100% tevredenheidsgarantie Direct beschikbaar na je betaling Lees online óf als PDF Geen vaste maandelijkse kosten 4.2 TrustPilot
logo-home
Tentamen (uitwerkingen)

KENTUCKY UST CERTIFICATION TEST PREP QUESTIONS |REVISION NOTES |GUARANTEED ACCURATE ANSWERS |LATEST VERSION

Beoordeling
-
Verkocht
-
Pagina's
37
Cijfer
A+
Geüpload op
08-05-2025
Geschreven in
2024/2025

1. when tanks arrive at the job site, how should they be unloaded? - ACCURATE ANSWERS lifted off with a cable attached to the tank lifting lugs As an alternative lifting method, should a cable or chain be wrapped around the tank? - ACCURATE ANSWERS No, Never! When you are lifting a tank, using the lifting lugs, which of these procedures should be followed? - ACCURATE ANSWERS attach a triangle cable through the lugs with no more than a 30 degree angle from the center line. After you unload a new tank on a clean level surface at the job site what else should you do prior to inspection and pre-testing? - ACCURATE ANSWERS Chock the tank to prevent it from Rolling which of the following items should be physically checked for damage or imperfections at the job site? - ACCURATE ANSWERS Piping (steel and fiberglass) Fittings, Vents, Fillboxes, anodes, ECT.. The tanks themselves (ALL OF THE ABOVE)! STI-P3 tanks are delivered with shipping plugs in tank openings. What should be done to these plugs prior to testing? - ACCURATE ANSWERS remove the plugs and replace them with a standard threaded plug that is properly doped should dielectric bushings be installed in all openings of an STI-P3 tank? - ACCURATE ANSWERS yes on all openings what is the maximum air pressure to which a steel tank should be subjected in a pre-installation test? - ACCURATE ANSWERS 5 pounds for fiberglass reinforced plastic (FRP) tank

Meer zien Lees minder
Instelling
Kentucky UST Certification
Vak
Kentucky UST Certification











Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
Kentucky UST Certification
Vak
Kentucky UST Certification

Documentinformatie

Geüpload op
8 mei 2025
Aantal pagina's
37
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

Voorbeeld van de inhoud

KENTUCKY UST CERTIFICATION
TEST PREP QUESTIONS |REVISION
NOTES |GUARANTEED ACCURATE
ANSWERS |LATEST VERSION

1. when tanks arrive at the job site, how should they be unloaded? -
ACCURATE ANSWERS✔✔ lifted off with a cable attached to the tank
lifting lugs


As an alternative lifting method, should a cable or chain be wrapped
around the tank? - ACCURATE ANSWERS✔✔ No, Never!


When you are lifting a tank, using the lifting lugs, which of these
procedures should be followed? - ACCURATE ANSWERS✔✔ attach a
triangle cable through the lugs with no more than a 30 degree angle from
the center line.


After you unload a new tank on a clean level surface at the job site what
else should you do prior to inspection and pre-testing? - ACCURATE
ANSWERS✔✔ Chock the tank to prevent it from Rolling


which of the following items should be physically checked for damage
or imperfections at the job site? - ACCURATE ANSWERS✔✔ Piping
(steel and fiberglass)

,Fittings, Vents, Fillboxes, anodes, ECT..
The tanks themselves
(ALL OF THE ABOVE)!


STI-P3 tanks are delivered with shipping plugs in tank openings. What
should be done to these plugs prior to testing? - ACCURATE
ANSWERS✔✔ remove the plugs and replace them with a standard
threaded plug that is properly doped


should dielectric bushings be installed in all openings of an STI-P3
tank? - ACCURATE ANSWERS✔✔ yes on all openings


what is the maximum air pressure to which a steel tank should be
subjected in a pre-installation test? - ACCURATE ANSWERS✔✔ 5
pounds


for fiberglass reinforced plastic (FRP) tanks up to 12 feet in diameter
what is an acceptable air pressure to which the tanks may be subjected in
a pre-installation test? - ACCURATE ANSWERS✔✔ 3 pounds


for FRP tanks over 12 feet in diameter what is the maximum air pressure
to which the tanks should be subjected in a pre-installation test? -
ACCURATE ANSWERS✔✔ 3 pounds



EXAMLINKS
STUDY SMART,

,when you are conducting an air test on a tank the type of gauge that
should be used is? - ACCURATE ANSWERS✔✔ a pressure gauge with
a maximum limit of 10 to 15 PSIG


the proper procedure for conducting a pre-installation air test of a steel
tank is to? - ACCURATE ANSWERS✔✔ apply 3 to 5 pounds of
pressure and soap all surfaces and weld seams visible through the
coating while inspecting for bubbles.


what is the proper procedure for conducting a pre-installation air test of
an FRP tank Under 12 feet in diameter is to.... - ACCURATE
ANSWERS✔✔ apply 3 pounds of air pressure and soap all surfaces
while inspecting for any sign of a leak either audible or visible in the
form of bubbles on the surface


a double-walled steel tank build in accordance with UL standard 58 is? -
ACCURATE ANSWERS✔✔ requires air testing of the interstitial space
prior to installation


the proper procedure for conducting a pre-installation air test of a
double-walled tank is to? - ACCURATE ANSWERS✔✔ pressurize the
inner tank monitor the pressure for one hour and then pressurize the
space between the inner and outer tanks with the air from the inner tank




EXAMLINKS
STUDY SMART,

, when shipped a steel tank is covered with a coating that is an important
part of the tanks Corrosion Prevention system. "holidays" which show
up in the coating at the installation site should? - ACCURATE
ANSWERS✔✔ should be touched up with a compatible coating after
proper surface preparation


touch up of holidays in a steel tank coatings at the installation site
should be done....... - ACCURATE ANSWERS✔✔ according to the
manufacturer's instructions


dielectric bushings are usually made of what? - ACCURATE
ANSWERS✔✔ non-metallic material


factors to consider in determining the size shape and depth of a tank
excavation include what? - ACCURATE ANSWERS✔✔ *the tank
manufacturers recommendations
*the requirements for compacting bedding and backfill as well as
stability of the soil
*the depth of cover


AKA all of the above


in the absence of local requirements the recommended minimum
distance between a tank excavation and adjacent structures or property
lines is how many feet? - ACCURATE ANSWERS✔✔ 5 feet

EXAMLINKS
STUDY SMART,
€17,05
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
EXAMLINKS West Virginia University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
55
Lid sinds
1 jaar
Aantal volgers
6
Documenten
3391
Laatst verkocht
2 dagen geleden
ECONOMICS|NURSING|BIOLOGY |BUSINESS |LAW EXAMS |STUDY NOTESLATEST AND UPDATED .

On this page, you find all documents, package deals, and flashcards offered by seller EXAMLINKS.

3,0

16 beoordelingen

5
3
4
4
3
3
2
2
1
4

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen