performed by ______ 
authorized employees 
4 stored energy sources include 
1, springs 
2, hydraulics 
3, tension 
4, electricity 
purpose of LOTO 
To prevent the...
EWRB THEORY PREP - MCBS EXAM QUESTIONS WITH ANSWERS 100% GUARANTEED PASS LATEST UPDATE 
types of MCB trips 
thermal 
magnetic 
thermal tripping 
bi-metal strip, used for overload currents protection 
magnetic tripping 
magnetic inductor, used for short circuit protection 
reset procedure 
reset to OFF 
reset to ON 
arc containment includes 
horns carry current to chute, allow arc to jump out 
arc chute lengthens distance for arc to travel 
oil suppresses arc 
splitter plates split the arc 
arc c...
- Package deal
- Exam (elaborations)
- • 5 pages's •
-
EWRB•EWRB
-
BUNDLE OF EWRB EXAMS QUESTIONS AND ANSWERS WITH COMPLETE SOLUTIONS VERIFIED GRADED A++• By NurseAdvocate
Preview 2 out of 5 pages
Getting your document ready...
EWRB THEORY PREP - MCBS EXAM QUESTIONS WITH ANSWERS 100% GUARANTEED PASS LATEST UPDATE 
types of MCB trips 
thermal 
magnetic 
thermal tripping 
bi-metal strip, used for overload currents protection 
magnetic tripping 
magnetic inductor, used for short circuit protection 
reset procedure 
reset to OFF 
reset to ON 
arc containment includes 
horns carry current to chute, allow arc to jump out 
arc chute lengthens distance for arc to travel 
oil suppresses arc 
splitter plates split the arc 
arc c...
EWRB ELECTRICAL REGULATIONS EXAM QUESTIONS AND ANSWERS WITH COMPLETE SOLUTIONS GRADED A++ 
Section 1 of 3000 iis about? 
Fundamental Principles 
Section 2 of 3000 is about? 
Control and Protection 
Section 3 of 3000 is about? 
Wiring Systems 
Section 4 of 3000 is about
- Package deal
- Exam (elaborations)
- • 2 pages's •
-
EWRB•EWRB
-
BUNDLE OF EWRB EXAMS QUESTIONS AND ANSWERS WITH COMPLETE SOLUTIONS VERIFIED GRADED A++• By NurseAdvocate
Preview 1 out of 2 pages
Getting your document ready...
EWRB ELECTRICAL REGULATIONS EXAM QUESTIONS AND ANSWERS WITH COMPLETE SOLUTIONS GRADED A++ 
Section 1 of 3000 iis about? 
Fundamental Principles 
Section 2 of 3000 is about? 
Control and Protection 
Section 3 of 3000 is about? 
Wiring Systems 
Section 4 of 3000 is about
EWRB THEORY PREP RCD SPECS EXAM QUESTIONS AND ANSWERS WITH COMPLETE SOLUTIONS GRADED A++ 
RCD type AC 
detects and prevents imbalances in AC 
RCD personal protection (type ii) 
30mA, 300ms 
RCD property protection (PRCD) 
300mA
- Package deal
- Exam (elaborations)
- • 3 pages's •
-
EWRB•EWRB
-
BUNDLE OF EWRB EXAMS QUESTIONS AND ANSWERS WITH COMPLETE SOLUTIONS VERIFIED GRADED A++• By NurseAdvocate
Preview 1 out of 3 pages
Getting your document ready...
EWRB THEORY PREP RCD SPECS EXAM QUESTIONS AND ANSWERS WITH COMPLETE SOLUTIONS GRADED A++ 
RCD type AC 
detects and prevents imbalances in AC 
RCD personal protection (type ii) 
30mA, 300ms 
RCD property protection (PRCD) 
300mA
EWRB EXAM 49 QUESTIONS AND ANSWERS WITH COMPLETE SOLUTIONS GRADED A++ 
 
State the main reason why a large industrial electrical installation has a higher prospective short circuit current (PSSC) than a domestic electrical installation. 
The fault loop impedance is lower 
Because the distribution transformer is close to the installation or on-site 
A CT metering circuit is measuring the consumption of an industrial electrical installation at near to full load. The CT secondary must be shortcircu...
- Package deal
- Exam (elaborations)
- • 8 pages's •
-
EWRB•EWRB
-
BUNDLE OF EWRB EXAMS QUESTIONS AND ANSWERS WITH COMPLETE SOLUTIONS VERIFIED GRADED A++• By NurseAdvocate
Preview 2 out of 8 pages
Getting your document ready...
EWRB EXAM 49 QUESTIONS AND ANSWERS WITH COMPLETE SOLUTIONS GRADED A++ 
 
State the main reason why a large industrial electrical installation has a higher prospective short circuit current (PSSC) than a domestic electrical installation. 
The fault loop impedance is lower 
Because the distribution transformer is close to the installation or on-site 
A CT metering circuit is measuring the consumption of an industrial electrical installation at near to full load. The CT secondary must be shortcircu...
EWRB EXAM QUESTIONS 63 AND ANSWERS WITH COMPLETE SOLUTIONS LATEST UPDATE 
 
In New Zealand, the standard distribution system has the neutral conductor connected to the earth at the main switchboard on all low voltage installations. What name is given to this type of system? 
Multiple Earthed Neutral or MEN system. 
State the test voltage used for carrying out an insulation resistance test on three-phase, 400V, electrical equipment incorporating MIMS elements. 
500v dc 
State one reason why the r...
- Package deal
- Exam (elaborations)
- • 7 pages's •
-
EWRB•EWRB
-
BUNDLE OF EWRB EXAMS QUESTIONS AND ANSWERS WITH COMPLETE SOLUTIONS VERIFIED GRADED A++• By NurseAdvocate
Preview 2 out of 7 pages
Getting your document ready...
EWRB EXAM QUESTIONS 63 AND ANSWERS WITH COMPLETE SOLUTIONS LATEST UPDATE 
 
In New Zealand, the standard distribution system has the neutral conductor connected to the earth at the main switchboard on all low voltage installations. What name is given to this type of system? 
Multiple Earthed Neutral or MEN system. 
State the test voltage used for carrying out an insulation resistance test on three-phase, 400V, electrical equipment incorporating MIMS elements. 
500v dc 
State one reason why the r...