Journeyman and Master Plumbing Exam Question Bank| Actual Exam Questions and 100% Correct Answers| Latest Update
Journeyman and Master Plumbing Exam Question Bank| Actual Exam Questions and 100% Correct Answers| Latest Update What degree is used for isometric drawings? 60 degrees What is the recommended minimum of minutes for chlorine water management? 20-30 minutes When you need to repair a single handle lavatory faucet, what needs to be replaced? O ring Galvanic corrosion of water supply piping can occur where steel pipe is joined to a dissimilar metal pipe Whenever necessary to make an inspection to enforce any of the provisions of the Code, an authorized representative may enter the premises at all reasonable times After completion of work and testing of sewer pipeline, who shall request inspection? Supervisor of job at job-site If the Administrative Authority requests that a new type of material be used on a project, who pays for the testing of the new material? Contractor When plumbing work is inspected and a "notice of correction" is served, how many days does the contractor have to correct the work? Within 10 days What is the vertical distance called that is between the lowest opening of a pipe fixture or appurtenance that is discharging waste to the overflow level of a fixture? Airgap, drainage A cleanout which has direct access without the necessity of removing any panel or door is defined to be readily accessible Distribution of water from any other source than intended is backflow Back-siphonage is defined as the flowing back of used, contaminated or polluted water from a plumbing fixture or vessel into a water supply pipe due to a negative pressure in such pipe The _________________________ is the pipe which carries potable water from a water meter to a building. building supply Backflow is defined as non-potable water or other liquids entering a potable water system Any group of two or more similar adjacent fixtures that discharge into a common horizontal waste branch is defined as a
Geschreven voor
- Instelling
- Master plumbing
- Vak
- Master plumbing
Documentinformatie
- Geüpload op
- 27 november 2025
- Aantal pagina's
- 59
- Geschreven in
- 2025/2026
- Type
- Tentamen (uitwerkingen)
- Bevat
- Vragen en antwoorden
Onderwerpen
-
journeyman and master plumbing exam question bank
-
what degree is used for isometric drawings
-
what is the recommended minimum of minutes for chl
-
when you need to repair a single handle lavatory f
Ook beschikbaar in voordeelbundel