USP (795,797,800, 825) QUESTIONS WITH ANSWERS RATED
A+
USP 795 personal training - initially and at least every 12 months
USP 795 at minimum personnel must revmove - personal out garments
all hand, wrist, and other exposed jewelry
earbuds or headphones
minimum frequency for cleaning and sanitizing nonsterile compounding areas- surfaces - work
surfaces
- at the beginning and end of each shift on days when compounding occurs, after spills and when
surface contamination (from splashes) is known or suspected
- between compounding CNSPs with different components
floors
- daily on days when compounding occurs, after spills, and when surface contamination (from
splashes) is known or suspected
walls
- when visibly soiled, after spills and when surface contamination (from splashes) is known or
suspected
ceilings
- when visibly soiled, after spills and when surface contamination (from splashes) is known or
suspected
storage shelving
- every 3 months, after spills, and when surface contamination (from splashes) is known for
suspected
master formulation record - created before first compound product
- directions for what you should do
- a recipe book
compounding record - completed every time a compound is prepared
- documentation of what you did
expiration date vs BUD - from time manufactured to time used (max life of product)
BUD: from time compounded to time used
A+
USP 795 personal training - initially and at least every 12 months
USP 795 at minimum personnel must revmove - personal out garments
all hand, wrist, and other exposed jewelry
earbuds or headphones
minimum frequency for cleaning and sanitizing nonsterile compounding areas- surfaces - work
surfaces
- at the beginning and end of each shift on days when compounding occurs, after spills and when
surface contamination (from splashes) is known or suspected
- between compounding CNSPs with different components
floors
- daily on days when compounding occurs, after spills, and when surface contamination (from
splashes) is known or suspected
walls
- when visibly soiled, after spills and when surface contamination (from splashes) is known or
suspected
ceilings
- when visibly soiled, after spills and when surface contamination (from splashes) is known or
suspected
storage shelving
- every 3 months, after spills, and when surface contamination (from splashes) is known for
suspected
master formulation record - created before first compound product
- directions for what you should do
- a recipe book
compounding record - completed every time a compound is prepared
- documentation of what you did
expiration date vs BUD - from time manufactured to time used (max life of product)
BUD: from time compounded to time used