QUESTIONS AND ANSWERS 100% PASS
“what are the 3 basic parts of combustion? - CORRECT ANSWER fuel, heat, air"
"high pressure oil forced through a nozzle does what? - CORRECT ANSWER atomizes
the oil, mixes the droplets with air, allows oil to burn"
"ignition point is what? - CORRECT ANSWER lowest temp at which rapid combustion
of the fuel will take place in the air"
"pour point #2 oil is what? - CORRECT ANSWER lowest temp at which oil will flow"
"as oil gets colder does the viscosity increase or decrease? - CORRECT ANSWER
increases"
"water in the bottom of the tank will lead to what two things? - CORRECT ANSWER
sludge and ice"
"sludge is a combination of what three things? - CORRECT ANSWER water, bacteria,
degraded fuel and other contaminants"
"sulfur in fuel creates sulfuric acid in condensed flue gasses, what are the three most
common adverse effects on this? - CORRECT ANSWER damages the flue liner, eats
holes in the flue pipe, creates scale buildup in the heat exchanger"
"to insure clean, uncontaminated fuel reaches the oil burner. what three things should we
do? - CORRECT ANSWER install tank properly, regularly inspect and fix minor defects
before they lead to major problems, install a quality oil filter"
"if the vacuum is below calculation you may have what? - CORRECT ANSWER suction
line leak"
"if the vacuum is above calculation you may have what? - CORRECT ANSWER suction
line restriction/clogged"
"can a leak in the oil line pull in air without oil leaking? - CORRECT ANSWER yes"
1
,"a two stage pump is needed when you... - CORRECT ANSWER have a high lift and a
long run"
"what are the two benefits to a one pipe system - CORRECT ANSWER eliminates
worry's of leaking return lines, decreases frequency of replacing oil filters"
"a two pipe system can move ___ gallons of fuel thru the oil filter - CORRECT ANSWER
15"
"pulsating oil pump pressure and pulsating fame may be caused by? - CORRECT
ANSWER air leaks in the suction line"
"when the combustion gasses get too cold what happens? - CORRECT ANSWER the
water vapor in the flue gas will condense"
"what is a power venter and what is it used for? - CORRECT ANSWER a fan to pull
combustion products through the heat exchanger and out the building"
"a direct vent system relies on what to push gasses out the building - CORRECT
ANSWER the burner, pre-purge and post-purge control, proper installation"
"a sealed shut draft regulator causes what? - CORRECT ANSWER too much draft over
the fire"
"chimney draft is affected by... - CORRECT ANSWER temp difference in chimney and
outside air, barometric pressure, humidity and wind"
"air is made up of ____% oxygen and ____% nitrogen - CORRECT ANSWER 20.9% O2 and
78% N"
"a liquid co2 tester must be pumped how many times - CORRECT ANSWER 18"
"the fluid in a wet kit co2 tester is good for ____ uses - CORRECT ANSWER 200"
"a combustion test includes what measurements - CORRECT ANSWER stack temp,
draft, smoke, excess air (co2 and o2)"
"Incomplete combustion and carbon monoxide are caused by what? - CORRECT
ANSWER too little/too much air, flame impingement"
2
, "a co2 of 7% at the breech and 10% over the fire indicates? - CORRECT ANSWER
excess air leaks into the furnace or boiler"
"more air input for the fire increases... - CORRECT ANSWER stack temp"
"an electrical circuit for an oil burner will contain? - CORRECT ANSWER a conductor,
switches, and loads"
"the switching relays job is to... - CORRECT ANSWER control a line voltage load with a
low voltage thermostat"
The key final adjustment for most oil burners is? - CORRECT ANSWER Combustion Air"
"Dirt or lint build-up in the bevel of the burner fan blades will? - CORRECT ANSWER
Reduce the blade bevel and reduce the amount of air delivered"
"To change the air ratio for different firing rates with an adjustable head burner you? -
CORRECT ANSWER Move the head forward or backward, against or away from the ring
closing or opening the tertiary slot"
"Excessive draft drop through the heat exchanger indicates? - CORRECT ANSWER
Heavy soot and scale deposit. Dirty heat exchanger"
"When the combustion gasses get too cold? - CORRECT ANSWER Water vapor in flue
gasses will condense back into water"
"Power venters use? - CORRECT ANSWER A fan to pull combustion gasses through the
heat exchanger and out of the building"
"About 21% of air is made up of? - CORRECT ANSWER Oxygen"
"When using a pump type smoke tester, ten full strokes are necessary to? - CORRECT
ANSWER Draw the proper amount of gases through the paper"
"As more air is added to the fire? - CORRECT ANSWER Co2 goes down and O2 goes up"
3