PROPANE PRACTICE TESTS EXAM
WITH COMPLETE SOLUTIONS

According to the Two Permanent Openings Method one opening must commence within
____ and one must commence within ___ of the enclosure - ANS12 inches of the top 12
inches of the bottom

Room heaters shall NOT be installed in what occupancies? - ANSHealth care and
Residential board and care.

Define a type B-W gas vent: - ANSIt shall not have a listed capacity NOT LESS than
that of the listed vented wall furnace to which it is connected.

Listed vented wall furnaces shall use which type of venting system? - ANSType B-W
gas vent

NO portion of a venting system shall extend or pass through any.... - ANSFabricated air
duct OR Furnace plenum

The exit terminals of mechanical draft systems shall not be LESS than ___________
when located adjacent to public walkways. - ANS7 ft above finished ground level

Forced draft systems and all portions of induced draft systems under positive pressure
during operation shall be designed and installed so as to _____________. -
ANSPrevent leakage of flue gases into the building

Mechanical draft systems shall be _______ . - ANSListed

A chimney for residential type or low heat appliances shall extend at least 2 feet higher
than any portion of a building within a horizontal distance of _______. - ANS10 feet

Category I Vented appliance - ANSAn appliance that operates with a non-positive vent
static pressure and with a vent gas temperature that avoids excessive condensate
production in the vent.

Type 1 and Type 2 clothes dryers shall be exhausted to the ________. - ANSOutside

Ventilating hoods and exhaust systems shall be ________ installed in commercial
applications and to vent industrial equipment. - ANSPermitted to vent gas appliances

, What appliances are NOT required to be vented? - ANSCounter appliances or Direct
gas-fired make-up air heaters

What is the correct spacing of supports for 3/4" or 1" steel pipe? - ANSEvery 8 feet

Regarding indoor combustion air, what method states the minimum volume shall be 50
cube feet per 1000 Btu/hour? - ANSStandard method

All dispensers shall be installed on what type of foundation? - ANSConcrete

The number of containers in a building undergoing minor renovations shall NOT exceed
the ________ assigned to using the LP-gas. - ANSNumber of workers and shall not
exceed ______ lbs in size

Aboveground containers shall be ________. - ANSPainted

All regulators for outdoor installations shall be designed, _______ or protected so that
operation will not be affected by the elements. - ANSInstalled

Temperature sensitive elements of emergency shutoff valves shall NOT be ________ . -
ANSPainted

In a piping system where condensation of vapor can occur, piping shall be _______, or
means shall be provided for re-vaporizing the condensate. - ANSsloped back to the
container

What is the minimum cover that should be maintained over all underground metallic
piping? - ANS12 inches

Polyethylene piping systems shall be limited to vapor service not exceeding ________. -
ANS30 psig

A listed __________ shall be installed at the discharge end of the transfer hose at
vehicle fuel dispensers. - ANSQuick-acting shutoff valve

Metallic pipe joints shall be permitted to be ____________ using proper pipe and
fittings. - ANSWelded or Brazed

Flexible metallic connectors shall NOT exceed _________ in overall length when used
with liquid or vapor piping on stationary containers of 2000 gallon w.c. or less. - ANS5
feet

Hose length at a motor fuel dispensing station may NOT exceed _____________
unless approved by AHJ. - ANS18 feet

Geschreven voor

Instelling
PROPANE PRACTICE
Vak
PROPANE PRACTICE

Documentinformatie

Geüpload op
3 mei 2025
Aantal pagina's
15
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

€15,99
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Online lezen of als PDF
Geen vaste maandelijkse kosten

Maak kennis met de verkoper
Seller avatar
TaylorJones02

Maak kennis met de verkoper

Seller avatar
TaylorJones02 Oxford College Of Emory University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
-
Lid sinds
11 maanden
Aantal volgers
0
Documenten
84
Laatst verkocht
-

0,0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Populaire documenten

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen