ICC California UST Service Technician Exam| Answered 100% Correctly| Updated
ICC California UST Service Technician Exam| Answered 100% Correctly| Updated UDC was required at time of installation for all systems installed after? January 1, 2000 July 1, 2005, service techs shall possess or work under someone who has a current certification indicating he or she has passed the? ICC UST Service Technician Exam ICC cert must be renewed every? 24 months Service techs must possess or be employed by a person who has the appropriate contractor's license unless? The individual has a tank testing license Service tech is defined by any individual who? Tests UST monitoring equipment, trouble shoots UST systems, and/or installs UST monitoring equipment. If the manufacturer training no longer exist, the local agency may? Approve comparable alternate training . UST includes? Tank and connected piping What is considered a UST? A petroleum storage tank. What UST system meets the requirements for secondary containment? Doubled wall tanks According to title 23; the following piping components if installed after July 1, 1987 must have secondary containment. Pressured product piping Considered "pipe" on tanks installed after July 1, 2003. Pressured product piping and below ground vapor recovery. Under dispenser containment (UDC) was required for all existing UST systems by December 31, 2003 System for exchanging gas vapors in a storage tank and product in a fuel delivery truck Stage 1 vapor recovery An approved method for non-visual monitoring for existing UST systems. Statistical Inventory Reconciliation (SIR) ATG must be capable for detecting a release of? 0.2 gallons per hour What is no longer an approved method for non-visual monitoring on existing UST systems? Manual inventory reconciliation. Automatic line leak detectors installed on underground piping with secondary containment shall be capable of detecting a leak of ? 3 gallons per hour at 10 psi How often should ATG be programmed to test the tank? At least monthly According to PEI RP 300, a combustible gas can be used to?
Geschreven voor
- Instelling
- ICC California UST Service Technician
- Vak
- ICC California UST Service Technician
Documentinformatie
- Geüpload op
- 25 juni 2025
- Aantal pagina's
- 51
- Geschreven in
- 2024/2025
- Type
- Tentamen (uitwerkingen)
- Bevat
- Vragen en antwoorden
Onderwerpen
-
icc california ust service technician exam
-
udc was required at time of installation for all
-
july 1 2005 service techs shall possess or work
-
icc cert must be renewed every
Ook beschikbaar in voordeelbundel