100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

ASCP Hematology MLT Exam 1 & 2 Questions and Verified Solutions Latest Update This Year

Beoordeling
-
Verkocht
-
Pagina's
86
Cijfer
A+
Geüpload op
19-09-2025
Geschreven in
2025/2026

ASCP Hematology MLT Exam 1 & 2 Questions and Verified Solutions Latest Update This Year

Instelling
ASCP Hematology MLT
Vak
ASCP Hematology MLT











Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
ASCP Hematology MLT
Vak
ASCP Hematology MLT

Documentinformatie

Geüpload op
19 september 2025
Aantal pagina's
86
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

Page 1 of 86



ASCP Hematology MLT Exam 1 & 2 Questions and

Verified Solutions Latest Update This Year



ANSWER STARTS THEN QUESTION


ANSWER- A;

One of the key characteristics to the identification of Nocardia asteroides is its inability to

hydrolyze casein, tyrosine or xanthine, as shown in this photograph. Nitrates are reduced to

nitrites. Both Nocardia brasiliensis and Actinomadura madurae hydrolyze both casein and

tyrosine; Streptomyces griseus hydrolyzes all three of the substrates.


Illustrated in this photograph is an agar quadrant plate containing casein (A), tyrosine (B),

nitrate (C) and xanthine (D). None of the substrates have been hydrolyzed and nitrate has

been reduced. The most likely identification is:



A. Nocardia asteroides

B. Nocardia brasiliensis

C. Streptomyces griseus

D. Actinomadura madurae

, Page 2 of 86


A;

Since hemoglobin is measured spectrophotometrically on hematology analzyers, interference

from lipemia or icteric specimens can lead to decreased light detected and measured through

the sample and therefore inaccurate hemoglobin results occur.


On an electronic cell counter, hemoglobin determination may be falsely elevated caused by

the presence of:



A. Lipemic or icteric plasma

B. Leukocytopenia or Leukocytosis

C. Rouleaux or agglutinated RBCs

D. Anemia or Polycythemia


False

A patient who has a primarily vegetarian diet will most likely have an alkaline urine pH. A

low-carbohydrate diet as well as the ingestion of citrus fruits can also lead to a more alkaline

urine sample.


A patient who has a primarily vegetarian diet will most likely have an acid urine pH.


A;

During primary hypothyroidism, where a defect in the thryoid gland is producing low levels of

T3 and T4, the TSH level is increased. TSH is released in elevated quantities in an attempt to

stimulate the thryoid to produce more T3 and T4 as part of a feedback mechanism.

, Page 3 of 86


Serum TSH levels five-times the upper limit of normal in the presence of a low T4 and low T3

uptake could mean which of the following:



A. The thyroid has been established as the cause of hypothyroidism

B. The thyroid is ruled-out as the cause of hypothyroidism

C. The pituitary has been established as the cause of hypothyroidism

D. The diagnosis is consistent with secondary hyperthyroidism


B;

The correct answer for this question is 1300 mg/dL. The laboratorian performed a 1:4 dilution

by adding 0.25 mL (or 250 microliters) of patient sample to 750 microliters of diluent. This

creates a total volume of 1000 microliters. So, the patient sample is 250 microliters of the

1000 microliter mixed sample, or a ratio of 1:4. Therefore, the result given by the chemistry

analyzer must be multiplied by a dilution factor of 4. 325 mg/dL x 4 = 1300 mg/dL.


After experiencing extreme fatigue and polyuria, a patient's basic metabolic panel is analyzed in

the laboratory. The result of the glucose is too high for the instrument to read. The laboratorian

performs a dilution using 0.25 mL of patient sample to 750 microliters of diluent. The result

now reads 325 mg/dL. How should the techologist report this patient's glucose result?



A. 325 mg/dL

B. 1300 mg/dL

, Page 4 of 86


C. 975 mg/dL

D. 1625 mg/dL


A;

Conversion of only the slant to a pink color in a Christensen's urea agar slant is produced by

bacterial species that have weak urease activity. The reaction in the slant to the right is often

produced by Klebsiella species, as an example. Strong urease activity is indicated by

conversion of the slant and the butt of the tube to a pink color, as seen in the tube to the left.

The slant only reaction in the right tube may be seen early on if only the slant had been

inoculated; however, with a strong urease producer, both the slant and the butt would turn.

Therefore, the reaction is dependent on the strength of urease activity. If the media had

outdated for a prolonged period, either there would be no reaction or the appearance of only

a faint pink tinge, either in the slant, the butt or both, again depending on the strength of

urease production by the unknown organism.


The urease reaction seen in the Christensen's urea agar slant on the far right indicates:



A. Weak activity

B. Strong activity

C. Slant only inoculated

D. Use of outdated medium


D;

The steps in the PCR process are:

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
STUVIAGRADES Chamberlain College Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
6217
Lid sinds
4 jaar
Aantal volgers
450
Documenten
5909
Laatst verkocht
1 dag geleden
stuvia_US

Welcome To my Store# STUVIA_US My Goal is to help you achieve your desired grades by providing credible study materials I'm happy to help you with quality documents On this page you will find quality study guides,Exams assignments, Research papers and Test Banks all verified correct . you'll find past and recent revised and verified study materials . Stay here and You'll find everything you need to pass !!! . I always ensure my documents are of high standards I am always available to assist 24/7 and answer any queries you may have . Be assured to get good grades and always leave a review after a purchase Refer a friend SUCCESS!!!!

Lees meer Lees minder
4,8

1075 beoordelingen

5
993
4
27
3
22
2
11
1
22

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen