100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4.2 TrustPilot
logo-home
Tentamen (uitwerkingen)

Refrigeration Excellence Exam Questions and Answers Graded A+

Beoordeling
-
Verkocht
-
Pagina's
40
Cijfer
A+
Geüpload op
02-12-2025
Geschreven in
2025/2026

Refrigeration Excellence Exam Questions and Answers Graded A+

Instelling
AHA CPR
Vak
AHA CPR











Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
AHA CPR
Vak
AHA CPR

Documentinformatie

Geüpload op
2 december 2025
Aantal pagina's
40
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

Refrigeration Excellence Exam Questions
and Answers Graded A+

1. In a dry type (direct expansion) evaporator, liquid refrigerant must boil away as

close to the end of the coil as possible in order to:

A. Operate at high-efficiency

B. Ensure that Frost is not accumulate

C. Subcool the compressor

D. Ensure proper oil return - Correct answer-A. Operate at high-efficiency

2. The difference between the temperature of the refrigerant boiling in the

evaporator and the temperature at the evaporator outlet is known as

A. Evaporator superheat

B. Latent heat

C. Evaporator sub-cooling

D. Sublimation - Correct answer-A. Evaporator superheat

3. An expansion device that is stuck open will cause
©COPYRIGHT 2025, ALL RIGHTS RESERVED 1

,A. Low suction pressure

B. A starved evaporator

C. Excessive superheat

D. A flooded evaporator - Correct answer-D. A flooded evaporator

4. When measuring evaporator superheat on a commercial system that has a long

suction line, the pressure reading should be taken at the

A. Compressor inlet

B. Evaporator outlet

C. Condenser outlet

D. Receiver Inlet - Correct answer-A. Compressor inlet

5. Superheat measurements are best taken

A. During a hot pulldown

B. At 8°F two 12°F

C. During defrost

D. With the system operating at design conditions - Correct answer-D. With the

system operating at design conditions



©COPYRIGHT 2025, ALL RIGHTS RESERVED 2

,6. A technician is checking the superheat on a multi circuit evaporator and finds

one of the circuits has a superheat that is higher than the others. This could be

caused by

A. A dirty coil

B. A refrigerant overcharge

C. Uneven air distribution

D. A blocked distributor - Correct answer-D. A blocked distributor

7. A TXV with an external equalizer is used on

A. Evaporators with a high pressure drop

B. Evaporators with a low pressure drop

C. High temperature application is only

D. All evaporators - Correct answer-A. Evaporators with a high pressure drop

8. Dry type evaporators operate most efficiently with the superheat setting of

approximately

A. 8°F to 12°F

B. 13°F to 19°F

C. 20°F to 30°F
©COPYRIGHT 2025, ALL RIGHTS RESERVED 3

, D. 31°F to 40°F - Correct answer-A. 8°F to 12°F

9. An evaporator used to chill liquids is operating within normal superheat setting.

But the system is not cooling the product properly. Which of the following is most

likely the cause?

A. Overcharge of refrigerant

B. Undercharge of refrigerant

C. The circulator

D. The TXV - Correct answer-A. Overcharge of refrigerant

10. What time interval is required between each superheat adjustment?

A. Not less than one hour

B. About 10 to 15 minutes

C. At least a half hour

D. No time delay - Correct answer-B. About 10 to 15 minutes

11. A low temperature evaporator used for cooling space or product refrigeration

A. Is the same as one used for medium or high temperatures

B. Must have fins space closer together



©COPYRIGHT 2025, ALL RIGHTS RESERVED 4
€11,17
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten

Maak kennis met de verkoper
Seller avatar
EmmaGrants

Maak kennis met de verkoper

Seller avatar
EmmaGrants Howard Community College
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
Nieuw op Stuvia
Lid sinds
4 weken
Aantal volgers
0
Documenten
964
Laatst verkocht
-
Howard Community College Study Hub.

Welcome to HCC Study Hub, your go-to place for top-quality study materials from Howard Community College. Whether you're prepping for exams or just consolidating your notes, you'll find: -Lecture notes from past courses -Practice exams with detailed answers -Comprehensive study guides -Package deals for full semester bundles All documents are carefully reviewed, accurate, and designed to help you succeed. Uploads are updated regularly based on the latest course syllabi. Happy studying — and good luck!

Lees meer Lees minder
0,0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen