100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4.2 TrustPilot
logo-home
Tentamen (uitwerkingen)

EPA 608 Type III Sample Test Questions correctly answered already passed

Beoordeling
-
Verkocht
-
Pagina's
29
Cijfer
A+
Geüpload op
03-09-2025
Geschreven in
2025/2026

EPA 608 Type III Sample Test Questions correctly answered already passed 1. Where do leaks commonly occur in low pressure sys- tems? a. Evaporator b. Condenser c. Purge unit d. Gaskets or fittings 2. Where do leaks commonly occur in open-drive type compressor systems? a. Evaporator b. Condenser c. Shaft seal d. Cooling tower 3. Does refrigerant go out of the system in low pressure systems or does air and moisture go in? a. Refrigerant escapes through low pressure leaks. b. Air and moisture enter the refrigeration system be- cause it operates in a vacuum c. Refrigerant leaks out through shaft seals and gas- kets. 4. When should a low pressure system be leak checked according to ASHRAE guideline 3-1996? a. There are specific recommendations. b. During pressure checks c. When the system rises from 1 mm Hg to a level above 2.5 mm Hg d. Gaskets or fittings c. Shaft seal b. Air and moisture en- ter the refrigeration sys- tem because it operates in a vacuum

Meer zien Lees minder
Instelling
EPA 608 Type 3
Vak
EPA 608 Type 3










Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
EPA 608 Type 3
Vak
EPA 608 Type 3

Documentinformatie

Geüpload op
3 september 2025
Aantal pagina's
29
Geschreven in
2025/2026
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

EPA 608 Type III Sample Test Questions correctly
answered already passed
1. Where do leaks commonly occur in low level
pressure sys- tems? above
a. Evaporator 2.5 mm Hg
b. Condenser
c. Purge unit
d. Gaskets or fittings

2. Where do leaks commonly occur in open-
drive type compressor systems?
a. Evaporator
b. Condenser
c. Shaft seal
d. Cooling tower

3. Does refrigerant go out of the system in low
pressure systems or does air and
moisture go in?
a. Refrigerant escapes through low pressure
leaks.
b. Air and moisture enter the refrigeration
system be- cause it operates
in a vacuum
c. Refrigerant leaks out through shaft seals
and gas- kets.

4. When should a low pressure system be leak
checked according to ASHRAE
guideline 3-1996?
a. There are specific recommendations.
b. During pressure checks
c.When the system rises from 1 mm Hg to a


,EPA 608 Type III Sample Test Questions correctly
answered already passed
d. Gaskets or fittings




c. Shaft seal




b. Air and moisture en- ter the refrigeration sys- tem because it operates
in a vacuum




c. When the system rises from 1 mm Hg to a level above 2.5 mm
Hg during vacuum testing






, EPA 608 Type III Sample Test Questions correctly
answered already passed
during vacuum testing
d. Leak check every year

5. What does a purge unit do and what is a high efficiency d. Removes
the air from
purge unit? the system. High
eflciency
a. Removes the refrigerant from the system. High effi- purge system
will
ciency purge system compress
will expel large quantities of refrigerant or
b. Removes the refrigerant from the system. suction,
High effi- ciency purge system removes
will expel very little refrigerant the air
c. Removes the oil from the system. High from the
efficiency purge system will expel system, and
very little refrigerant returns the
d. Removes the air from the system. High refrigerant
efficiency purge system will to the
expel very little refrigerant evaporator
d. Takes
6. How does a centrifugal compressor purge unit its
work? suction
a. Takes its suction from the top of the from the
evaporator, removes the air from the top of
system, and returns the refrigerant to the the
evaporator
condens
b. Takes its suction from the top of the chiller
er,
barrel, removes the air from the
removes
system, and returns the refrigerant to the
the air
evaporator
c. Takes its suction from the top of the

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
BravelRadon Havard School
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
873
Lid sinds
4 jaar
Aantal volgers
540
Documenten
41485
Laatst verkocht
4 dagen geleden
EXAM HUB

Welcome to Exam Hub Are you looking for high-quality, exam-ready notes, past papers, Test Banks, and well-researched study materials to boost your grades? You’re in the right place! I create and upload detailed, easy-to-understand, and well-structured documents across multiple subjects. All my materials are designed to help you study , save time, and excel in your coursework and exams! On this page NURSING EXAMS,STUDY GUIDES,TESTBANKS AND QUALITY EXAMS IS THE KEY TO STUDENTS CAREER EXCELLENCE, you find all documents, package deals, and flashcards offered by BravelRadon (EXAM HUB STORES!)....kindly recommend a friend for A+ GARANTEEd either you are a first-year student or final-year graduation! best of luck!

Lees meer Lees minder
3,5

154 beoordelingen

5
56
4
30
3
32
2
8
1
28

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen