ARMY ELECTRICAL EXPLOSIVES SAFETY (AMMO28) EXAM QUESTIONS AND ANSWERS

Instelling
ARMY ELECTRICAL EXPLOSIVES SAFETY E
Vak
ARMY ELECTRICAL EXPLOSIVES SAFETY E

Voorbeeld van de inhoud

ARMY ELECTRICAL EXPLOSIVES SAFETY (AMMO28)
EXAM 2025-2026 QUESTIONS AND ANSWERS
Which material is preferred for ground conductors? - ANSWER--Copper


What does n represent in the Basic Bonding Formula? - ANSWER--Number of down conductors


What does Km represent in the Basic Bonding Formula? - ANSWER--flashover medium




During an LPS inspection you notice a grounded metal pipe 3 feet from a conductor. Should you write it
up as a possible discrepancy? - ANSWER--Yes.




Grounded metal objects within 6 feet of a conductor should be considered for bonding




What does D represent in the Basic Bonding Formula? - ANSWER--Bonding distance




Which bonding condition applies to isolated metal objects surrounded by non- conductive material
(such as a metal door frame in a concrete wall)? - ANSWER-- WRONG Condition 2




Calculate the BBF to determine if bonding is required for the scenario below. Use a calculator, the BBF
equation aid, and the bonding job aid as required.
• The metal vent is 15 feet high.
• There are 2 down conductors at the proper spacing.
• The vent is 12 inches (1 foot) from a conductor through air. - ANSWER--Bonding distance for the
metal roof vent is 1 foot 8 inches. Bonding is required.

,LPS test results must be kept on file for - ANSWER--6 inspection cycles




An LPS visual inspection is required every - ANSWER--12 months




Conductive floors in explosives facilities must be tested every - ANSWER--WRONG 6 months




At a minimum, how many individual resistance tests must be performed on this conductive floor? Refer
to DA PAM 385-64, Section C-3 as required. - ANSWER-- Ten tests: five electrodeto-electrode and five
electrode-to-ground tests


An LPS requires three-point fall-of-potential earth resistance testing every - ANSWER--Every 24
months




When conducting a 3-point fall-of-potential earth resistance test, what is the maximum allowable
resistance reading? - ANSWER--25 ohms




When conducting a bonding resistance test, what is the maximum allowable reading? - ANSWER--1 ohm




How many individual bonding resistance tests are required on an integral LPS with 12 air terminals and 2
down conductors? - ANSWER--24




Which storm warning system measures the strength of atmospheric electric fields and warns of the
possibility of lightning strikes? - ANSWER--Pre-strike

, Which hazardous classified location division poses the least probability of ignition or explosion? -
ANSWER--Division 2




Which material belongs to hazardous classified location Class II? - ANSWER--coal dust




Which material belongs to hazardous classified location Class I? - ANSWER-- acetylene gas




Which HERO classification describes items that may explode or detonate if exposed to EMR? - ANSWER--
HERO UNSAFE




Which of the following is NOT a hazard posed by electromagnetic radiation? - ANSWER--
WRONG ignition of fuel and other combustibles
WRONG generation of extreme heat in the human body




For guidance on lightning protection requirements, you use AFI 32-1065 and - ANSWER--NFPA 780




You need to inspect an LPS that has vertical poles connected to overhead cables that stretch the length
of the structure. What type of LPS does this describe? - ANSWER--catenary




How many feet radius does the DoD require for an LPS zone of protection? - ANSWER--100ft




While conducting an LPS inspection, you discover the scenario illustrated in the image below. Do you
write it up as a discrepancy? - ANSWER--yes, because the air terminal is not attached to a conductor.

Geschreven voor

Instelling
ARMY ELECTRICAL EXPLOSIVES SAFETY E
Vak
ARMY ELECTRICAL EXPLOSIVES SAFETY E

Documentinformatie

Geüpload op
7 april 2025
Aantal pagina's
22
Geschreven in
2024/2025
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

€9,14
Krijg toegang tot het volledige document:

100% tevredenheidsgarantie
Direct beschikbaar na je betaling
Lees online óf als PDF
Geen vaste maandelijkse kosten


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
dennohz2000 Teachme2-tutor
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
222
Lid sinds
2 jaar
Aantal volgers
47
Documenten
5308
Laatst verkocht
1 dag geleden

4,1

56 beoordelingen

5
34
4
8
3
6
2
2
1
6

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Veelgestelde vragen