100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4.2 TrustPilot
logo-home
Tentamen (uitwerkingen)

Instrumental Analysis – Exam 2 Questions with Verified Answers – Atomic Spectroscopy, Mass Spectrometry, and Surface Characterization Techniques

Beoordeling
-
Verkocht
-
Pagina's
21
Cijfer
A+
Geüpload op
06-06-2025
Geschreven in
2024/2025

This document offers a rich and verified collection of questions and answers for Exam 2 in Instrumental Analysis, covering advanced topics in atomic absorption and emission spectroscopy, mass spectrometry, matrix effects, and surface analysis. It addresses techniques like ICP, AAS, SIMS, XPS, TOF-MS, LIBS, and more. Key themes include matrix matching vs. combining, spectral broadening effects, analyte-matrix interactions, sample introduction in ICP, and various ionization interferences and correction strategies. Also covered are instrumentation mechanisms like hollow cathode lamps, background correction, and the interface between plasma sources and mass analyzers. This is an ideal resource for mastering theoretical principles and practical applications in mid- to upper-level instrumental analysis courses.

Meer zien Lees minder
Instelling
Instrumental Analysis
Vak
Instrumental Analysis










Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Instrumental Analysis
Vak
Instrumental Analysis

Documentinformatie

Geüpload op
6 juni 2025
Aantal pagina's
21
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

Instrumental Analysis Exam 2 questions with
verified answers
Atomic Absorption Spectroscopy Ans✓✓✓ An analytical technique that
uses light absorption to measure the concentration of a metal in a
sample.
Requires flame to atomize samples into ground state atoms.
Atoms absorb characteristic wavelengths from hollow cathode lamps.


Atomic Emission Spectroscopy Ans✓✓✓ A technique in which the
emission of light by thermally excited atoms or ions in a flame, furnace,
or plasma is used to measure concentration.
Requires no lamp.
Intensity proportional to element concentration.
Most common form of atomic spectroscopy.


Atomization Ans✓✓✓ the process of breaking chemical bonds to
decompose a sample into a gas of isolated atoms


Background signal Ans✓✓✓ arises from absorption, emission, or
scatter by everything in the sample besides analyte (the matrix), as well
as from absorption, emission, or scatter by flame, plasma, or furnace.


Characteristic Wavelengths Ans✓✓✓ atoms of each element absorb
and emit light at unique wavelengths

,chemical interference Ans✓✓✓ interference from any component of
the sample that reduces atomization of the analyte. Corrected for by
standard addition method, releasing agents, or protecting agents.


Compare EELS to conventional IR and Raman Spectroscopy. Ans✓✓✓
EELS (electron energy loss spec) consists of a low energy beam of
electrons exciting and scattering off of a sample surface. The energy
loss of some of the scattered electrons is detected and attributed to
vibrational excitation of surface molecules. A vibrational spectrum can
be obtained by plotting the count of energy-loss electrons relative to
elastically scattered electrons against energy which can be used to
identify functional groups and chemical bonds. Advantages include
adequate sample molecule characterization. Limitations include low
resolving power. In contrast, IR spectroscopy excites species with IR
radiation, and the transmitted IR radiation is measured after passing
through the sample to give a vibrational spectrum. Raman spectroscopy
measures the scattered visible radiation after radiation passes through
the sample.


Compare the two most common types of SPM's. Ans✓✓✓ Scanning
tunneling microscope and the atomic force microscope. The STM is a
surface imaging tool based on quantum tunneling of electrons between
surface and STM tip. When conducting tip is brought close to the
surface, bias voltage is applied which causes electrons to tunnel
through the vacuum from the surface to the tip resulting in a tunneling
current that changes with surface height density.

, The AFM consists of a sharp tipped cantilever with a very small tip.
When the tip is close to the surface, forces between tip and surface
lead to deflection of the cantilever according to Hookes law (typically
van der waals forces). Cantilever deflection is measured to get a picture
of the surface.
Advantage of AFM is that it doesn't require conducting samples, and it
has higher resolution. STM can isolate single molecules.
Limitations of STM is that it can only be applied to conducting samples.
For AFM, surface forces may be large enough to damage sample
surface and distort the image.


Describe how it is possible to distinguish between XPS peaks and Auger
electron peaks. Ans✓✓✓ Auger lines are independent of the input
energy because the auger electron energy is independent of the
original photon/electron energy. When comparing spectra produced by
2 x-ray sources, auger lines remain unchanged on the kinetic energy
scale while XPS peaks move.


Describe the changes in state of the metals as they proceed from the
sample container, through the nebulizer and then through the flame.
Ans✓✓✓ In general, the metal molecules are in liquid solutions when
they are introduced into the nebulizer from the sample container via
aspiration. In the nebulizer, nebulization occurs which doesn't affect
the state of matter of the solution but instead turns the solution into an
aerosol of fine droplets. This occurs when an inert Argon gas is flowed
at a high rate through a stream of the solution. This mist is then carried
into the flame with more Argon gas. In the flame, the spray first
evaporates from the heat to leave behind an aerosol containing only
€16,58
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
cracker Chamberlain School Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
2015
Lid sinds
3 jaar
Aantal volgers
1342
Documenten
46956
Laatst verkocht
3 dagen geleden
✨ Cracker – Verified Study Powerhouse

Welcome to your shortcut to academic and certification success. I'm Cracker, a trusted top seller I specialize in high-quality study guides, test banks, certification prep, and real-world exam material all tailored to help you pass fast and score high.

3,8

370 beoordelingen

5
162
4
84
3
53
2
22
1
49

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen