Questions 1-20 | NFPA 72, IBC, ADA Requirements Question 1 According to NFPA 72, what is the maximum spacing for smoke detectors in a smooth ceiling? A) 20 feet B) 30 feet C) 40 feet D) 50 feet EXPLANATION NFPA 72-17.7.3.2.3.1 - Smoke detectors on smooth ceilings have a maximum spacing of 30 feet (9.1m) center-to-center. This assumes 30-foot diameter coverage area per detector with proper overlap. KEY POINT Spacing may be reduced for irregular ceilings, beams, joists, or air handling considerations. Always consider ceiling height and configuration. Question 2 What is the minimum height for wall-mounted visual notification appliances (strobes)? A) 60 inches B) 70 inches C) 80 inches D) 90 inches EXPLANATION NFPA 72-18.5.5.1 - Wall-mounted visual appliances must be mounted with the entire lens between 80 inches (2.0m) minimum and 96 inches (2.4m) maximum above the finished floor. This ensures visibility for all occupants. Question 3 What is the required flash rate for visual notification appliances? A) 0.5 to 1 Hz B) 1 to 2 Hz C) 2 to 3 Hz D) 3 to 4 Hz EXPLANATION NFPA 72-18.5.2.1 - Visual notification appliances must flash at a rate of 1 to 2 flashes per second (1 to 2 Hz). This rate is optimal for alerting occupants without triggering photosensitive epilepsy. ️ IMPORTANT Synchronization of strobes is required when multiple devices are visible in the same field of view to prevent disorientation. Question 4 How often must fire alarm systems be tested and inspected? A) Annually B) Semi-annually C) Quarterly D) Monthly EXPLANATION NFPA 72-14.3.1 - Complete fire alarm system testing and inspection must be performed at least annually. Some components require more frequent testing (e.g., battery tests, backup power monthly; alarm notification appliance semi-annually). Question 5 What is the maximum distance from any point in a corridor to a manual pull station? A) 100 feet B) 150 feet C) 200 feet D) 250 feet

Meer zien Lees minder
Instelling
Revision
Vak
Revision









Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Revision
Vak
Revision

Documentinformatie

Geüpload op
1 oktober 2025
Aantal pagina's
7
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

NICET
Level II Certification
Fire Alarm Systems
Practice Exam 2025/2026
100 Questions
Complete with Detailed Explanations & Code References

PART 1: CODES & STANDARDS
Questions 1-20 | NFPA 72, IBC, ADA Requirements
Question 1
According to NFPA 72, what is the maximum spacing for smoke detectors in a
smooth ceiling?
A) 20 feet
B) 30 feet
C) 40 feet
D) 50 feet
💡 EXPLANATION

NFPA 72-17.7.3.2.3.1 - Smoke detectors on smooth ceilings have a maximum spacing of 30
feet (9.1m) center-to-center. This assumes 30-foot diameter coverage area per detector with proper
overlap.
✓ KEY POINT

Spacing may be reduced for irregular ceilings, beams, joists, or air handling considerations. Always consider ceiling
height and configuration.
Question 2
What is the minimum height for wall-mounted visual notification appliances
(strobes)?
A) 60 inches
B) 70 inches
C) 80 inches

, D) 90 inches
💡 EXPLANATION

NFPA 72-18.5.5.1 - Wall-mounted visual appliances must be mounted with the entire lens between 80
inches (2.0m) minimum and 96 inches (2.4m) maximum above the finished floor. This ensures visibility
for all occupants.
Question 3
What is the required flash rate for visual notification appliances?
A) 0.5 to 1 Hz
B) 1 to 2 Hz
C) 2 to 3 Hz
D) 3 to 4 Hz
💡 EXPLANATION

NFPA 72-18.5.2.1 - Visual notification appliances must flash at a rate of 1 to 2 flashes per second (1
to 2 Hz). This rate is optimal for alerting occupants without triggering photosensitive epilepsy.
⚠️ IMPORTANT

Synchronization of strobes is required when multiple devices are visible in the same field of view to prevent
disorientation.
Question 4
How often must fire alarm systems be tested and inspected?
A) Annually
B) Semi-annually
C) Quarterly
D) Monthly
💡 EXPLANATION

NFPA 72-14.3.1 - Complete fire alarm system testing and inspection must be performed at
least annually. Some components require more frequent testing (e.g., battery tests, backup power
monthly; alarm notification appliance semi-annually).
Question 5
What is the maximum distance from any point in a corridor to a manual pull
station?
A) 100 feet
B) 150 feet
C) 200 feet
D) 250 feet

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
Abbyy01 Exam Questions
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
91
Lid sinds
3 jaar
Aantal volgers
33
Documenten
1121
Laatst verkocht
3 weken geleden

3,5

13 beoordelingen

5
5
4
2
3
3
2
1
1
2

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen