100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

WMGT 101-22A EXAM 3 QUESTIONS AND ANSWERS 100% PASS

Beoordeling
-
Verkocht
-
Pagina's
14
Cijfer
A+
Geüpload op
12-05-2025
Geschreven in
2024/2025

WMGT 101-22A EXAM 3 QUESTIONS AND ANSWERS 100% PASS AFI 10-245, Antiterrorism - ANS CE shall: have at least 1 engineer at each base must complete Security Eng AT Planning & Design Course, review, document, and track construction projects AT compliance, provide vulnerability assessment protection option program (VAPO) analysis for all critical facilities and off-base leases, and work with the Base Antiterrorism Officer Antiterrorism Requirement Planning - ANS 1. UFC 4-020-01 2. Is only the minimum standard required? 3. Yes: construction standoff distance available? No: UFC 4-020-02 and support manuals 4. If standoff distance is available, apply UFC 4-010-01 and support manuals Design Basis Threat (DBT) - ANS Baseline threat used in the design of protective measures Initial DBT - ANS Based on planning team, local intel and Geographic Combatant Command (COCOM) Theater-Wide threat assessments Modify Initial DBT - ANS Local threat assessments Level of Protection - ANS The degree to which an asset is protected, defines the amount of damage a facility or asset can sustain during an attack ©THESTAR 2025 ALL RIGHTS RESERVED LOP: Very low - ANS Progressive collapse is unlikely, but space in and around damaged area will be unusable and onset of structural collapse occurs. Glazing is likely to be propelled into the building and cause serious injuries. Doors may be propelled into rooms, presenting serious hazards. LOP: Low - ANS Building will not be economically repairable and space in and around damaged area will not be usable, but progressive collapse will not occur. Glazing will fracture and may come out of the frame, but does not present a significant injury hazard. Doors may fail but present minimal hazards. LOP: Medium - ANS Minor damage, space in and around damaged area can be used and will be fully functional after cleanup and repairs. Glazing will fracture but remain in the frame. Doors may stay in frames but will not be reusable. LOP: High - ANS Minimal to no damage with no permanent definitions. Glazing will not break. Doors will be reusable. UFC 4-010-01 - ANS DoD minimum antiterrorism standards for buildings. Intent is to reduce mass casualties, minimize collateral damage to nearby facilities, and facilitate future upgrades and increases FPCON. UFC 4-020-01 - ANS DoD Security Engineering Facility Planning Manual. Acts as a starting point for Garrison Antiterrorism and a quantitative risk-based model. Uses scoring model to evaluate asset value (0-1.0), threat likelihood (0-1.0), and use of minimum AT standards (<0.5). Includes cost data and helps establish a DBT and required LOP. AT/FP misconceptions - ANS 1. Bollards, fences, curbs, and barriers are and adequate substitution for standoff 2. Existing roads must be moved away from existing buildings 3. All building require standoff Mandatory design standards - ANS Standard 1: Standoff distance Standard 6: Progressive collapse

Meer zien Lees minder
Instelling
WMGT 101-22A
Vak
WMGT 101-22A









Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
WMGT 101-22A
Vak
WMGT 101-22A

Documentinformatie

Geüpload op
12 mei 2025
Aantal pagina's
14
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

©THESTAR 2025 ALL RIGHTS RESERVED




WMGT 101-22A EXAM 3 QUESTIONS
AND ANSWERS 100% PASS


AFI 10-245, Antiterrorism - ANS CE shall: have at least 1 engineer at each base must
complete Security Eng AT Planning & Design Course, review, document, and track construction
projects AT compliance, provide vulnerability assessment protection option program (VAPO)
analysis for all critical facilities and off-base leases, and work with the Base Antiterrorism
Officer


Antiterrorism Requirement Planning - ANS 1. UFC 4-020-01
2. Is only the minimum standard required?
3. Yes: construction standoff distance available?
No: UFC 4-020-02 and support manuals
4. If standoff distance is available, apply UFC 4-010-01 and support manuals


Design Basis Threat (DBT) - ANS Baseline threat used in the design of protective measures


Initial DBT - ANS Based on planning team, local intel and Geographic Combatant Command
(COCOM) Theater-Wide threat assessments


Modify Initial DBT - ANS Local threat assessments


Level of Protection - ANS The degree to which an asset is protected, defines the amount of
damage a facility or asset can sustain during an attack

, ©THESTAR 2025 ALL RIGHTS RESERVED

LOP: Very low - ANS Progressive collapse is unlikely, but space in and around damaged area
will be unusable and onset of structural collapse occurs. Glazing is likely to be propelled into the
building and cause serious injuries. Doors may be propelled into rooms, presenting serious
hazards.


LOP: Low - ANS Building will not be economically repairable and space in and around
damaged area will not be usable, but progressive collapse will not occur. Glazing will fracture
and may come out of the frame, but does not present a significant injury hazard. Doors may fail
but present minimal hazards.


LOP: Medium - ANS Minor damage, space in and around damaged area can be used and will
be fully functional after cleanup and repairs. Glazing will fracture but remain in the frame.
Doors may stay in frames but will not be reusable.


LOP: High - ANS Minimal to no damage with no permanent definitions. Glazing will not
break. Doors will be reusable.


UFC 4-010-01 - ANS DoD minimum antiterrorism standards for buildings. Intent is to reduce
mass casualties, minimize collateral damage to nearby facilities, and facilitate future upgrades
and increases FPCON.


UFC 4-020-01 - ANS DoD Security Engineering Facility Planning Manual. Acts as a starting
point for Garrison Antiterrorism and a quantitative risk-based model. Uses scoring model to
evaluate asset value (0-1.0), threat likelihood (0-1.0), and use of minimum AT standards (<0.5).
Includes cost data and helps establish a DBT and required LOP.


AT/FP misconceptions - ANS 1. Bollards, fences, curbs, and barriers are and adequate
substitution for standoff
2. Existing roads must be moved away from existing buildings
3. All building require standoff


Mandatory design standards - ANS Standard 1: Standoff distance
Standard 6: Progressive collapse

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
TheStar Florida State University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
611
Lid sinds
2 jaar
Aantal volgers
179
Documenten
24416
Laatst verkocht
3 dagen geleden
Stuvia Prodigy

Tested, Verified and Updated Study Materials with 100% Guaranteed Success.

3,8

122 beoordelingen

5
58
4
22
3
21
2
4
1
17

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen