100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

DAVIES BREAST SONOGRAPHY REVIEW ARDMS. EXAM 2025 QUESTIONS AND ANSWERS

Beoordeling
-
Verkocht
-
Pagina's
69
Cijfer
A+
Geüpload op
01-06-2025
Geschreven in
2024/2025

DAVIES BREAST SONOGRAPHY REVIEW ARDMS. EXAM 2025 QUESTIONS AND ANSWERS Which artifact may cause structures to look deeper than they actually are? A. Side lobe B. Shadowing C. Refraction D. Propagation speed error E. Slice thickness - ANS D. propagation speed error The optimum operating frequency for a broad-bandwidth transducer would be: A. 6 MHz B. 7 MHz C. 8 MHz D. 9 MHz E. 10 MHz - ANS C. 8 In breast sonography, which of the following is NOT significantly affected by the limited field of view when imaging superficial structures? A. Contrast resolution 2 | P a g e C o p y r i g h t © 2 0 2 5 T H E B R I G H T A L L R I G H T S R E S E R V E D B. Spatial resolution C. Axial resolution D. Lateral resolution E. Temporal resolution - ANS E. temporal resolution Which of the following affects the actual intensity of the sound utilized for imaging? A. TGC B. Output power C. Overall gain D. Dynamic range E. Harmonics - ANS B. output power The dynamic range of a display is the: A, Number of gray shades B. Depth of focal zone C. Intensity of sound utilized D. Image scale E. Output power - ANS A. number of gray shades 6. Using color/power Doppler while a patient hums to better delineate a mass is called: A. Aliasing B. Spectral mirroring C. Ring-down D. Harmonics E. Fremitus - ANS E. fremitus 3 | P a g e C o p y r i g h t © 2 0 2 5 T H E B R I G H T A L L R I G H T S R E S E R V E D 7. A standoff pad thicker than 1 cm is NOT recommended because it will: A. Make the skin line look thicker than normal. B. Affect the optimal placement of the fixed elevation plane focus. C. Compress the mammary layer and make it look fibrotic. D. Cause enhancement of echoes in the mammary zone. E. Cause decreased penetration and an inability to see the chest wall. - ANS B. affect the optimal placement of the fixed elevation plane focus Which type of transducer does NOT allow the sonographer to vary the focusing capabilities? A. Electronic linear array B. Electronic convex array C. Annular array D. Mechanical sector E. Electronic sector - ANS D. mechanical sector 9. When taking patient history for a breast sonogram, what information from a previous mammogram would NOT be considered relevant? A. Symmetry of breasts B. Location of a questionable lesion C. Size of a questionable lesion D. Date and results of a previous mammogram E. Name of the radiographer - ANS E. Name of radiologist 10. Image amplitude is affected by: A. Power B. Overall gain C. Time gain compensation (TGC)

Meer zien Lees minder
Instelling
ARDMS BREAST REGISTRY
Vak
ARDMS BREAST REGISTRY











Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
ARDMS BREAST REGISTRY
Vak
ARDMS BREAST REGISTRY

Documentinformatie

Geüpload op
1 juni 2025
Aantal pagina's
69
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

DAVIES BREAST SONOGRAPHY
REVIEW ARDMS. EXAM 2025
QUESTIONS AND ANSWERS



Which artifact may cause structures to look deeper than they actually are?
A. Side lobe
B. Shadowing
C. Refraction
D. Propagation speed error

E. Slice thickness - ANS D. propagation speed error


The optimum operating frequency for a broad-bandwidth transducer would
be:
A. 6 MHz
B. 7 MHz
C. 8 MHz
D. 9 MHz

E. 10 MHz - ANS C. 8


In breast sonography, which of the following is NOT significantly affected by the limited field of
view when imaging superficial structures?
A. Contrast resolution


1|P a g e C o p y r i g h t © 2 0 2 5 T H E B R I G H T A L L R I G H T S R E S E R V E D

, B. Spatial resolution
C. Axial resolution
D. Lateral resolution

E. Temporal resolution - ANS E. temporal resolution


Which of the following affects the actual intensity of the sound utilized for imaging?
A. TGC
B. Output power
C. Overall gain
D. Dynamic range

E. Harmonics - ANS B. output power


The dynamic range of a display is the:
A, Number of gray shades
B. Depth of focal zone
C. Intensity of sound utilized
D. Image scale

E. Output power - ANS A. number of gray shades


6.
Using color/power Doppler while a patient hums to better delineate a mass is called:
A. Aliasing
B. Spectral mirroring
C. Ring-down
D. Harmonics

E. Fremitus - ANS E. fremitus


2|P a g e C o p y r i g h t © 2 0 2 5 T H E B R I G H T A L L R I G H T S R E S E R V E D

, 7. A standoff pad thicker than 1 cm is NOT recommended because it will:
A. Make the skin line look thicker than normal.
B. Affect the optimal placement of the fixed elevation plane focus.
C. Compress the mammary layer and make it look fibrotic.
D. Cause enhancement of echoes in the mammary zone.

E. Cause decreased penetration and an inability to see the chest wall. - ANS B. affect the
optimal placement of the fixed elevation plane focus


Which type of transducer does NOT allow the sonographer to vary the focusing capabilities?
A. Electronic linear array
B. Electronic convex array
C. Annular array
D. Mechanical sector

E. Electronic sector - ANS D. mechanical sector


9. When taking patient history for a breast sonogram, what information from a
previous mammogram would NOT be considered relevant?
A. Symmetry of breasts
B. Location of a questionable lesion
C. Size of a questionable lesion
D. Date and results of a previous mammogram

E. Name of the radiographer - ANS E. Name of radiologist


10. Image amplitude is affected by:
A. Power
B. Overall gain
C. Time gain compensation (TGC)

3|P a g e C o p y r i g h t © 2 0 2 5 T H E B R I G H T A L L R I G H T S R E S E R V E D

, D. A and B

E. A, B, and C - ANS E. Power, TGC, Overall gain


11. High-frequency transducers used in breast imaging provide excellent
resolution of breast tissues but limited:
A. Focusing options
B. Gain adjustment
C. Penetration
D. Gray scale

E. Scan lines - ANS C. penetration


2. When using the 123-ABC method of annotation, "B" would indicate:
A. Mass is close to the nipple.
B. Mass is medium shade of gray
C. Mass is in the mammary zone.
D. Mass is benign.

E. Mass requires biopsy. - ANS C. mass is in the mammary zone


13. In the 123-ABC method of annotation, the numbers denote the:
A. Distance from nipple
B. Depth of the mass
C. Number of masses
D. Stage of cancer

E. Sequence of imaging - ANS A. distance from nipple


14. Which method of patient positioning is best for evaluating the medial aspect of the breast?
A. Posterior oblique
4|P a g e C o p y r i g h t © 2 0 2 5 T H E B R I G H T A L L R I G H T S R E S E R V E D

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
Thebright Florida State University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
179
Lid sinds
1 jaar
Aantal volgers
6
Documenten
12718
Laatst verkocht
5 dagen geleden
Topscore Emporium.

On this page, you find verified, updated and accurate documents and package deals.

3,8

36 beoordelingen

5
14
4
10
3
7
2
1
1
4

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen