High Voltage Holiday Detector Pannel - CORRECT ANSWER--When determining the Voltage used, if not shown on dial use Voltage immediately below what's needed -Remember the selection must be either High or Low and the corresponding number next to the Voltage. SSPC-PA2 - CORRECT ANSWER-Dry Film Thickness Gauge SSPC-PA2 Type 1 - CORRECT ANSWER-Magnetic Pull-Off DFT Gauge -Dial-Type Magnetic Pull-Off DFT Gauge (Banana Gauge) -Pencil Type Magnetic Pull-Off DFT Gauge Dial TypeMagnetic Pull-Off DFT Gauge - CORRECT ANSWER--Known as "Banana Gauge" -Intrinsically Safe -Some Models Can Be Used Underwater ASTM D 7091 - CORRECT ANSWER--Calibration: Gauge Shall be Calibrated by manufacturer or third party lab. -BMR: In order to compensate for any effects from the blast profile must calculate the Base Metal Reading. -Verify Accuracy: Use certified metal plates and Gauge must be within 5% of expected range. NACE SP0188 - CORRECT ANSWER-High and Low Voltage Holiday Testing Low-Voltage Holiday Detector - CORRECT ANSWER--Ground is attached directly to substrate. -Sponge saturated with a solution of tap water/wetting agent -Proper mix ratio 1oz/USgal -Proper of speed is 1ft/sec Double Stroke -Used on Coatings up to 20mils -may be used on concrete Low Voltage Holiday Detectors Common Errors - CORRECT ANSWER--Failure to Keep probe in contact with surface -Moving the electrode too fast or slow -Over or under saturating the sponge -Low battery or bad lead/ground connection Telegraphing - CORRECT ANSWER-Can occur when surface is saturated with water and the Detector reads a different area.High Voltage Holiday Detectors - CORRECT ANSWER--Can have an Output range from 800-60,000v -In General Voltage ratio 100v/1mil -Electrode Rate of 1ft/sec with a single pass -Ground connection must be made direct to metal substrate(preferred) or indirectly for pipeline in soil. Type 1 DFT Gauge Adjustment - CORRECT ANSWER--Take 10 reading on the blasted steel surface and average the results. -Take DFT measurements - Subtract BMR from DFT Averages

Meer zien Lees minder
Instelling
NACE CIP Level 1 Practical
Vak
NACE CIP Level 1 Practical








Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
NACE CIP Level 1 Practical
Vak
NACE CIP Level 1 Practical

Documentinformatie

Geüpload op
14 november 2025
Aantal pagina's
2
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

NACE CIP Level 1 Practical Exam
High Voltage Holiday Detector Pannel - CORRECT ANSWER--When determining the
Voltage used, if not shown on dial use Voltage immediately below what's needed
-Remember the selection must be either High or Low and the corresponding number
next to the Voltage.

SSPC-PA2 - CORRECT ANSWER-Dry Film Thickness Gauge

SSPC-PA2 Type 1 - CORRECT ANSWER-Magnetic Pull-Off DFT Gauge
-Dial-Type Magnetic Pull-Off DFT Gauge (Banana Gauge)
-Pencil Type Magnetic Pull-Off DFT Gauge

Dial TypeMagnetic Pull-Off DFT Gauge - CORRECT ANSWER--Known as "Banana
Gauge"
-Intrinsically Safe
-Some Models Can Be Used Underwater

ASTM D 7091 - CORRECT ANSWER--Calibration: Gauge Shall be Calibrated by
manufacturer or third party lab.
-BMR: In order to compensate for any effects from the blast profile must calculate the
Base Metal Reading.
-Verify Accuracy: Use certified metal plates and Gauge must be within 5% of expected
range.

NACE SP0188 - CORRECT ANSWER-High and Low Voltage Holiday Testing

Low-Voltage Holiday Detector - CORRECT ANSWER--Ground is attached directly to
substrate.
-Sponge saturated with a solution of tap water/wetting agent
-Proper mix ratio 1oz/USgal
-Proper of speed is 1ft/sec Double Stroke
-Used on Coatings up to 20mils
-may be used on concrete

Low Voltage Holiday Detectors Common Errors - CORRECT ANSWER--Failure to Keep
probe in contact with surface
-Moving the electrode too fast or slow
-Over or under saturating the sponge
-Low battery or bad lead/ground connection

Telegraphing - CORRECT ANSWER-Can occur when surface is saturated with water
and the Detector reads a different area.

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
ACADEMICMATERIALS City University New York
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
562
Lid sinds
2 jaar
Aantal volgers
186
Documenten
10590
Laatst verkocht
1 dag geleden

4,1

95 beoordelingen

5
53
4
11
3
21
2
3
1
7

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen