100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4.2 TrustPilot
logo-home
Tentamen (uitwerkingen)

Surgical Technology Certification

Beoordeling
-
Verkocht
-
Pagina's
58
Cijfer
A+
Geüpload op
10-11-2025
Geschreven in
2025/2026

Surgical Technology Certification

Instelling
Surgical Tech
Vak
Surgical tech











Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Surgical tech
Vak
Surgical tech

Documentinformatie

Geüpload op
10 november 2025
Aantal pagina's
58
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

Surgical Technology Certification
2025/2026
EXAM ACTUAL EXAM QUESTIONS AND
WELL ELABORATED ANSWERS WITH
(100% VERIFIED SOLUTIONS) LATEST
UPDATES | ALREADY GRADED A+




How often must a biological control test be run? a.
every day
b. every cycle
c. once a week
d. once a month -
ANSWER>>ANSWER: A [pg. 163]


The Bowie-Dick test for pre-vacuum sterilizers checks for which of the
following conditions?
a. that the appropriate steam level was reached
b. air leaks in the sterilizer chamber
c. broken sterilizer jacket
d. that the sterilizer is ready to process instruments -
ANSWER>>ANSWER: B

,lot control numbers should be placed on each package sterilized and on
the...
a. sterilizer maintenance record
b. sterilization load record
c. nursing documentation
d. cover of the patient's chart - ANSWER>>ANSWER: B


How long is a 3M Attest 1292 steam biological indicator incubated before
the reading is recorded? a. 12 hours
b. 36 hours
c. 24 hours
d. 48 hours - ANSWER>>ANSWER:
C 12 hours - rapid ; 24 hours - not
rapid


During a vascular procedure a vessel is ligated. The surgeon states that
she will repair the vessel after bleeding is controlled. Which needle type
would she most likely require to complete this task? a. control release
needle
b. French eyed needle
c. tapered needle
d. cutting needle - ANSWER>>ANSWER: C

When steam sterilizing biological indicators, how long are they incubated
before the reading is recorded? a. 48 hours
b. 24 hours
c. 12 hours
d. 72 hours - ANSWER>>ANSWER: B

,An OB-GYN surgeon has posted a laparoscopic partial hysterectomy and
has informed the surgical team that the ovaries are remaining. However,
the fallopian tubes will require ligation involoving the tubes being clipped
and cauterized. Which of the following instruments should the surgical
technologist open
a. a Flishie and hemoclip applier
b. a Flishie and Kleppinger
c. a Kleppinger and harmonic scalpel
d. a harmonic scalpel and hemoclip applier - ANSWER>>ANSWER: D


Which of the following instruments can be decontaminated in the
washersterilizer?
a. colonoscope
b. power drill
c. laser coated instrument set
d. phaco instrument set - ANSWER>>ANSWER: C


The patient has undergone cardiac bypass surgery. Protamine has been
administered and the surgeon is preparing to close the sternotomy.

Bleeding is a postoperative concern. Which of the following systems should
the surgical technologist anticipate the surgeon will use? a. Hemovac
b. Jackson Pratt
c. Pleur-Evac
d. Penrose - ANSWER>>ANSWER: C

, A patient presents to the operating room for irrigation and debridement of a
wound caused by penetrating trauma. The surgeon states that the wound
will heal by secondary intention. Which of the following dressing types
should the surgical technologist ask the circulator for? a. ABD
b. bolsters
c. bio-occlusive strips
d. Steri-strips - ANSWER>>ANSWER: A


During an abdominoperineal repair, which of the following is the most
appropriate stapler to assemble and hand to the surgeon to perform an
anastomosis between the proximal and distal ends of the colon? a. TA
b. GIA
c. EEA
d. LDS - ANSWER>>ANSWER: C


A pressure dressing is most likely applied over a a.
TURP
b. skin graft
c. fractured femur EX fix
d. cataract surgery - ANSWER>>ANSWER: B


During an open laparotomy the surgeon drops a Poole suction tip before
irrigating. It is the only suction tip available and it has to be re-sterilized to
be used later in the procedure. Which of the following types of
sterilization should the surgical technologist use? a. ethylene oxide
b. gravity displacement
c. pre vac

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
AndrewBenson Johns Hopkins University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
19
Lid sinds
10 maanden
Aantal volgers
0
Documenten
1945
Laatst verkocht
6 dagen geleden

3,0

2 beoordelingen

5
1
4
0
3
0
2
0
1
1

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen