More NICET LEVEL 1 questions
A system that allows an alarm to be received from either side of a single ope - answer
Class A
primary purpose of a duct smoke - answerto prevent the spread of smoke within the
building
Horns, Strobes, Bells, and speakers are connected to what type of circuit - answer
Notification appliance circuit
that all wiring is electronically monitored for disarrangement or break in cabling system -
answer supervised wiring
indicate that the unit is electrically safe and meets UL product standards - answerUL
listing
provide requirements for the type of fire alarm systems in a particular occupancy type or
use group - answerIBC
has ability to enforce codes and standards adopted jurisdiction - answerfire inspector
A protected premises fire alarm system requires - hours of standby power and an
additional - minutes of alarm capacity - answer24-5
in building fire emergency voice/alarm communications system hours standby and
minutes of alarm - answer24-15
in buildings with mass notification hours standby and minutes of alarm - answer24-15
Wide area building Mass Notification - answer7 days 60 minutes
garage attic and kitchen - answerareas where a smoke detector should not be used
impaired suppression system is a - answersupervisory
a fail safe class wiring system - answerclass d
dedicated branch circuit, Disconnecting means marked as Fire Alarm Circuit,
disconnecting means must be marked red in color - answerFire Alarm Primary Power
Supply
, the entire lens of a visible notification appliance must be mounted between - inches and
- inches - answer80/96
Smoke detectors listed to UL 268 must actuate before the smoke density in the test box
reaches - percent per foot obstruction - answer4
8 1/2 X 11 - answerA
11 X 17 - answerB
17 X 22 - answerC
22 X 34 - answerD
34 X 44 - answerE
thinest line weight - answerdimension line
it supplements drawings and has equal value - answerspecifications
nfpa life safety code 101, international building code (IBC), NFPA 72 national fire alarm
and signaling code, nfpa 70 (nec) nfpa 90, nfpa1221 - answercodes applicable to fire
alarm systems
what is not depicted on a floor plan - answersound pressure level appliances
a floor plan is a view of a slice of the building drawn to exact scale - answerhorizontal
a point to point wiring diagram shows the interconnection of various devices to the
terminal connections in the - answerfire alarm control panel
an architects scale is used by the fire service during plans review to - answercheck for
proper spacing of initiating fire alarm devices
what section of master spec applies to fire alarm systems - answerdivision 28
standard that provides requirements for fire safety symbols - answernfpa179
drawing type that is used to indicate code compliance and not intended for installation -
answerconcept design
a circuit in which 2 or more resistors are connected end to end so that the current has
but on path to flow - answerseries circuit
a circuit in which to or more resistors are connected between two common points so
that the current has two or more paths in which to flow - answerparallel circuit
A system that allows an alarm to be received from either side of a single ope - answer
Class A
primary purpose of a duct smoke - answerto prevent the spread of smoke within the
building
Horns, Strobes, Bells, and speakers are connected to what type of circuit - answer
Notification appliance circuit
that all wiring is electronically monitored for disarrangement or break in cabling system -
answer supervised wiring
indicate that the unit is electrically safe and meets UL product standards - answerUL
listing
provide requirements for the type of fire alarm systems in a particular occupancy type or
use group - answerIBC
has ability to enforce codes and standards adopted jurisdiction - answerfire inspector
A protected premises fire alarm system requires - hours of standby power and an
additional - minutes of alarm capacity - answer24-5
in building fire emergency voice/alarm communications system hours standby and
minutes of alarm - answer24-15
in buildings with mass notification hours standby and minutes of alarm - answer24-15
Wide area building Mass Notification - answer7 days 60 minutes
garage attic and kitchen - answerareas where a smoke detector should not be used
impaired suppression system is a - answersupervisory
a fail safe class wiring system - answerclass d
dedicated branch circuit, Disconnecting means marked as Fire Alarm Circuit,
disconnecting means must be marked red in color - answerFire Alarm Primary Power
Supply
, the entire lens of a visible notification appliance must be mounted between - inches and
- inches - answer80/96
Smoke detectors listed to UL 268 must actuate before the smoke density in the test box
reaches - percent per foot obstruction - answer4
8 1/2 X 11 - answerA
11 X 17 - answerB
17 X 22 - answerC
22 X 34 - answerD
34 X 44 - answerE
thinest line weight - answerdimension line
it supplements drawings and has equal value - answerspecifications
nfpa life safety code 101, international building code (IBC), NFPA 72 national fire alarm
and signaling code, nfpa 70 (nec) nfpa 90, nfpa1221 - answercodes applicable to fire
alarm systems
what is not depicted on a floor plan - answersound pressure level appliances
a floor plan is a view of a slice of the building drawn to exact scale - answerhorizontal
a point to point wiring diagram shows the interconnection of various devices to the
terminal connections in the - answerfire alarm control panel
an architects scale is used by the fire service during plans review to - answercheck for
proper spacing of initiating fire alarm devices
what section of master spec applies to fire alarm systems - answerdivision 28
standard that provides requirements for fire safety symbols - answernfpa179
drawing type that is used to indicate code compliance and not intended for installation -
answerconcept design
a circuit in which 2 or more resistors are connected end to end so that the current has
but on path to flow - answerseries circuit
a circuit in which to or more resistors are connected between two common points so
that the current has two or more paths in which to flow - answerparallel circuit